APC BX Series 500VA Back UPS Tower User Manual
- June 13, 2024
- APC
Table of Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Product Handling Guidelines
- Safety and General Information
- Operational Features
- Battery Replacement
- Features
- Specifications
- Status Indicators
- Troubleshooting
- Detected Problem and Possible Cause The Back-UPS will not turn on :
- Connected equipment loses power
- The ON/OFF button ashes green and constant beeps every 1/2 second.
- Service
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**APC BX Series 500VA Back UPS Tower User Manual
**
IMPORTANT SAFETY INSTRUCTIONS
Read the instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this document or on the equipment to warn of potential hazards or to call attention to information that claries or simplies a procedure.
The addition of this symbol to either a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
Product Handling Guidelines
-
< 18 kg
< 40 lb -
18-32 kg
40-70 lb -
32-55 kg
70-120 lb -
55 kg
120 lb
Safety and General Information
SAVE THESE INSTRUCTIONS –
This manual contains important instructions that should be followed during
installation and
maintenance of the UPS and batteries.
Inspect the package contents upon receipt. Notify the carrier and dealer if
there is any damages.
- This UPS is intended for indoor use only.
- Mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.
- UPS must be connected to an earthed mains socket outlet.
- Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions. In this case, batteries is not user-replaceable.
- When replacing battery the UPS must be OFF, and its AC inlet unplugged.
- CAUTION Do not dispose of batteries in a re. The batteries may explode.
- CAUTION Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
- Do not open or mutilate batteries. They contain an electrolyte that is toxic and harmful to the skin and eyes.
- Failed batteries can reach temperatures that exceed the burn thresholds for touchable surfaces.
CAUTION A battery can present a risk of electrical shock and high short circuit current.
The following precautions should be observed when working on batteries.
a. Remove watches, rings or other metal objects.
b. Use tools with insulated handles.
c. Wear rubber gloves and boots.
d. Do not lay tools or metal parts on top of batteries.
e. Disconnect the charging source prior to connecting or disconnecting
battery terminals.
f. Determine if battery is inadvertently grounded. If inadvertently
grounded, remove source from ground. Contact with any part of a grounded
battery can result in electrical shock. The likelihood of such shock can be
reduced if such grounds are removed during installation and maintenance.
Radio Frequency Warning
This is a category C2 UPS product. In a residential environment, this product
may cause radio interference, in which case the user may be required to take
additional measures.
Product Description
The APC by Schneider Electric Back-UPS offers power and surge protection for
wireless networks, computers, gaming consoles and other electronics in your
home or business. This UPS supply battery backup during outages and unstable
voltage fluctuations, as well as provide protection from damaging surges and
spikes. It’s equipped with data line surge protection which safeguards your
equipment andvaluable files from “back door” surges traveling along data line.
They are the choice helps to protect your sensitive electronics.
Place and Power On
-
Place the Back-UPS to avoid:
- Direct sunlight
- Excessive heat
- Excessive moisture
- Excessive dust/dirt
For operation, please place the unit on the floor.
-
Connect the battery by pulling the battery handle up, and then pushing it into the unit.
-
Connect equipment to the UPS. Avoid using extension cords.
-
Plug the Back-UPS power cord directly into a wall outlet, not into a surge protector or power strip.
-
Press the ON/OFF button to turn on the unit.
The green “Power On” indicator confirms that the Back-UPS is on and ready to
provide protection.
The Back-UPS should charge for at least 24 hours to ensure sufficient runtime.
The unit is being charged whenever it is connected to AC power, whether the
unit is turned ON or OFF.
Back-UPS BX Series 500VA, 750VA, 950VA, 1200VA, 1600VA, 2200VA
Operational Features
Automatic Voltage Regulation (AVR)
Automatic Voltage Regulation boosts/trims the AC voltage when it drops/exceeds levels. This allows the equipment plugged into the unit to operate during low/high voltage conditions, conserving the battery power in the event of a power cut. The Back-UPS will switch to battery power if the inputvoltage level becomes too low/high for the Automatic Voltage Regulation to compensate, or if the AC power is distorted.
Power Chute Personal Edition Software TM
To install Power Chute Personal Edition (PCPE) software, connect a USB cable
to the data port on the UPS and the other end to a computer with access to the
web. On the computer, go to
www.apc.com/tools/download. Select
“Software Upgrades – PowerChute Personal Edition” in the
“Filter by Software/Firmware” drop down menu. Select the appropriate operating
system. Follow directions to download the software.
Quick Mute
The Back-UPS is able to temporarily mute user correctable audible alarms such as On Battery. During such audible alarms, a short press of the POWER button will temporarily mute the audible alarm until the condition has been reset. A short double beep will confirm that Quick Mute has been activated. Pressing the POWER button for more than 2 seconds will turn off the UPS.Other critical events such as Battery replacement and Charger notification can not be temporarily muted. The unit in these cases must be turned off
Voltage Sensitivity Adjustment
Ensure the Back- UPS is off. Press and hold 10 seconds until d. the POWER
button for a beep is hearThe LED will flash and sensitivity LOW is set. If
press and hold the POWER button for 10 seconds again, the LED will be on and
sensitivity MEDIUM is set.
LED status| Sensitivity Setting| Input Voltage Range|
Recommended Use
---|---|---|---
Flash| LOW| 140 Vac to 300 Vac| Use this setting with equipment that is less
sensitivity to fluctuations in voltage or waveform distortions.
On| MEDIUM| 145 Vac to 295 Vac| Factory default setting. Use this setting
under normal conditions
LED Brightness Setting
The Back -UPS is able to control LED brightness. During On Line Mode, a
short press of the POWER button will dim the LED brightness and heard a beep.
Press one more time, the LED brightness will return again.
Self-Test
Battery Replacement
CAUTION
RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
- Replace the battery at least every 5 years or at the end of its service life, whichever is earlier.
- Replace the battery immediately when the UPS indicates battery replacement is necessary.
- Replace batteries with the same number and type of batteries as originally installed in the equipment.
- Replace the battery immediately when the UPS indicates a battery over-temperature condition or when there is evidence of electrolyte leakage. Power off the UPS, unplug
it from the AC input, and disconnect the batteries. Do not operate the UPS until the batteries have been replaced.
Failure to follow these instructions can result in minor or moderate injury and equipment damage.
The battery in the Back-UPS is not user-replaceable. Contact SEIT Technical
Support for a list of authorized service centers near you.
For the recycling battery information, please go to apc.com/recycle.
Features
A ON/OFF button with indicator
B Input power cord
E Circuit breaker
C Battery backup and surge protected outlets only for model with IEC
socket
C Battery backup and surge protected outlets only for model with IEC socket
F AC power inlet with AC fuse
G USB data port
H In/Out Ethernet surge-protected ports
E Circuit breaker
F AC power inlet with AC fuse
G USB data port
H In/Out Ethernet surge-protected ports
Model | BX750MI-GR BX950MI-GR | BX750MI-AZ | BX950MI-AZ | BX750MI-MS | BX950MI-MS |
---|---|---|---|---|---|
Output Type and Quantity | x 4 | x 3 | x 4 | x2 x 1 | x 2 x 2 |
Model | BX500MI | BX750MI | BX950MI | BX750MI-FR | BX950MI-FR |
Output Type and Quantity | x 3 | x 4 | x 6 | x 3 | x 4 |
Model| BX1200MI BX1600MI BX2200MI| BX1200MI-GR BX1600MI-GR BX2200MI-GR|
BX1200MI-FR BX1600MI-FR BX2200MI-FR| BX1600MI-MS BX2200MI-MS| BX1200MI-AR/AZ
BX1600MI-AR/AZ BX2200MI-AR
---|---|---|---|---|---
Output Type and Quantity| x 6| x 4| x 4| x 4| x 4
Model| BX1200MI-MS|
Output Type and QuantityG H| x 4 x 1
- BX1200MI
- BX1600MI
- BX2200MI
- BX1600MI BX2200MI
IEC jumper Cable for PC connection(1.2m)
*only for the model with IEC outlet
USB communication cable (1.2m)
Specifications
Model| BX500MI| BX750MI| BX950MI| BX1200MI|
BX1600MI| BX2200MI
---|---|---|---|---|---|---
Input| Voltage| 220-240 Vac
Frequency| 50 Hz or 60 Hz (auto-sensing)
Brownout Transfer| 140 Vac, typical
Over-voltage Transfer| 300 Vac, typical
Output| UPS Capacity (total)| 500VA/300W| 750VA/410W| 950VA/520W|
1200VA/650W| 1600VA/900W| 2200VA/1200W
Voltage On Battery| 230 Vac ±10%
Frequency – On Battery| 50 Hz / 60 Hz ± 0.5Hz
Transfer Time| 6ms typical, 10ms max.
Protection| AC Input Circuit Breaker| 5A/ 250Vac| 5A/ 250Vac| 7A/
250Vac| 10A/250Vac| 12A/250Vac| 15A/250Vac
AC Input Fuse| | T 5A L 250Vac| T 8A L 250Vac| T 10A L 250Vac| T 12A L 250Vac|
T 15A L 250Vac
Battery| Type (maintenance-free)| 12V, 7AH x 1lead acid| 12V, 9AH x
1lead acid| 12V, 9AH x 1lead acid| 12V, 9AH x 1lead acid| 12V, 7AH x 2lead
acid| 12V, 9AH x 2lead acid
Average Life| The battery typically lasts for three to ve years.
Environmental factors impact battery backup life.Elevated temperatures, high
humidity, poor quality mains power, and frequent, short duration discharges
will shorten battery life.The battery in the Back- UPS Series is not user-
replaceable. Contact SEIT Technical Support for a list of authorized service
centers near you.
Typical Recharge Time| 8 hours to 90% capacity
Physical| Net Weight| 4.2 kg| 5.4 kg| 6.1 kg| 7.6 kg| 10.3 kg| 12.3 kg
Dimensions(Hx Wx D) cm| 13.8 x9.8x 31| 16 x12 x 35.5| 19 x14 x 39
Shipping Weight| 4.5 kg| 5.9 kg| 6.6 kg| 8.6 kg| 11.3 kg| 13.3 kg
Shipping Dimensions(H x Wx D) cm| 22.2 x 14.2 x 34.6| 25 x 19.7 x 43| 29.7 x
23.5 x 49.5
Tempera- ture| Operating| 0 °C to 40 °C
International Protection Code| IP20
The length of input power cord is 1.2m. For best operation, do not use output
cable longer than 2m.
** The length of USB communication cable is 1.2m. For best operation, do not
use communication cable longer than 3m.
Status Indicators
LED | Audible Alarm | Condition |
---|---|---|
On | Off | On-line – The Back- UPS is supplying AC power to the |
connected equipment
Constant Tone| On Line Overload – The power being used by the connected
equipment has exceeded the capacity of the unit.Disconnect some equipment.
Constant beeping (every 1/2 second)| Over-temperature Detected – The unit
is overheating and will operate in AVR mode for 1 minute. The Back-UPS will
shut down if the temperature is not lowered. Disconnect some of the connected
equipment.
On (Off during 4 beeps)| 4 beeps repeatedevery 30 seconds| On-
Battery – The Back- UPS is supplying battery power.
Flashing| Constant beeping (every 1/2 second)| Low Battery – The
Back- UPS is supplying battery power and the battery is near a total
discharge state.
Constant tone| Replace Battery Detected – The battery needs to be
charged, or is at end of life. Note: – If the battery is disconnected,
unplug the Back-UPS from AC source and then turn it off. Refer to the section
“ Place and Power On” on page 3.- If battery needs replacement, refer to the
section “Battery Replacement” on page 2 for details.
Off| Short beep every 4 seconds| Low Battery Shutdown – During On
Battery operation the battery power was almost completely exhausted, and the
Back-UPS is waiting for AC power to return to normal.
Constant Tone| On Line Overload Fault – The connected equipment requires
more power than provided by the Back-UPS.Unplug devices one at a time to
remove overload. If the detected problem is not corrected, contact SEIT
Technical Support
Charger Detected Fault – Back- UPS has an internal problem detected, and
is no longer powering the load. Contact SEIT Technical Support
Long beep every 4 seconds| Over-temperature Detected Fault – The Back-
UPS has overheated and has shut down. Unplug connected devices one at a time
or wait for a few hours for system to cool down.
Troubleshooting
Detected Problem and Possible Cause The Back-UPS will not turn on :
Solution
The Back- UPS has not been turned on. | Press the ON/OFF button. |
---|
The Back- UPS is not connected to AC power, there is no AC power available at
the wall outlet, or the AC power is experiencing a brownout or over voltage
condition.| Make sure the power cord is securely connected to the wall outlet,
and that there is AC power available at the wall outlet. Where applicable,
check that the wall outlet is switched on.
The battery is disconnected.| Refer to the “Place and Power On” on page 3.
Connected equipment loses power
A Back- UPS overload condition has occurred.| Remove all nonessential
equipment connected to the outlets. One at a time reconnect equipment to the
Back-UPS.Charge the battery for 24 hours to make sure it is fully charged. If
the overload condition still occurs, replace the battery.
---|---
The Back- UPS battery is completely discharged.| Connect the Back-UPS to AC
power and allow the battery to recharge for ten hours.
Connected equipment does not accept the step-approximated sine waveform from
the Back- UPS.| The output waveform is intended for computers and peripheral
devices. It is not intended for use with motor driven equipment.
The Back- UPS may require service.| Contact Schneider Electric Technical
Support for more in depth troubleshooting
The ON/OFF button is green and ashing every 30 seconds. 4 beeps repeated every 30 seconds.
The Back-UPS is operating on battery power.| The Back- UPS is operating
normally on battery power. At this point the user should save all open les,
and shutdown the computer. When AC power is restored the battery will
recharge.
---|---
The ON/OFF button ashes green and constant beeps every 1/2 second.
The Back-UPS battery has approximately empty and will shutdown| The Back-UPS
battery is near a total dischargestate. At this point the user should save all
open les, and shutdown the computer. When AC power is restored the battery
will recharge.
---|---
The Back – UPS has an inadequate battery runtime
The battery is not fully charged. The battery is near the end of useful life
and should be replaced.| Leave the Back- UPS connected to AC power for ten
hours while the battery charges to full capacity. As a battery ages, the
runtime capability decreases.
---|---
The UPS and outlets are off but the UPS keeps beeping once every 4 seconds. The audible alarm will mute after 32 seconds.
The UPS have shut down due to low battery, but control power exists.| The UPS
will return to normal operation once the AC input voltage has returned to a
normal range.
---|---
Service
f the unit requires service, do not return it to the dealer. Follow these steps:
-
Review the Troubleshooting section of the manual to eliminate common problems.
-
If the problem persists, contact Schneider Electric IT (SEIT) Customer Support through the APC by Schneider Electric website, www.apc.com.
a. Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit.
b.Call SEIT Customer Support and a technician will attempt to solve the problem over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#).
c. If the unit is under warranty, the repairs are free.
d. Service procedures and returns may vary internationally. Refer to the APC by Schneider Electric website for country specific instructions. -
Pack the unit in the original packaging whenever possible to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty.
-
Always DISCONNECT THE UPS BATTERIES before shipping. The United States Department of Transportation (DOT), and the International Air Transport Association (IATA) regulations require that UPS batteries be disconnected before shipping. The internal batteries may remain in the UPS.
-
Write the RMA# provided by Customer Support on the outside of the package.
-
Return the unit by insured, pre-paid carrier to the address provided by Customer Support.
Warranty
Register your product on-line.http://warranty.apc.com
The standard warranty is two (2) years from the date of purchase. SEIT
standard procedure is to replace the original unit with a factory
reconditioned unit. Customers who must have the original unit back due to the
assignment of asset tags and set depreciation schedules must declare such a
need at first contact with an SEIT Technical Support representative. SEIT will
ship the replacement unit once the defective unit has been received by the
repair department, or cross-ship upon the receipt of a valid credit card
number. The customer pays for shipping the unit to SEIT. SEIT pays ground
freight transportation costs to ship the replacement unit to the customer.
APC by Schneider Electric IT Customer Support Worldwide
For country specific customer support, go to the APC by Schneider Electric
website, www.apc.com.
© 2021 APC by Schneider Electric. APC, the APC logo are owned by Schneider Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective owners.