Bol media Coo1 Carbon Monoxide Alarm
Where to Locate
- A CO alam should be centrally located outside of each sleeping ares in the immediate vicinity of all bedrooms For added protection, install ackditional C0 alarms in each separate bedroom. and on each level of your home
- If your bedroom hallway is longer than 40 feet (12 meters), install a CO alarm at BOTH ends of the hallway.
- In a single-level house, install at least one CO alarm near or within each separate sleeping area. For added protection, install an additional cO alam at feast 20 feet (6 meters), way from ariy furnace dir fuel Durning heat source
- In multi-level houses, in addition, lo (3) above, install at least one CD Alam near or within each separate sleeping area. For added protection install al least ana CO alarm on each level of the hose. If you have a demerit, install a CO alarm at the top of the basement stairs basement
Technical Specifications
Locations to Avoid
Improper location can affoct the sensitive electronic components in thin alam. To avoid causing damage to tho unit, to provide optimum performance and to prevent unnecessary nuisance famous, do not locats CO alarms in the following areas
- In garages or in any extremely dusty, dirty or greasy areas
- Where there is tho possibility of smoke or fumes under normal operating circumstances
- In poorly ventilated kitchens, garages and fumace rooms Koep the CO alarms at least 20 feet (6 meters) trom potential smoke or fume soutoes (e g stoves, furnaces, wator heaters, oppose heater it pOssible
- areas where a 20-oot (6-mater) distance trom a potential smote or fume source is not possible In modular, mobile or smaler houses, it is recommended the CO alarm be placed as far from any potnntial smoke or fumes sources
- Within 5 teet (1.5 motors) of any cooking appliance
- In extremely humic aroas. This alarm should be at least 10 feet (3 meters) from bath or shower, sauna, humidifier, vaporizer dishwasher, laundry room, utility room or another source of high humidity.
- In areas where the temperature in colder than 40″F (44 C) or hotter than 100 “F (37.8C) For example. non-airconditioned crew species, unfinished attics, uninsulated or poorly insulated ceilings,porches and garages
- where the ar turbulent, such as near ceiling fans, heat vents, air conditioner verits frush air return vent, or open windows, Excessive ai flow may prevent any Co from reaching the senso
- In direct sunlight
**Installation
**
Installing the battery
-
Instal the 9V alkaline battery When the battery is installed, the unit will beep one time and the red, green and yellow LEDs wil flesh in sequence, will be displayed on the screen wiltfh a blue backlight. In minutes, the backlight wil turn off and the green light will Rash every 60 seconds indicating that the unit is operational.
Important note -
Wall mounting
Drill holes of 1.1in (28 mm) or deeper at the marks using a 1/4 in (6 mm) drl bit -
Strike the two plastic plugs into the hoies with a hammer and insert the screw
-
Hook he CO alarm onto the screw