JONES STEPHENS Plumbite Push Water Heater Connector Instructions
- June 13, 2024
- JONES STEPHENS
Table of Contents
JONES STEPHENS Plumbite Push Water Heater Connector
PLUMBITE® PUSH WATER HEATER CONNECTOR
For use with water in accessible locations only
-
For a proper water-tight fit, use a deburring tool to remove burrs. Use a sand cloth to obtain a smooth edge to pass by the rubber seal of fitting without damage. The tube must be round and free of scratches and imperfections.
-
Make Install Depth mark on the outside of the pipe at 1-1/16” (27 mm) from the end to help ensure
proper installation. -
Remove and discard the included inner plastic stiffener when using the fitting with Copper and CPVC installations. Use the disconnect tool (sold separately) to remove the stiffener same as if you are removing pipe/tubing (described below).
To Remove: Snap removal tool (sold separately) over pipe/tubing. While firmly pressing the removal tool against the plastic collar at the fitting opening, carefully slide pipe/tubing in the opposite direction out of the fitting. Operate at temperatures from 0 to 180°F (82°C) at a maximum working pressure of 200 PSI (1379 kPa)