RF Industries RP-3000-1C Coax Connector Instruction Manual
- June 13, 2024
- RF Industries
Table of Contents
**RF Industries RP-3000-1C Coax Connector Instruction Manual
**
Parts List
Assembly Instructions
Step 1: Cut end of cable evenly. Strip cable to dimensions shown in catalog or on envelope/outline drawing. All cuts are to be clean and square. Do not nick braid or center conductor when cutting. Slide ferrule over cable. If using strain relief or heat shrink tubing slide onto cable first.
Step 2: Pre tin cable conductor if using stranded cable (if needed). Slide contact onto center conductor until it yields against the cable dielectric. Solder contact in place.
Step 3: Slide ferrule stud under braid, while inserting the contact into the body.
Step 4: Slide the ferrule over the braid until it yields against the back of the connector. Crimp the ferrule with crimp tool as specified on connector drawing. Trim any extra braid extending out of ferrule end.
RF CONNECTORS
7610 Miramar Road, San Diego, CA 92126-4202 –
858-549-6340
800-233-1728 Fax
858-549-6345 E-mail: