GE APPLIANCES YR-HQ Duct-Free System Owner’s Manual
- June 13, 2024
- GE Appliances
Table of Contents
- GE APPLIANCES YR-HQ Duct-Free System
- Product Information: Duct-Free System
- Product Usage Instructions
- IMPORTANT SAFETY INFORMATION
- Remote Control Features and Settings
- Manual Operation (POWER Button) and Maintenance
- Troubleshooting Tips
- Limited Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GE APPLIANCES YR-HQ Duct-Free System
Product Information: Duct-Free System
The Duct-Free System is a cooling and heating system that provides comfort in any room without the need for ductwork. It is designed to efficiently cool or heat the air and maintain a comfortable indoor environment. The system comes with a remote control for easy operation and adjustment of settings.
Product Usage Instructions
IMPORTANT SAFETY INFORMATION:
- Read all instructions before using the system.
- Keep flammable materials away from the system.
- Dispose of old products with refrigerants properly.
- Keep batteries away from children.
Remote Control Features and Settings:
- POWER Button: Press to start or stop the unit.
- HEAT Button: In HEAT mode, warm air will blow out. The fan speed adjusts automatically based on room temperature.
- COOL Button: In COOL mode, cool air will blow out. The fan speed adjusts automatically based on room temperature.
- DRY Button: Use for dehumidification. The fan speed remains low in DRY mode.
- SPEED Button: Changes fan speed (LOW-MID-HI-AUTO). Hold for 10 seconds to enter FAN mode.
- TURBO Button: Speeds up the air flow to the highest speed in heating and cooling mode.
- QUIET Button: Lowers the fan speed to the lowest speed.
- SWING UP/DOWN Button: Adjusts the position of the horizontal airflow louvers.
Refer to the user manual for more information on system operation, maintenance, troubleshooting tips, and warranty details.
IMPORTANT SAFETY INFORMATION
WARNING For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
- Use this appliance only for its intended purpose as described in this Owner’s Manual.
- This heat pump must be properly installed in accordance with the Installation Instructions before it is used.
- Turn the unit OFF before cleaning the air filter
- GE Appliances, a Haier company does not support any servicing of the heat pump. We strongly recommend that you do not attempt to service the heat pump yourself.
- For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
- These R410A heat pump systems require contractors and technicians use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
Keep batteries away from children.
- This remote controller contains batteries. If a new or used battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours.
- Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children.
- If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
- The cells shall be disposed of properly, including keeping them away from children.
- Even used cells may cause injury.
WARNING
-
This product is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. -
Children should be supervised to ensure that they do not play with the product.
-
Any damage of electrical supply must be replaced by persons in order to avoid a hazard.
READ AND SAVE THESE INSTRUCTIONS
Remote Control Features and Settings
Remote Control
-
POWER Button
Press the POWER button on the remote controller to start or stop the unit. -
HEAT Button
In HEAT mode, warm air will blow out after a short period of time due to the cold-air prevention function. When FAN is set to AUTO mode, the heat pump automatically adjusts the fan speed according to room temperature. The will be displayed during HEAT mode. -
COOL Button
In COOL mode, the heat pump will blow cool air. When FAN is set to AUTO, the heat pump automatically adjusts the fan speed according to the room temperature. The will be displayed during COOL mode. -
DRY Button
DRY mode is used for dehumidification. In DRY mode, when room temperature becomes lower than setting temperature +2°F, the Heat Pump will run intermittently at LOW speed regardless of FAN setting. The crossed out water droplet will be displayed during DRY mode. -
SPEED Button
With each press of the SPEED button, the fan speed changes as follows: LOW- MID-HI-AUTO. The remote controller display will show the fan icon. Hold the SPEED button for 10 seconds to go into FAN mode. Press any other button to exit this function. -
TURBO Button
The TURBO function is used for speeding up the air
flow to highest speed in heating and cooling mode. The user interface will display the “TURBO” icon. Pressing the TURBO again or SPEED button will exit the Turbo function. -
QUIET Button
The QUIET function is used for lowing the fan speed to the lowest speed. The control will display the QUIET icon on the user interface. Pressing the QUIET button again or the FAN Speed button will exit the QUIET function. -
TEMP +/- Button
TEMP + : The setting temperature will increase 1°F
(0.5°C) when pressed. TEMP – : The setting temperature will decrease 1°F (0.5°C) when pressed. The range of operating temperature is 60°F-86°F (16°C-30°C). -
MOTION SENSOR
Press the MOTION SENSE button to activate Motion Sense mode. Eco will be displayed on the screen. If after 20 minutes no person is detected in the room, the unit will enter the Eco mode. In this mode the unit will decrease the temperature set point 1°F (0.5°C) every 10 minutes in heat mode until it reaches 68°F (20°C) or increase the temperature set point 1°F (0.5°C) every 10 minutes in cooling mode until it reaches 78°F (26°C). Accumulated increase or decrease will not exceed 4°F (2° C). If motion sensor detects motion in the room, it will exit the Eco mode and change the temperature or the original setpoint immediately. If the set temperature is below 68°F (20°C) while in heating mode or 78°F (26°C) while in cooling mode, this function will not be able to change temperature further. -
SWING UP/DOWN
Press the SWING UP/DOWN button to choose the position of the horizontal airflow louvers. Status display of air flow
NOTE:- It is advisable not to keep the vertical louver in the downward position for an extended period of time in COOL or DRY mode. This may cause condensate water to form on the louver.
- When turning the unit on, the remote control will automatically return the louver to the previous set swing position. When turning the unit off, the louver will rotate to the full open position prior to closing.
-
SWING SIDE/SIDE Button (select models) Press the LOUVER SIDE/SIDE button to choose the position of the vertical airflow louvers.
Status display of air flow
NOTE:
1. When the humidity is very high, the condensate water may occur on the air outlet if all vertical louvers are adjusted too far to the left or right.
2. When turning the unit on, the remote control will automatically return the louver to the previous set position.
-
DISPLAY
Turns on and off the indoor display. Press the DISPLAY button 10 times within 5 seconds to display the ambient temperature. The indoor unit will beep 2 times when the setting is successful. Press the DISPLAY button 10 times within 5 seconds again to display the set temperature. The indoor unit will beep 4 times when the setting is successful. The default display temperature is the set temperature. -
SLEEP
Press the SLEEP button, the heat pump will operate the sleep function, the display light will be turned off after 20 seconds. The control logics are as following running in different mode.
* **COOL or DRY modes**
One hour after SLEEP mode begins, the temperature setpoint will increase 1°F
(0.5°C). 2 hours after beginning sleep mode the setpoint will increase 1°F
(0.5°C). Seven hours after beginning sleep mode, the setpoint will decrease
1°F (0.5°C). At the eighth hour the unit will be back to the original
setpoint. This feature helps with achieving maximum efficiency and comfort
while you sleep. See the image below.
* **Heat Mode**
One hour after SLEEP mode starts, the setting temperature will decrease 2°F.
After 2 hours, the setting temperature will decrease additional 2°F. After 5
hours, the setting temperature will increase 1°F. After 8 hours, the unit will
run according to the initial setting temperature. This feature helps with
achieving maximum efficiency and comfort while you sleep.
* **AUTO mode**
The unit operates in corresponding sleep mode adapted to the automatically
selected operation mode.
NOTE:
* When the unit is set to sleep mode, the fan speed will be set to low speed and cannot be changed.
* When the TIMER function is set, the sleeping function cannot be set. If the sleeping function has been set and the user sets the TIMER function, the sleeping function will be canceled and the unit will be set to the timer function.
-
FOLLOW
Press the FOLLOW button, the air will follow the body no matter people stand or moving. See chart below. Model| Detect Area| Louver Up/ Down| Louver Left/ Right
---|---|---|---
FOLLOW| Detect person in single zone| Remote setting position| Swing in the direction of the person
Detect person in multi zones| Remote setting position| Swing automatically
Detect nobody| Keep the initial setting position| Keep the initial settings position -
SURROUND
Press the SURROUND button. The air will surround the body no matter whether people are standing or moving. See chart below. Model| Detect Area| Louver Up/ Down| Louver Left/ Right
---|---|---|---
SURROUND| Detect person in single zone| Remote setting position| Keep the initial setting position
Detect person in multi zones| “Health airflow (up) in cooling mode
Health airflow (down) in heating mode”| Swing automatically
Detect nobody| Keep the initial settings position| Keep the initial settings position -
AUTO
The heat pump will automatically select Cool, Heat, or Fan operation according to set temperature. When FAN is set to AUTO the heat pump automatically adjusts the fan speed according to room temperature. -
VACATION
10°C/50°F Heating sets the system to maintain
10°C/50°F. This is used to prevent freezing during long unoccupied periods of time. -
TIMER ON/OFF
To set the Timer using the TIMER ON button, press the CLOCK UP/DOWN. The time will be changed by 1 minute. Press the APPLY to confirm the setting. Press the TIME OFF button to cancel the timer function. -
CLOCK
To set the clock using the CLOCK button, press the CLOCK UP/DOWN. The time will change by 1 minute. Press the APPLY to confirm the setting. The clock will keep the original time if the APPLY button is not pressed in 10 seconds. -
APPLY
Save and Cancel the TIMER and CLOCK selection. -
F/C
Press F/C to switch the remote and unit display temperature between Fahrenheit and Celsius.
Manual Operation (POWER Button) and Maintenance
Manual Operation
- Use the POWER button only when the remote control is lost or damaged.
- Press the POWER button and the unit will beep once, indicating start of operation.
- The unit will run automatically in the following modes:
- While in Manual Operation, temperature and fan speed
Room Temperature| Designated Temperature| Timer Mode| Fan Speed| Operation
Mode
---|---|---|---|---
Above 73°F| 79°F| No| AUTO| COOL
Below 73°F| 73°F| No| AUTO| HEAT
cannot be changed, nor will it operate in timer or DRY mode.
Inserting the Batteries
- Remove the battery cover
- Insert 2 AAA batteries as illustrated noting battery polarity
- Reinstall the battery cover
NOTE:
- The distance from the remote control to the receiver should be less than 23 feet with no obstructions.
- If the remote control display is weak or the operating distance has diminished, the batteries may need to be replaced.
- Remote control malfunctions can sometimes be corrected by removing the batteries from the remote for a few minutes and then reinstalling them.
- Remove the batteries from the remote control if the unit will not be in use for an extended period of time. If any segments of the display remain active after battery removal, press the reset button.
Optimizing Performance
- Close doors and windows during operation
- Do not block the air inlet or outlet
- Wipe the cabinet using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping down the unit. Then wipe off the detergent completely.
Cleaning the Front Cover
-
Open the front cover by pulling it upward
-
Remove the Filter:
Gently push up on the filter’s center tab until it is released from the stopper, and remove the filter in a downward motion. -
Clean the filter
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely. -
Attach the filter
Attach the filter so that the “FRONT” label is facing outward. Make sure that the filter is securely attached behind the holding tabs. If the filter is not attached correctly the unit may not achieve maximum efficiency. -
Close the front cover.
Troubleshooting Tips
Before you call for service
For additional troubleshooting tips, see the full installation manual at
GEAppliances.com/ductless or
Haierappliances.com/ductless
Problem | Cause and Solution | |
---|---|---|
Normal Performance Inspection | The system does not restart immediately | When |
the unit is stopped, it will not restart again for 3 minutes to protect the
system.
When electricity is disconnected then reconnected, the protection circuit will
be active for 3 minutes to protect the heat pump.
Noise is heard| During unit operation or a sudden stop, a swishing or gurgling
noise may be heard. The first 2-3 minutes after the unit has started is when
the noise could be noticeable. This noise is generated by refrigerant flowing
in the system.
During unit operation, a cracking noise may be heard. This noise is sometimes
generated by the casing expanding or shrinking due to temperature changes.
If the airflow is creating a loud noise during unit operation, the air filter
may be too dirty.
Odors| The system circulates odors lingering in the airstream, such as the
smell of furniture, paint, and/or cigarettes.
Mist or steam is blowing out| During COOL or DRY mode, the indoor unit may
blow out mist or steam. This is due to the sudden cooling of the indoor air.
In DRY mode, fan speed cannot be changed| In DRY mode, when the room
temperature becomes lower than the set temperature by 2°F, the unit will run
intermittently at LOW speed regardless of FAN setting.
Items to look for| Nonresponsive unit| Is there a power failure? Is the
circuit breaker off?
Is the fuse blown?
Poor Cooling| Is the air filter dirty?
Is there anything blocking the inlet and/or outlet? Is the temperature set
correctly?
Are there any doors or windows open?
Is there any direct sunlight shining through the window during the cooling
operation?
Are there too many heat sources or too many people in the room during cooling
operation?
Limited Warranty