R V R VJ5000 Tube Amplifiers Owner’s Manual

June 13, 2024
R V R

R V R VJ5000 Tube Amplifiers

Product Information

Tube Amplifiers
The Tube Amplifiers family VJ series includes the following models:

  • VJ5000
  • VJ12000
  • VJ8000
  • VJ15000
  • VJ10000
  • VJ20000

Features of the Tube Amplifiers include:

  • Tuning motorized for input, plate, and load, able to cover the entire band from 87.5 to 108 MHz.
  • High impedance for the low-pass filter.
  • High overall efficiency.
  • Possibility of Remote Control.
  • Measuring is extremely accurate for the forward and reflected power.
  • Electronic start timing with Time Saving.
  • Power amplifier on extractable undercarriage, in order to facilitate transportation and maintenance.
  • Meets or exceeds all FCC and CCIR requirements.
  • Protections against excessive VSWR, grid current, temperature, safety interlocks, inadequate ventilation, and unbalanced AC line.
  • No neutralization is required.
  • Visualization of the intervention number.

Product Usage Instructions

To use the Tube Amplifiers, follow these instructions:

  1. Connect the RF Input using a 1 + 5/8 EIA flange-type connector with a 50 ohm impedance.
  2. Connect the RF Output using an N or 7/16 EIA Flange connector with a 50 ohm impedance.
  3. Connect the RF Monitor for monitoring purposes.
  4. Connect the Interlock Output to provide an interlock signal to external devices.
  5. Connect the Interlock Input to receive an interlock signal from external devices.
  6. Ensure the ambient working conditions meet the specified requirements.
  7. Make sure the cooling system is functioning properly.

Note : The specific technical specifications for each model of the Tube Amplifiers can be found in the user manual. Please refer to the manual for detailed information on power output, frequency range, tube type, input power, primary power, AC power consumption, physical dimensions, weight, connectors, and standard compliance.

Features

  • Tuning motorized for input, plate, and load able to cover the entire band from 87,5 to 108 MHz.
  • High impedance for the low-pass filter.
  • High overall efficiency.
  • Possibility of Remote Control.
  • Measuring is extremely accurate for the forward and reflected power.
  • Electronic start timing with Time Saving.
  • Power amplifier on the extractable undercarriage, in order to facilitate transportation and maintenance.
  • Meets or exceeds all FCC and CCIR requirements.
  • Protections against excessive VSWR, grid current, temperature, safety interlocks, inadequate ventilation, and unbalanced AC lines.
  • No neutralization is required.
  • Visualization of the intervention number.

R.F. Power Amplifiers 87,5 – 108 MHz

Technical specifications

Parameters| Values|  |
---|---|---|---
GENERALS
Rated output power| 5000 – 5500 W| 8000W| 10000 – 11000W
Frequency Range| FCC -CCIR and other on-request
Tube| EIMAC 3CX3000A7 Triode| EIMAC YU-148 Triode| EIMAC 3CX15000A7 Triode
Input power for rated output| 300 W| 500 W
Primary Power| 400 VAC ±15% 3 phases Y, 230VAC ±15% 3 phases
AC Power Consumption

(depending on configuration)

| Approx, 9.5 kW| Approx, 16 kW| Approx. 19 kw
Phisical Dimensions (W x H x D)| 565 x 850 x 1800 mm| 565 x 850 x 1930 mm
Weight| Approx. 430 Kg| Approx 490Kg| Approx 650Kg
Ambient Working Conditions|
Cooling|
CONNECTORS
RF Input|  | N or 7/16 EIA Flange, 50 ohm
RF Output| 1 + 5/8″ EIA flange type, 50 ohm
RF Monitor|
Interlock Output|
Interlock Input|
STANDARD COMPLIANCE


Safety

| EN 60215:1989

EN60215/A1:1992-07 EN60215/A2:1994-09

EMC| EN 301 489-1 V1.4.1 (2002-08)

EN 301 489-11 V1.2.1 (2002-11)

All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

Values Values Values

12000 – 13000W| 15000 – 16000W| 20000 – 25000W
FCC -CCIR and other on-request
EIMAC 3CX15000A7 Triode| EIMAC 3CX15000A7 Triode| 3CX15000A7 Triode
600 W| 750 W| 1000 W
400 VAC ±15% 3 phases Y, 230VAC ±15% 3 phases D
Approx. 21 kW| Approx. 30 kW| Approx. 39 kW
565 x 850 x 1930 mm| 1130 x 850 x 1930 mm
Approx. 620 Kg| Approx 640 Kg| 2 cabinet Approx. 750Kg

N or 7/16 EIA Flange, 50 ohm| 7/16 EIA Flange, 50 ohm
1 + 5/8″ or 3 + 1/8 EIA flange type, 50 ohm| 3 + 1/8 EIA flange type, 50 ohm

EN 60215:1989

EN60215/A1:1992-07 EN60215/A2:1994-09

EN 301 489-1 V1.4.1 (2002-08)

EN 301 489-11 V1.2.1 (2002-11)

Ordering information

Options for VJ
Code

  • MP-VJ
  • ST-VJTRIODE
  • TLC-VJ

Description

  • Available only for VJ5000, VJ8000, and VJIOOOO models.
  • Filament voltage stabilizator
  • Version with LCD display on front panel, able to manage the telemetry

RVR Elettronica S.p.A.
• 40138 Bologna • Italy Phone: +39 051 6010506 • Fax: +39 051 6011104 e-mail: [email protected] • web: http://www.rvr.it

References