RF INDUSTRIES RFT-1200 Coax Connector Instruction Manual

June 13, 2024
RF Industries

RF INDUSTRIES RFT-1200 Coax Connector

Parts

  • BODY

  • PIN

  • CLAMP

  • GASKET

  • WASHER

  • BACK NUT

ASSEMBLY INSTRUCTIONS

STEP 1

STEP 2

STEP 3

STEP 4

Step 1:

Cut end of cable evenly. Strip cable to dimensions shown on outline drawing. All cuts are to be clean and square. Do not nick braid, dielectric or center conductor. Slide back nut, washer and gasket onto cable. Braid must be combed for assembly of clamp.

Step 2:

Place the clamp over braid and push clamp back against cable Jacket. Fold back braid wire and form over the clamp evenly. Trim extra braid If needed.

Step 3:

Slide pin onto center conductor until it yields against the cable dielectric. Pre tin cable conductor if using stranded cable {if needed). Solder or crimp pin in place. If soldering use minimum amount of heat.

Step 4:

Snug gasket against the clamp. Insert pin, cable and hardware Into the body. Tighten back nut while holding body stationary.

Customer Support

RF CONNECTORS

7610 Miramar Road, San Diego, CA 92126-4202 – 858-549-6340
800-233-1728 – Fax 858-549-6345 E-mail: rfi@rfindustries.comwww.rfindustries.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals