  • The product is a 32-inch (81.3 cm) appliance that requires both an electrical and gas connection. It is important to follow the installation guidelines provided in the user manual to ensure proper usage and compliance with local code requirements.

Side View Worktop Details

  • The side view of the worktop provides important information about the dimensions and layout of the appliance. It helps in understanding the placement and connection requirements.

Leg Details

  • The leg details section provides information about the support structure of the product. It is important to ensure that the legs are properly installed and provide stable support for the appliance.

Front View

  • The front view of the appliance provides a visual representation of how it looks from the front. This can be helpful in determining the location of control panels or other features.

Rear View

  • The rear view of the appliance provides information about the backside of the product. This can be useful for understanding the placement of gas connections or other components.

Product Usage Instructions

Before proceeding with the installation, make sure to follow these guidelines:

  1. Ensure that a properly-grounded horizontally mounted electrical receptacle is installed no higher than 3 inches (7.6 cm) above the floor.
  2. The electrical receptacle should be located no less than 2 inches (5 cm) and no more than 8 inches (20.3 cm) from the left side (facing the product).
  3. Check all local code requirements to ensure compliance.
  4. Install an agency approved, properly sized manual shut-off valve at a maximum height of 3 inches from the floor.
  5. The shut-off valve should be located no less than 2 inches and no more than 8 inches from the right side (facing the product).
  6. Use an approved shut-off valve and regulator gas connection, along with a properly sized flex or rigid pipe.
  7. Check all local code requirements to ensure compliance.

Note: It is important to follow the electrical and gas connection guidelines provided in the user manual for safe and proper usage of the product.

Dimension

BERTAZZONI-9021-MAS365DFMXV-36-inch-Dual-Fuel-Range-
FIG-1

INSTALLATION

  • A properly-grounded horizontally mounted electrical receptacle should be installed no higher than 3” (7.6 cm) above the floor, no less than 2” (5 cm) and no more than 8” (20,3 cm) from the left side (facing product). Check all local code requirements.
  • Install agency approved, properly sized manual shut-off valve at max. height of 3” from floor, 2” min. height/ 8” max. height from the right side (facing product). Use approved shut-off valve & regulator gas connection, properly sized flex or rigid pipe. Check all local code requirements.BERTAZZONI-9021-MAS365DFMXV-36-inch-Dual-Fuel-Range-FIG-2

NOTE

  • a. Electrical Connection
    • b. Gas Connection