HUMIDIFIER WARRANTY

For more information regarding the warranty policy, Please visit our website: www.allinexporters.com/warranty Thank you for purchasing Allin Exporters Lotus Shape Cool Mist Humidifier which has been appreciated across the globe for its compliance with international stringent quality standards.
THIS HUMIDIFIER COMES WITH 3 MONTHS LIMITED WARRANTY AGAINST MANUFACTURING DEFECTS UNDER NORMAL USE.
WARRANTY REQUIRES A DATED PROOF OF PURCHASE.
STEPS TO ACTIVATE WARRANTY

  1. Log on to: www.allinexporters.com/warranty
  2. Complete Warranty Registration Form given on the website.
  3. Save confirmation email received on your email ID for warranty related claims in future.

LIMITED WARRANTY

The warranty on Allin Exporters Lotus Shape Humidifier is limited to only manufacturing defects.
Warranty will be void in case of misuse, accidental damage, product abuse, defect due to negligence, iImproper repair or alteration with standard design or part by unauthorized persons, or defect arising from failure to follow operating instructions provided in this manual including using essential oils or any otheraromatic product directly into the tank and base.
This warranty Is effective only If the product is purchased through seller authorized by Allin
WARNING: Any kind of Essential Oil, Medication, or Aromatic Product is not permitted for use with this humidifier. Any sign of using aforesaid products will void the warranty claim. The body may react with Essential Oils (like Citrus oils) to diffuse harmful & reactive mist. If you’re looking to have humidification and aroma diffuser in one unit, try our range of 2-in-1 Ultrasonic Diffusers and Humidifiers that are made of BPA-free plastic and are safe to use Essential oils and other aromatic broducts and maintaining humidity in the interiors.
NOTE:

  • Kindly register your purchase within 5 days to activate warranty.
  • Warranty will be applicable only if activated online else no claim will be entertained.

ANY QUESTIONS?
Call: +91-93-1313-2789
| +91-120-242-2053
Whatsapp: +91-93-1313-2789
E-Mail: sales@allinexporters.com

IMPORTANT SAFETY INSTRUCTIONS

WARNING: Read these instructions before using the humidifier Do not use any kind of essential oil, aromatic product or anything other than water inside the water tank or over the surface to prevent malfunctioning of unit.
Always ensure to lift water tank with both the hands.
This humidifier is intended for indoor use only. Do not use this humidifier in open areas.
Always ensure to fill water in humidifier before connecting to mains.
Use only cool tap water to ensure clear mist generation. We recommend to use filtered or distilled water if tap water is of substandard quality. Do not use hard water.
Never operate the unit with wet hands or damaged cord and plug to avoid electric shocks while plugging and unplugging the device.
Never operate the unit with wet hands or damaged cord and plug to avoid electric shocks while plugging and unplugging the device.
Fnsure to tighten the water tank cap on its base and aim the humidifier outlet away from children, walls, furniture and electrical appliances.
Place the humidifier on a smooth and flat surface with cord away from heated surfaces and areas. It is recommended to unplug the humidifier when not in use or during cleaning procedures.
Leave the room partly open when using this device in an enclosed area to avoid condensation on walls or furniture due to increased humidity in the interiors.
Take necessary precautions while cleaning the interior of this humidifier in such away that water should not come in contact with fan vent or electrical controls to prevent device damage. Please refer to the MAINTENANCE in this manual for proper cleaning operations.
Do not lift or tilt the top of humidifier or try to fill or empty its tank during operation.
Do not try to use detergent or soap to clean the parts that come in contact with water as detergent?fllm can interfere with the electrical components of this humidifier.
THIS HUMIDIFIER IS INTENDED FOR INDOOR USE ONLY.

LIST OF MAIN PARTS

FIGURE 1| | Humidifier Base
1.Nebulizer
2.Fan Outlet
3.Control Dial
4 Water Level Sensor
---|---|---
FIGURE 2| | Bottom of Water Tank
5.Mist Outlet Channel
6.Water Tank Cap
FIGURE 3| | Mist Lid
7.Mist Output Slot
FIGURE 4| | Water Tank
8. Take Upper Tank Out to Fill Water. Unscrew the Base Cap.
FIGURE 5| | Water Filling
9. Use only RO or demineralized water for healthier arr.

TECHNICAL SPECIFICATIONS

Voltage AC100-240V
Capacity Approx. 2400 ml
Ultrasonic Frequency 2 MHz
Power About 23 -27W
Max Time Up to 12 hours
Humidifying Capacity Up to 250 sq. ft. I 23m2
Mist Output 200 -250mIdhour
Humidification Area 40 – 50 Sq. m.
Material PC and ABS Plastic
Color White & Pink

WATER SHORTAGE AUTOMATIC PROTECTION (RED LIGHT ON).

ASSEMBLY & USE

ALWAYS use fresh cool water when operating the humidifier.

  1. Turn water tank upside down and unscrew the cap of water tank to fill cool water.
    NEVER
    fill water up to brim.
    NEVER use hot water.
    EVER add any essential oils, medication, or aromatic product.
    EVER pour water through mist outlet.

  2. Precisely screw the cap back over the water tank and upright the water tank over the Humidifier Base. Make sure to fit both parts securely.

  3. Plug the power cord of humidifier into the wall socket and turn on the unit by rotating Control Dial.

  4. Check power indicator light in green that indicates enough water level and mist will automatically emit from the mist outlet.

  5. Rotate the Control Dial to adjust the output of mist intensity.

  6. Ifthe LED Indicator of the humidifier turns to red, it indicates that water tank is empty or at low level. It is a safety feature to prevent burnout of ultrasonic plate and damaging of Nebulizer unit. Turn off the humidifier and refill the water tank for efficient operation.

MAINTENANCE

ROUTINE CLEANING OF THIS HUMIDIFIER IS ESSENTIAL TO ENSURE THE BEST HUMIDIFICATION PERFORMANC
NOTE: Do not left water in the tank for prolonged period as it may result in mineral deposits and bacteria buildup that may decrease the output efficiency as well as void the warranty.
Bacterial growth Is possible if water remain in the tank for more than a day or two. Please keep the unitdry if you are not intended of using it for longer period.
DAILY MAINTENANCE

  1. Turn off the humidifier and unplug the power cord from wall outlet.
  2. Empty water tank & base dally and let the tank & base to air dry.
  3. Put the cap off and let the humidifier dry before next use.

WEEKLY MAINTENANCE

  1. Turn off the humidifier and unplug the power cord from wall outlet.

  2. Add water to tank up to half and 3-4 teaspoons of vinegar and shake the unit vigorously and let the unit rest for 30 minutes.

  3. Empty the tank fully and rinse the humidifier with plain water.

  4. hill the base with lukewarm water and add 2 teaspoon of white vinegar let the unit rest for 30 minutes. Empty the base fully and rinse the humidifier with plain water. Ensure to pour water away from the fan located at the bottom.
    TIP: Clean the nebulizer unit with a damp cotton swab or cloth after soaking in water.

  5. Allow tank & base to air dry and leave cap off the tank until the next use.

  6. NEVER IMMERSE HUMIDIFIER BASE IN WATER.

PRODUCT VIDEO TUTORIAL
www.youtube.com/watch?v=889870V8yy|
If you have any questions about the operation of your
Humidifier, please contact Allin Exporters customer care.
ALLIN EXPORTERS CUSTOMER CARE
Call: +91-93-1313-2789 | +91-120-242-2053
Whatsapp: +91-93-1313-2789
E-Mail: sales@allinexporters.com