BERTAZZONI MAS486GGASXV 48 Inch All Gas Range 6 Burner And Griddle Installation Guide

June 13, 2024
Bertazzoni

BERTAZZONI-LOGO

BERTAZZONI MAS486GGASXV 48 Inch All Gas Range 6 Burner And Griddle

BERTAZZONI-MAS486GGASXV-48-Inch-All-Gas-Range-6-Burner-And-Griddle-
PRODUCT

Product Information

  • Side View: Provides a view of the product from the side.
  • Leg Details: Contains information about the legs of the product.
  • Front View: Provides a front-facing view of the product.
  • Worktop Details: Contains detailed information about the worktop of the product.
  • Rear View: Provides a view of the product from the rear.

Product Usage Instructions

To ensure proper installation and compliance with local code requirements, please follow the instructions below:

Electrical Connection A properly-grounded horizontally mounted electrical receptacle should be installed:

  • No higher than 3 inches (7.6 cm) above the floor.
  • No less than 2 inches (5 cm) from the left side (facing the product).
  • No more than 8 inches (20.3 cm) from the left side (facing the product).

Make sure to check all local code requirements for electrical connections.

Gas Connection To ensure safe usage, follow these steps for gas connection:

  1. Install an agency-approved, properly sized manual shut-off valve.

  2. Place the shut-off valve at a maximum height of 3 inches from the floor.

  3. Ensure a minimum height of 2 inches and a maximum height of 8
    inches from the right side (facing the product).

  4. Use an approved shut-off valve and regulator gas connection.

  5. Use properly sized flex or rigid pipe for gas connection.

It is essential to check all local code requirements for gas connections.

NOTE:

  • a. Electrical Connection
  • b. Gas Connection

Dimension

INSTALLATION

  • A properly-grounded horizontally mounted electrical receptacle should be installed no higher than 3” (7.6 cm) above the floor, no less than 2” (5 cm) and no more than 8” (20,3 cm) from the left side (facing product). Check all local code requirements.
  • Install agency approved, properly sized manual shut-off valve at max. height of 3” from floor, 2” min. height/ 8” max. height from the right side (facing product). Use approved shut-off valve & regulator gas connection, properly sized flex or rigid pipe. Check all local code requirements.

NOTE

  • a. Electrical Connection
    • b. Gas Connection