DEWALT DXIRFFP32 Disposable Particulate Respirator Face Masks Instruction Manual

June 13, 2024
Dewalt

DEWALT-logo

DEWALT DXIRFFP32 Disposable Particulate Respirator Face Masks

Product Information

The product is a set of DXIRFFP32, DXIRFFP35, DXIRFFP310, DXIRFFP22, DXIRFFP25, and DXIRFFP210 models. These models are designed to provide a specific functionality.

  • DXIRFFP32
    The DXIRFFP32 model is designed for…

  • DXIRFFP35
    The DXIRFFP35 model is designed for…

  • DXIRFFP310
    The DXIRFFP310 model is designed for…

  • DXIRFFP22
    The DXIRFFP22 model is designed for…

  • DXIRFFP25
    The DXIRFFP25 model is designed for…

  • DXIRFFP210
    The DXIRFFP210 model is designed for…

Product Usage Instructions

  1. Step 1:
  2. Step 2:
  3. Step 3:
  • DEWALT-DXIRFFP32-Disposable-Particulate-Respirator-Face-Masks-01 \(2\)See user information before use.
  • DEWALT-DXIRFFP32-Disposable-Particulate-Respirator-Face-Masks-01 \(3\)Humidity of storage conditions
  • Storage temperature
  • DEWALT-DXIRFFP32-Disposable-Particulate-Respirator-Face-Masks-01 \(5\)Expiry Date:
  • CE2797
  • DEWALT-DXIRFFP32-Disposable-Particulate-Respirator-Face-Masks-01 \(7\)UKCA0086

RESPIRATOR FITTING INSTRUCTIONS

  1. STEP 1
    Hold the DEWALT respirator in one hand with the nosepiece at your fingertips, allowing the top headband to hang freely. Hold the bottom headband above the respirator with your other hand.

  2. STEP 2
    Pull the bottom headband over your head and position below your ears. Press the DEWALT respirator firmly against your face with the nosepiece over the bridge of your nose.

  3. STEP 3
    Stretch and position the top headband high on the back of the head. Pull on the ends of the straps to tighten and achieve the required fit.

  4. STEP 4
    Using both hands, mould the nosepiece to the shape of your nose.

  5. STEP 5
    To test fit:

  6. Cup both hands over the DEWALT respirator being careful not to disturb the position, and b) inhale vigorously. If air leaks around the edges, reposition the straps or adjust the strap tension where applicable for a better fit. If there are still noticeable leaks, then this mask may not be suitable for you, and we advise you to seek another style from the DEWALT range.

Caution: The DEWALT respirator should be fit checked prior to each time it is worn.

  • Type-examination (Module B) by: BSI Group The Netherlands B.V. (NB 2797) Say Building, John M. Keynesplein 9, 1066 EP Amsterdam, Netherlands.
  • Conformity to type (Module D) by : BSI Group The Netherlands B.V. (NB 2797) Say Building, John M. Keynesplein 9, 1066 EP Amsterdam, Netherlands.
  • UKCA type-examination (Module B) by : BSI Group UK (AB0086) Davy Avenue Knowlhill, Milton Keynes, MK5 8PP, United Kingdom
  • UKCA conformity to type (Module D) by: BSI Group UK (AB0086) Davy Avenue Knowlhill, Milton Keynes, MK5 8PP, United Kingdom
  • LOT NO. / MFG Date:
  • NR -For Single Shift Use Only
  • Maximum of 8 Hours Usage

D – Dolomite tested

  • For use against solid & liquid aerosols.
  • See information supplied by the manufacturer.

EU declaration of conformity present on the website www.dewalt.com PPE Regulation (EU) 2016/425

WARNING

Please read and understand before use.

  1. A properly selected respirator is essential to protect your health. Before using this product consult a safety professional to determine its suitability for your intended application.
  2.  As with any respiratory device, the wearer MUST be adequately trained prior to use. Before use, the wearer should always check the mask is in good condition – no dirt, no damage to head strap attachment etc.
  3. This product does not protect the wearer against gases, vapours or mist whose liquids produce harmful vapours or gases.
  4. Do not use in sandblasting operations.
  5. This product does not supply oxygen. Use this respirator only in well-ventilated areas containing sufficient oxygen (at least 19.5%) to support life.
  6. Do not use when the contaminant and the concentration are unknown or immediately dangerous to life and health.
  7. Leave the work area immediately if: a) breathing becomes difficult, b) dizziness or other distress, c) the respirator becomes damaged or d) an emergency occurs.
  8. If the user experiences any illness or discomfort, consult a licensed medical doctor to determine suitability of use.
  9. Facial hair and certain facial characteristics will prohibit the effective use of this product.
  10. Replace the respirator when the breathing resistance becomes excessive due to dust loading or after a maximum of 8 hours continuous usage, “single shift use”.
  11. Failure to observe all warnings and instructions on the use of this respirator may result in serious illness or permanent injury.
  12. The equipment should not act as an ignition source, and it should not be used in explosive atmospheres as the concentration of contaminants within the normal flammability range would exceed the limits in the selection guide.
  13. Store the respirator in a sealed container away from contaminated areas when not in use.
  14. Store the respirator in the original packaging during transportation.
  15. Please make sure the mask fits property before entering the working environment.

WARRANTY

  • Gentex warrants that this Product will be free from defects in material or workmanship under normal use and service for a period of one (1) year from the date of delivery when installed properly and used normally and in accordance with written operating instructions, if any (“Limited Warranty”). All repair covered by this Limited Warranty shall be performed at Gentex’s factory, or other such warranty repair facilities of Gentex as designated by Gentex unless Gentex specifically directs that repair services be performed at another location. All Products returned under this Limited Warranty must be returned within sixty (60) days of generation of a Return Material Authorization (RMA) by Gentex. Any defect corrected and found to be within this scope of the Limited Warranty will be repaired by Gentex and all charges for labor and material will be borne by Gentex. If it is determined that either no fault exists in Gentex, or the damage to be repaired was caused by your negligence or the negligence of your agents, employees or customers you agree to pay all charges associated with each such repair and shipping costs. No statement, recommendation or assistance made or offered by Gentex through its representatives to you, your agents, employees, or customers in connection with the purpose or intended use of any Gentex product shall be or constitute a waiver by Gentex of any of the provisions of this Limited Warranty or change Gentex’s liability under this Limited Warranty.
  • EXCEPT AS SET FORTH IN THE LIMITED WARRANTY CONTAINED HEREIN, YOU TAKE THE PRODUCT “AS IS”. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES OR CONDITIONS BEYOND THOSE STATED IN THIS LIMITED WARRANTY. GENTEX DISCLAIMS ALL OTHER WARRANTIES AND CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO THE FULLEST EXTENT PERMISSIBLE BY LAW, GENTEX SHALL NOT BE LIABLE FOR ANY INJURY OR DAMAGE TO PERSONS OR PROPERTY OF ANY KIND, OR FROM ANY LOSS OF TIME, INCONVENIENCE, OR LOSS OF USE, INCLUDING ANY CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING DIRECTLY OR INDIRECTLY OUT OF OR IN CONNECTION WITH THE USE, INSTALLATION AND/OR PERFORMANCE OF THE PRODUCTS, EVEN IF GENTEX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

DECLARATION OF CONFORMITY

  • EU declaration of conformity present on the website:
    www.dewalt.com PPE Regulation (EU) 2016/425

  • UKCA declaration of conformity present on the website:
    www.dewalt.com Regulation 2016/425 on personal protective equipment as brought into UK law and amended (for UKCA)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Dewalt User Manuals

Related Manuals