SCANGRIP SUNMATCH 4 Work Light Rechargeable LED Light Owner’s Manual

June 13, 2024
SCANGRIP

SCANGRIP SUNMATCH 4 Work Light Rechargeable LED Light

Product Information

  • Product Name: SUNMATCH 4
  • Model Number: 03.5657
  • Features: CCT SCAN function, Stepless dimmer, Ultra high CRI+ COB LED, Spot: High power LED
  • Specifications:
    • Spot: 50-500 lm, Spot: 200 lm
    • Spot Lux at 0.5m: 700-1400 lux, Spot Lux at 0.5m: 5000 lux
    • Color Temperature Range: 2500K-6500K, Spot: 4000K
    • Color Rendering Index (CRI): Spot: 95 CRI, CRI 96+
    • Battery: 3.7V / 2600mAh Li-ion
    • Battery Life: Spot: 2-10h, Spot: 3h, Main Light: 4h
    • Impact Protection Rating: IK07
    • Water Resistance Rating: IP65
    • Dimensions: 188x58x26mm
    • Weight: 267g
    • Range: 1m
    • Included Accessories: USB cable, Charging input 5V DC 1A

Product Usage Instructions

WARNING:

  • Always respect applicable legislation for working with electrical equipment to reduce the risk of accidents.
  • Avoid looking directly into the beam of light, as this will result in dazzling.
  • Do not use the lamp near a naked flame.
  • The light source of this luminaire is not replaceable; when the light source reaches its end of life, the whole luminaire shall be replaced.

Usage:

  • Press the on/off button to turn the lamp on in the sequence: Main > Spot > Off.
  • Press and hold the on/off button while the main light is on to start dimming. Release, press, and hold again to increase.
  • At the lowest and highest levels, the light will flash until the button is released.
  • When the lamp is turned off, it will remember the setting of the main light.
  • When the light is on, press the CCT SCAN button to change the color temperature manually.
  • To activate the CCT SCAN mode, press and hold the CCT SCAN button for 2 seconds.
  • While in CCT SCAN mode, press the CCT SCAN button to pause the CCT SCAN mode.
  • To deactivate CCT SCAN mode, press and hold the CCT SCAN button for 2 seconds.
  • The CCT indicator corresponds to the following color temperature ranges in CCT SCAN mode: 25 (2500-3300K), 35 (3301-4100K), 45 (4101-4900K), 55 (4901-5700K), 65 (5701-6500K).

Charging / Battery:

  • During charging, the 4 LED bars will indicate the level of charge in red color. When fully charged, all 4 LED bars will light up with green color.
  • Battery capacity indicator: when the lamp is OFF, press and hold the on/off button for 2 seconds (Capacity indicator function is disabled when the lamp is on).
  • Use a 5V, 1A USB charger to charge the lamp.
  • Always replace the battery with a new one of the same type and grade.
  • Do not leave the battery discharged, as it could be over-discharged and may not be able to be recharged.
  • Dispose of the battery and discarded electrical products safely using recycling facilities. Please consult your local authority or retailer for advice on recycling.

BOX CONTENT

PRODUCT FEATURES

SCANGRIP-SUNMATCH-4-Work-Light-Rechargeable-LED-Light-
fig-2

WARNING

  • Always respect applicable legislation for working with electrical equipment to reduce the risk of accidents.
  • Avoid looking directly into the beam of light, as this will result in dazzling.
  • Do not use the lamp near a naked flame.
  • The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

USE

  • Press the on/off button to turn the lamp on in the sequence: Main > Spot > Off.
  • Press and hold the on/off button while the main light is on to start dimming. Release, press, and hold again to increase.
  • At the lowest and highest levels, the light will flash until the button is released.
  • When the lamp is turned off the lamp will remember the setting of the main light.
  • When the light is on, press the CCT SCAN button to change the color temperature manually.
  • When the light is on, press and hold the CCT SCAN button for 2 seconds to activate the CCT SCAN mode.
  • When in CCT SCAN mode, press the CCT SCAN button to pause the CCT SCAN mode.
  • When in CCT SCAN mode, press and hold the CCT SCAN button for 2 seconds to deactivate CCT SCAN mode. When in CCT Scan mode, the CCT indicator corresponds to the following color temperature ranges: 25: 2500-3300K, 35: 3301-4100K, 45: 4101-4900K, 55: 4901-5700K, 65: 5701-6500K.
  • To save battery and avoid the risk of overheating an intelligent built-in system turn the lamp to low mode (250 lumen) after 3 minutes of use at high mode (500 lumen).

CHARGING / BATTERY

  • During charging, the 4 led bars will indicate the level of charge in red color. When fully charged, all 4 led bars will light up with green color.
  • Battery capacity indicator: when the lamp is OFF, press and hold on/off button for 2 sec. (Capacity indicator function is disabled when the lamp is on).
  • Use 5V, 1A USB charger.
  • Always replace the battery with a new one of the same type and grade.
  • Don’t leave battery discharged. Otherwise, it could be over-discharged and may NOT be able to be recharged.

DISPOSAL

  • Discarded electrical products must not be disposed of together with household waste.
  • Please use recycling facilities. Ask your local authority or retailer for advice on recycling.
    • The battery must be removed from the device before it is broken up.
    • The device must be disconnected from the mains when the battery is removed.
    • Please dispose of the battery safely