Configuration examples for redundant transmission systems.

Double exciter

This system is composed of 2 exciters A and B, in which one is ON and the other is OFF. In case the unit that is on fails, it will be replaced by the second unit.

Double exciter ransmitters System
Broadcast Systems FM Stations

“1+1R” Passive system transmitters

This system is composed of 2 transmitters, A and B, in which 1 is ON and is connected to the antenna and the second is OFF and is connected to the dummy load. Incase the operating transmitter fails, it is immediately replaced with the second unit.

Double excitersystem

“1+1R” Active system transmitters

This system is composed of 2 transmitters, A and B, in which 1 is ON and is connected to the antenna and the second is OFF and is connected to the dummy load. In case the operating transmitter fails, it is immediately replaced with the second unit.
Active system transmitters

“6+1R” Active system transmitters

This system is composed of “N” transmitters connected to the antenna and 1 transmitter used as back-up unit that is connected to the dummy load.In case one of the “N” transmitters fails it is immediately replaced with the back-up unit and the faulty unit is switched to the dummy load.

Active system transmittersActive system
transmitters

R.V.R. Elettronica S.r.l.