Product Specification
Main SPEC
CPU | Qualcomm IPQ8072A |
---|---|
Wi-Fi 2.4GHz RF | Qualcomm QCN5024 |
Wi-Fi 5GHz RF | Qualcomm QCN5054 |
SPI NOR Flash | • 8MB |
NAND Flash | • 512MB |
RAM | DDR4 1GB |
• 512MB DDR4*2
Wi-Fi RF PA/FEM| 2.4GHz FEM:QPF4288A (Board data use QPF4228 for lower power)
5GHz FEM:QPF4588A(Board data use QPF4528 for lower power)
antenna| 4x Dual band
PD IC| MP8009
Ethernet| QCA8081
Console| Prolific PL2303G4ZJG8P2
TPM| Infineon SLB 9670VQ2.0
Internal connector| M.2 Connector
Key parts
CPU | Qualcomm IPQ8072A |
---|---|
Wi-Fi 2.4GHz RF | Qualcomm QCN5024 |
Wi-Fi 5GHz RF | Qualcomm QCN5054 |
SPI NOR Flash | • 8MB |
NAND Flash | • 512MB |
RAM | DDR4 1GB |
• 512MB DDR4*2
Wi-Fi RF PA/FEM| 2.4GHz FEM:QPF4288A (Board data use QPF4228 for lower power)
5GHz FEM:QPF4588A(Board data use QPF4528 for lower power)
antenna| 4x Dual band
PD IC| MP8009
Ethernet| QCA8081
Console| Prolific PL2303G4ZJG8P2
TPM| Infineon SLB 9670VQ2.0
Internal connector| M.2 Connector
Housing design & dimension:
LED definition
Description (For Alpha/Beta/Charlie/Delta) | LED |
---|---|
AP is off or reboot started | Off |
Normal Operation | Solid Green |
AP is booting & connecting to wireless controller | Flashing Green |
Error, no wireless controller found. AP will
reboot (if not yet claimed by a controller). Check
network connection if error persists.
If reset button pressed: AP preparing configuration rese
Solid Red| Solid Red
Configuration reset in progress | Flashing Slow Red
Firmware update in progress
Note: Do not disconnect from power| Flashing Fast Red
AP has no connection to the wireless controller| Solid Ambe
AP is not claimed by wireless controller| Flashing Amber
Safety Instructions
You can operate the access point (AP) safely if you follow the information in
these Safety Instructions and on the appliance.
Do not reach into the appliance. There are dangerous circuits inside the
appliance that can cause death if you touch them.
Damaged appliances must be returned. It is forbidden to open the hardware
appliance or to change its components. Failure to comply with this rule
results in the loss of warranty cover from EDIMAX.
Connect the device to a power socket with a fully functional earth conductor.
Defective earth conductor connections do not comply with the requirements for
safety and electromagnetic compatibility. Check the power socket before
connecting the hardware appliance.
The socket-outlet shall be installed near the equipment and shall be easily
accessible.
Before you switch on the appliance make sure that your mains voltage complies
with the supply voltage of the appliance. The connection data are shown on the
name plate.
To disconnect the appliance completely take the power cable from the power
socket. Make sure that the power plug is freely accessible.
Make sure that no one can trip over the power cable and that it cannot be
damaged by objects.
Only connect system peripherals complying with the requirements for protective
extra-low voltage according to EN/IEC 62368-1.
Only use parts and accessories validated by EDIMAX. Using non-approved parts
and accessories may affect the functioning of the appliance and your safety.
The appliance produces heat. Ensure that there is sufficient air circulation
to remove the heat.
Avoid a permanent high level of air humidity and formation of condensation.
Protect the appliance from humidity and chemicals. Safe use of the appliance
is no longer possible if: the chassis is damaged water penetrated the
appliance objects entered the appliance via air opening smoke comes out of
the appliance the power cable is damaged it does not work properly Immediately
turn off the appliance in the event of one of the above problems, remove the
power cable
from the power socket and contact your customer service as soon as possible.
We expressly exclude any product liability and warranty claims if the
appliance is not operated according to the instructions in these notes and to
the notes attached to the appliance itself.
PoE-Injector Safety Information
Caution: The PoE injector is to be connected only to PoE networks without
routing to the outside plant.
ÌAC Power Cord: The power cord must have regulatory agency approval for the
specific country in which it is used (for example, UL, CSA, VDE, GS, etc.).
The power cord must be a three-conductor type (two current carrying
conductors; one ground conductor terminated on one end by an IEC 60320
appliance coupler (for connection to the PoE-Injector), and on the other end
by a plug containing a ground (earthing) contact).
The power cord must be razed for a minimum of 250 VAC RMS operation, with a
minimum rated current capacity of 5 A (or a minimum wire gauge of 18 AWG (0.75
mm2)). \
A PoE-Injector installed in Australia requires power cords with a minimum wire
gauge of 16 AWG (1.0 mm2).
The PoE-Injector “Data In” and “Data & Power Out” ports are shielded RJ45 data
sockets. They cannot be used as Plain Old Telephone Service (POTS) telephone
sockets. Connect RJ45 data connectors only to those sockets.
The AC wall socket-outlet must be near the PoE-Injector and easily accessible.
You can remove AC
power from the PoE-Injector by disconnecting the AC power cord from either the
wall socket-outlet or the PoE-Injector appliance coupler.
The PoE-Injector “Data In” and “Data & Power Out” interfaces are qualified as
Safety Extra-Low Voltage (SELV) circuits according to IEC 62368-1. Connect
these interfaces only to SELV interfaces on other equipment.
Warnings
Connect the PoE-Injector only to the IP device with which it was bought. Using
the PoE-Injector with other IP devices can cause damage to the IP device.
Read the installation instructions before connecting the PoE-Injector to its
power source.
Follow basic electricity safety measures whenever connecting the PoE-Injector
to its power source.
A voltage mismatch can cause equipment damage and may pose a fire hazard. If
the voltage indicated on the label is different from the power outlet voltage,
do not connect the PoE-Injector to that power outlet.
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
This device meets all the other requirements specified in Part 15E, Section
15.407 of the FCC Rules.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 51.5cm between the radiator & your body.
Note: The country code selection is for non-US model only and is not
available to all US model. Per FCC regulation, all WiFi product marketed in US
must fixed to US operation channels only.
FCC regulations restrict the operation of this device to indoor use only.
O The operation of this device is prohibited on oil platforms, cars, trains,
boats, and aircraft, except that operation of this device is permitted in
large aircraft while flying above 10,000 feet.
O Operation of transmitters in the 5.925-7.125 GHz band is prohibited for
control of or communications with unmanned aircraft systems.
Industry Canada statement
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Caution
a. Operation shall be limited to indoor use only;
b. Operation on oil platforms, cars, trains, boats and aircraft shall be
prohibited except for on large aircraft flying above 10,000 ft.
Radiation Exposure Statement
This equipment complies with ISED radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
greater than 30.5cm between the radiator & your body.
RED Compliance Statement
Compliance with 2014/53/EU Radio Equipment Directive (RED)
In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table
provides information on the frequency bands used and the maximum RF transmit
power of the product for sale in the EU:
Frequency Range (MHz) | Max. Transmit Power (dBm) EIRP |
---|---|
2412 ~ 2472 | 19.96 dBm |
5180 ~ 5240 | 22.95 dBm |
5250 ~ 5320 | 22.93 dBm |
5500 ~ 5700 | 29.99 dBm |
5945 ~ 6425 | 22.98 dBm |
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
| AT| BE| BG| HR| CY| CZ| DK
---|---|---|---|---|---|---|---
EE| FI| FR| DE| EL| HU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK(NI)
This device is restricted to indoor use
Declaration of Conformity
We, Edema Technology Co., Ltd., declare under our sole responsibility, that
the equipment described below complies with the requirements of the European
Radio Equipment directives.
Equipment: Access Point
Model No.: EW-7889WAX, EW-7899WTX
The following European standards for essential requirements have been
followed:
Directives 2014/53/EU
Spectrum : EN 300 328 V2.2.2 (2019-07) EN 301 893 V2.1.1 (2017-05) Draft EN
303 687 V1.0.1 (2022-09)
EMC : EN 301 489-1 V2.2.3 (2019-11) EN 301 489-17 V3.2.4 (2020-09)
EMF : EN IEC 62311: 2020 EN 50665: 2017\
Safety (LVD) : IEC 62368-1:2014 (2nd Edition) and/or EN 62368-1:2014+A11:2017
Edimax Technology Europe B.V.
Fijenhof 2,
5652 AE Eindhoven,
The Netherlands
Date & Place of Issue: 31/May/2022, Eindhoven
Signature:
Printed Name: David Huang
Title: Director
a company of:
Edimax Technology Co., Ltd.
No. 278, Xinhu 1st Rd., Neihu Dist.,
Taipei City, Taiwan
Date & Place of Issue: 31/May/2022, Taipei
Signature:
Printed Name: Hunter Chen
Title: Director
Declaration of Conformity
We, Edimax Technology Co., Ltd., declare under our sole responsibility,
that the equipment described below complies with the requirements of the
United Kingdom Radio Equipment directives.
Equipment: Access Point
Model No.: EW-7889WAX, EW-7899WTX
The following European standards for essential requirements have been
followed:
Radio Equipment Regulations 2017 (S.I. 2017/1206)
Spectrum : EN 300 328 V2.2.2 (2019-07)
EN 301 893 V2.1.1 (2017-05)
Draft EN 303 687 V1.0.1 (2022-09)
EMC : EN 301 489-1 V2.2.3 (2019-11)
EN 301 489-17 V3.2.4 (2020-09)
EMF : EN IEC 62311: 2020
EN 50665: 2017
Safety (LVD) : IEC 62368-1:2014 (2nd Edition) and/or EN 62368-1:2014+A11:2017
Edimax Technology Europe B.V. Fijenhof 2,
5652 AE Eindhoven,
The Netherlands| a company of:
Edimax Technology Co., Ltd.
No. 278, Xinhua 1st Rd., Neethu Dist.,
Taipei City, Taiwan
---|---
Date & Place of Issue: 31/May/2022, Eindhoven
Signature:
Printed Name: David Huang
Title:
Director| Date & Place of Issue: 31/May/2022, Taipei
Signature:
Printed Name: Hunter Chen
Title: Director
---|---
Edimax Technology Co., Ltd.
No. 278, Xinhua 1st Rd., Neethu Dist., Taipei City, Taiwan
Email: support@edimax.com.tw
Edimax Technology Europe B.V.
Fijenhof 2, 5652 AE Eindhoven, The Netherlands
Email: support@edimax.nl
Edimax Computer Company
530 Technology Drive Suite 100, Irvine, CA 92618, USA
Email: support@edimax.us
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>