MPJA PZEM-022 AC 80-260V 100A Digital Meter Instruction Manual

June 8, 2024
MPJA

MPJA PZEM-022 AC 80-260V 100A Digital Meter

37214 ME
PZEM-022 AC 80-260V 100A Digital Meter with Split CT
NOTE: Do NOT Install CT on an Energized Circuit.

Always Be Sure CT Leads Are Connected To Meter

This product is an all in one instrument that can display Voltage, Current, Watts, Frequency, Power Factor and Wattage in WH. It can also record power consumption over a designated time period and sound internal alarm when it detects overload on the circuit.

Features

  • Electrical parameter measurement function (voltage, current, active power, energy, frequency, power factor)
  • Overload alarm function (over power alarm threshold, backlight and power flashing to alarm)
  • Power alarm threshold preset function (can set power alarm threshold)
  • The energy can be reset using the button
  • Store data when power off
  • Large-screen LCD
  • Backlight function
  • Button Control Function

Backlight control
Short press of the button to turn the backlight on or off. The backlight has memory function, it can store the on or off state when power off.

Reset energy

  • Step1: Long press the key for 5 seconds until the energy value flash, then release the key.
  • Step2: Short press the key again, then the energy value is cleared and exit the reset flashing state.
  • Step3: If there is no operation on the key within 5 seconds, it means the energy value is not cleared and will exit the reset state.

Set power alarm threshold

  • Step1: Long press the key until the LCD screen display “SET CLr”, then release the key to enter the setting state
  • Step2: Power window display the current power alarm value and the last digit begin to flash, then you can short press to plus 1, when there is no operating over 3 seconds, it will switch the digit position automatically, the setting method is as same as the above.
  • Step3: After finish the setting, long press the key over 5 seconds will store automatically and exit, the range of active power threshold is 0.0~2.5kW. it can display six parameters at the same time.

Specifications

  1. Working voltage: 80 ~ 260VAC
  2. Test voltage: 80 ~ 260VAC
  3. Rated power: 100A/22000W
  4. Operating frequency: 45-65Hz
  5. Measurement accuracy: 1.0 grade

Display format

  1. Power
    Test range: 0.2~22000W
    Starting measure power: 0.2W
    <10W display format: 1.00~9.99W
    <100W display format: 10.0~99.9W
    <1000W display format: 100~999W
    <10000W display format: 1.00~9.90kW
    10000W display format: 10.0~22.0kW

  2. Energy
    Test range: 0~999kWh

    • <1kWh display format: 0~999Wh
    • <10kWh display format: 1.00~9.99kWh
    • 10kWh display format: 10~999kWh
  3. Voltage
    Test range: 80~260V
    Display format: 80~260V

  4. Current
    Test range: 0~100A
    Starting measure current: 0.001A

    • <10A display format:0.000~9.000A
    • 10A display format:10.00~99.99A
  5. Frequency
    Test range: 45~65Hz
    Display format: 45~65Hz

  6. Power factor
    Test range: 0~1PF
    Display format: 0.00~1.00PF

Precautions

  1. This module is suitable for indoor, please do not use outdoor.
  2. Applied load should not exceed the rated power.
  3. Do NOT Miswire order can’t be wrong.

Information including Drawings, Schematics, Links and Code (Software) Supplied or Referenced in this Document is supplied by MPJA inc. as a service to our customers and accuracy or usefulness is not guaranteed nor is it an Endorsement of any particular part, supplier or manufacturer. Use of information and suitability for any application is at users own discretion and user assumes all risk.
All rights are retained by the respective Owners/Author(s) Information is Subject to Change Without Notice
Marlin P. Jones & Assoc., Inc
P.O. Box 530400 Lake Park, Fl 33403
800-652-6733 FAX 561-844-8764
WWW.MPJA.COM

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals