MANUAL DE INSTRUCCIONES DH 1240
Read this manual carefully before running this appliance and save it for reference in order to obtain the best results and ensure safe use.
DH 650 Dehumidifier
warning| This unit uses a flammable refrigerant.
If the refrigerant leaks and comes into contact with the fire or the heating
part, harmful gases will be created and there is a risk of fire.
---|---
| Read the INSTRUCTION MANUAL before using the appliance.
****| Information available in the INSTRUCTION MANUAL.
| Service personnel should read the INSTRUCTION MANUAL carefully before
proceeding.
CAUTIONS
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must never play with the appliance. Cleaning and user maintenance must never be carried out by children without supervision.
- Children should be supervised to ensure that they do not play with the appliance.
- Keep the appliance and the cable cord out of the reach of children less than 8 years old.
- WARNING: In order to ensure your children‘s safety, please keep all packaging (plastic bags, boxes, polystyrene etc.) out of their reach.
- If the supply cord is damaged it must be repaired by the Authorized Service Agent in order to avoid hazards.
- Never pull on the cord when unplugging.
- Do not use the unit with a damaged cord or plug, or if it is not working properly.
- Do not handle the appliance with wet hands.
- Never immerse the appliance in water or any other liquid.
- Make sure the appliance has been unplugged before cleaning.
- This appliance must be installed following the national regulations for electrical installations.
- This appliance is for household use only.
- In case that you need a copy of the instruction manual, you can find it in www.orbegozo.com
- WARNING: In case of misuse, there is a risk of possible injury.
- This appliance is designed to be used by skilled or trained users in shops, in light industry and on farms, or for commercial use by non- professionals.
- The unit is designed for use only with R-290 gas (propane) as the designated refrigerant.
- The refrigerant circuit is sealed. Only a qualified technician should attempt to open it!
- R-290 (propane) is flammable and heavier than air. It accumulates first in low areas, but fans can circulate it.
- If propane gas is present or even suspected, do not allow untrained personnel to try to find the cause.
- The propane gas used in the unit is odorless. The lack of odor does not indicate a lack of gas leakage.
- If a leak is detected, immediately evacuate everyone from the store, ventilate the room, and contact the local fire department to report a propane leak. Do not allow anyone to return to the room until the qualified service technician has arrived and advises you that it is safe to return to the store.
- Open flames, cigarettes or other possible sources of ignition should not be used in or near the units.
- Components are designed for propane and do not induce or produce sparks. Component parts should only be replaced with identical repair parts.
- Do not use an extension cord or adapter plug.
- Do not leave the unit running unattended. Do not tilt or turn the unit.
- Do not stand on or sit on the unit.
- Do not put your fingers or other objects in the air outlet.
- Do not clean the appliance with any chemical product.
- Make sure the unit is away from fire, flammable or explosive objects.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance should be stored in a room without sources of continuous operation (for example: open flames, a working gas appliance, or a working electric heater).
- The appliance must be stored in such a way as to avoid mechanical damage.
- Do not remove from mold or burn, even after use.
- Be aware that refrigerants may be odorless.
- Pipes must be protected against physical damage and must not be installed in a space without ventilation, if that space is less than 4m².
- Keep necessary ventilation openings free from obstructions.
- Compliance with national gas regulations must be observed.
- Keep necessary ventilation openings free from obstructions.
- Inspect the device after unpacking it for damage or scratches.
- Use this unit in an ambient temperature of 5 ° C to 38 ° C.
- Do not use it outdoors. This dehumidifier is designed for indoor residential applications only.
- Do not operate near walls, curtains or other objects that may block entry and exit.
- Keep the air inlet and outlet free of obstacles.
- If it is tilted more than 45 °, allow the unit to stand upright for at least 24 hours before turning it on.
- Keep doors and windows closed for better energy savings.
- Do not operate or store the unit in direct sunlight or in the rain.
- It is normal for the air outlet to feel warm to the touch after continuous operation on hot days.
- Empty the water tank before moving the device.
- Make sure the water tank is installed correctly; otherwise, the unit will not work properly.
- The dehumidifier turns on in the mode selected when the unit was last used.
- The dehumidifier starts dehumidifying if the humidity in the room is 3% higher than the selected humidity.
- There is a 3 minute compressor protection delay. Wait 3 minutes for the dehumidifier to resume dehumidification.
Anyone involved in the repair or interruption of a refrigeration circuit must
hold a current valid certificate from an accredited assessment authority
authorizing their competence to handle refrigerants safely.
Service should only be performed as recommended by the equipment manufacturer.
Maintenance and repairs that require the assistance of other trained personnel
should be carried out under the supervision of a person competent in the use
of flammable refrigerants.
FAILURE TO COMPLY WITH THESE WARNINGS COULD RESULT IN EXPLOSION, DEATH,
INJURY, AND PROPERTY DAMAGE
GENERAL VIEW
LOCATION
- Place the unit on a firm, level surface in an area with at least 30 cm of free space around it to allow adequate air circulation.
- Never install the unit where it may be exposed to:
– Heat sources such as radiators, heating registers, stoves or other products that generate heat.
– Oil or water splashes
– Direct sunlight
– Mechanical vibration or shock
– Excessive dust
– Poor ventilation, for example a closet or cupboard
– Uneven surface
WARNING
Install the unit in rooms larger than 4 m².
Do not install the unit in a place where flammable gas may leak.
NOTE
Manufacturing can provide another suitable example or can provide additional
information on the odor of the refrigerant.
FUNCTIONING
- CONTROL PANEL
- CONFIGURATION
Power button (POWER)
After connecting the appliance to the power, all the indicators and the display will turn on for 1 second and then turn off. There will be a beep, the power indicator will light, and the machine will be in standby mode.
By pressing this button the machine will start to work. The initial humidity of the machine is 60% RH, default auto mode and high fan operation.
Press this key again, the machine will stop working and the fan will turn off.
MODE button
Press the button to switch from one mode to another. The light corresponding to each one will turn on.
Description of modes
• Automatic mode:
When the room humidity is higher than the selected humidity +3%, the fan and compressor will start to work after 3 minutes. When the room humidity is lower than the selected humidity minus 3%, the compressor will stop working after 30 seconds.
Both humidity and fan speed can be selected in AUTO mode.
• Continuous mode:
The device works continuously, regardless of the humidity of the environment. The fan runs at high speed.
In CONTINUOUS mode, neither fan speed nor humidity can be selected.
• Night mode:
Touch the Mode button, the indicator with a moon lights up and the night function starts. After 10 seconds, all indicators on the control panel gradually darken and the air speed automatically changes from high to low. Touch any button to activate the control panel. Touch the mode button again to exit night mode.
In this mode, error codes are not displayed and the air speed cannot be adjusted. The humidity is adjustable.
HUMIDITY SELECT button
In auto mode or night mode, you can use this button to adjust the set humidity: each time you press, the set humidity is increased by 5%. It can be adjusted in a range of 30% to 80%.
Press and hold this button to check the current room temperature.
TIMER button
Press the TIMER button to set the timing function from 0-24 hours. The interval is 1 hour, increase or decrease the time displayed on the screen. When setting the time, the indicator will light up. Set “00” to cancel the function. After setting and completing the timer, the timer LED lights up for the period of time.
Once the time is up, the timer LED turns off automatically.
When the device is on, activate the timer to pay for it automatically.
When the device is off, activate the timer to turn it on automatically.
SPEED button
The air speed can only be adjusted in automatic mode. Press this key to change the air speed between high and low.
Lock button (LOCK)
Press and hold this key to open the child lock function. The lock indicator light will come on. All keys will be locked and cannot be used. Press this button again, the indicator light will turn off.![Orbegozo DH 650 Dehumidifier
-
CONTROL PANEL 1](https://manuals.plus/wp-content/uploads/2023/09/Orbegozo- DH-650-Dehumidifier-CONTROL-PANEL-1.png)
- LED INDICATOR
The color of the front led will change according to the humidity of the environment:
• Ambient humidity < 45%. Blue light
• Ambient humidity ≤ 65%. Green light
• Ambient humidity > 65%. Red light
- LED INDICATOR
SEWER SYSTEM
A. MANUAL DRAIN
The unit’s built-in water tank will fill up and the unit will stop working.
You will need to empty it and insert it correctly.
- When the tank is full, the appliance will emit an intermittent beep, the TANK FULL indicator will light up and the front LED will light up red.
- Turn off the dehumidifier (press the POWER button)
- Pull and slide the bin away from the unit and empty it.
- Clean the inside and outside of the tank
- Place the reservoir inside the device
- Press the POWER button to make the device work again
- If the TANK FULL light does not go off, check that the tank is correctly seated.
WARNING
- Do not get rid of the magnets and plastic rivets in the tank, otherwise the dehumidifier will not turn on or stop working automatically when the water tank is full and will overflow.
- Be sure to clean the condensed water in the tank and put it back in the original position.
- If the tank is dirty, clean it with clean water. Do not use detergents, aluminum scourers, dust cleaners, diesel, benzene, or solvents. Doing so may damage the tank and cause leaks.
- Put the water tank back to its original position. Otherwise, the indicator light will always be red, and the machine will not be able to work again.
B. CONTINUOUS DRAINING
- Connect the included PVC pipe to the drain outlet at the top of the tank.
- Connect the other end of the tube to a bathroom, house drain, or a defined drainage area.
WARNING
- Do not block the drain pipe, condensed water may flow into the tank.
- Do not bend the drain tube.
- The height of the tube should be less than the outlet.
- The tube must be firmly connected to the outlet.
- The reservoir must always be in place.
MAINTENANCE
NOTE: Before cleaning and maintaining the device, be sure to turn it off
and unplug it to avoid electric shock.
AIR FILTER CLEANING (every two weeks):
Clean the air filter every two weeks. Restricted airflow reduces the
efficiency of the system and, if blocked, can damage the unit. Proceed as
follows:
- Turn off the device and remove the air filter
- Rinse under running water or vacuum to remove dust.
- Once completely dry, reassemble the air filter
TROUBLESHOOTING
SYMPTOM | INSPECTION | SOLUTION |
---|---|---|
The unit does not work | ✓Check the power connection securely. | ➢ Insert the |
power cord securely into the wall socket.
✓Check if the TANK FULL indicator is on.| ➢ Empty the tank and reinstall it
correctly.
✓Check the room temperature.| ➢ The operating temperature range is 5-35°C.
Malfunction| ✓Is the air filter clogged?| ➢ Clean the air filter as indicated
✓Is the air inlet or outlet grille obstructed?| ➢ Remove obstruction from
vents
No air enters| ✓Is the filter clogged?| ➢ Wash the filter
Loud noise when running| ✓Is the machine placed on a platform?| ➢ Place the
machine on the ground
✓Is the filter clogged?| ➢ Wash the filter
Error code| E2| ✓- v Humidity sensor damp or faulty.| Clean or replace the
humidity sensor.
LO| ✓Displayed when the relative humidity is less than
20%RH.| ➢ The dehumidifier turns off
HI| ✓Displayed when the relative humidity is higher than 90%RH.
CL| ✓Displayed when the ambient temperature is below 5°C.
CH| ✓Displayed when the ambient temperature is higher than 38°C
DISPOSAL OF OLD ELECTRICAL APPLIANCES
The European directive 2012/19/EU on Waste Electrical and Electronic Equipment
(WEEE), requires that old household electrical appliances must not be disposed
of in the normal unsorted municipal waste stream. Old appliances must be
collected separately in order to optimize the recovery and recycling of the
materials they contain, and reduce the impact on human health and the
environment. The crossed out “wheeled bin” symbol on the product reminds you
of your obligation, that when you dispose of the appliance, it must be
separately collected. Consumers should contact their local authority or
retailer for information concerning the correct disposal of their old
appliance.
DECLARATION OF CONFORMITY:
This device complies with the requirements of the Low Voltage Directive
2014/35/EU and the requirements of the EMC directive 2014/30/EU.
GUARANTEE
This appliance is covered and is entitled to the legal guarantee in accordance
with the legislation in force from the date of purchase. Keep the purchase
receipt to be able to claim your right to the guarantee. To find the closest
service to your location, contact through the following web link:
https://orbegozo.com/asistencia-tecnica/
For any type of query, doubt or incident, you can contact us through our email
shown on the main page of this manual or through our technical assistance
service at https://orbegozo.com/contacto/
Orbegozo is not responsible for components and accessories that are subject to
wear and tear due to use, as well as perishable compounds or those that have
deteriorated due to improper use. Nor will it be held responsible if the owner
has technically modified the device. (Check the legal conditions on our
website).
Sonifer, S.A.
Avenida de Santiago, 86
30007 Murcia
España
E-mail: sonifer@sonifer.es /
www.orbegozo.com