ESCHENBACH 11446 ridoMED-teleMED Galilean Systems User Manual

June 13, 2024
ESCHENBACH

ESCHENBACH 11446 ridoMED-teleMED Galilean Systems

ESCHENBACH-11446-ridoMED-teleMED-Galilean-Systems-
PRODUCT

OVERVIEW

ESCHENBACH-11446-ridoMED-teleMED-Galilean-Systems-
FIG-1

  • You have selected a quality product from the house of Eschenbach which has been produced using the latest manufacturing processes in Germany, a top-class „Made in Germany” product. We congratulate you on your choice.
  • Various pre-assembled binocular systems are available from Eschenbach:
  • Magnifying spectacles for near viewing rido-med binocular (with convergence positions)
  • Magnifying spectacles for far viewing tele-med binocular (with parallel positions)

Safety instructions

  • Danger of fire Lenses used in optical equipment may cause considerable damage through their ,burning glass effect” if used or stored incorrectly. Ensure that optical lenses are never left uncovered in the sunlight!
  • Danger of blinding or injury Never look at the sun through any optical equipment!
  • Danger of tripping when wearing magnifying spectacles or telescopic spectacles!
  • Protect your magnifying spectacles or telescopic spectacles from knocks, bangs, moisture and excessive heat!
  • When focusing the lenses, do not rotate past the limit stop!

Adjusting the binocular system

  • Anatomical adjustments are carried out by the eyeglass optician.
  • Anatomical adjustments
  1. Adjust side length.
  2. Inclination (Frame angle}: adjust to suit head position of user.

Adjustment of pupil distance (PD}

  1. Adjust the near / far PD using the scale [2] set on the eye-side of the binocular carrier [1].
    • The viewing field of both eyes must coincide, i.e. only one clear image must appear.
    • Fit the Galilei systems as closely as possible to the eye to ensure the maximum possible viewing field for the user.
  2. Once the PD has been set, lock the eyepiece holders [3] with the clips [4].

Adjust for viewing errors

  • The system can be corrected at the eye-side (far correction}.
  • For eye-side correction, use the accessories from Article No. 16221
  • (Former for spectacle glasses with 4 replacement attachment rings).
  1. Grind the correction lenses to 22 mm.

  2. Attach correction lenses using the attachment rings to the eye-side of the system.

    • If eye-side correction is not necessary, the eyepiece cups [5] can be fitted with caps [6].
      If required, the adjustment supplement in the Eschenbach brochure
      Adjustment of magnifying viewing aids” Article No. 162510 gives additional information.
  3. The focusing ring can be rotated [7] for accurate focusing.

    • The focusing positions in the system can be used to compensate spherical correction (Dioptric compensation 5 Dpt.).
    • The focusing ring is difficult to rotate in order to prevent the focus setting from changing by itself.

Instructions for care

  • The magnifying/telescopic spectacles should be kept in their case when not in use.
  • Clean the lenses with a soft, lint-free cloth (e. g. lens cleaning cloth), for harder to remove dirt (e. g. finger prints) use commercially available cleaning products.

Technical data

rido-med 16362 16363 16364
Magnification 2.5 X 3.0 X 4.0 X
Viewing field values *) Near (mm) 91/350 54/200 34/250
Viewing angle 15.0° 12.5° 8.0°
Working distance (mm)

˜ 350

|

˜ 200

|

˜ 250

Lens 0| 23 mm
Weight| 70 g
Dioptric|

˜ 5 dpt.

compensation
rido-med| 16362| 16363| 16364
---|---|---|---
Magnification| 2.5 X| 3.0 X| 4.0 X
Viewing field values *) Near (mm)|

91/350

|

54/200

|

34/250

Viewing angle| 15.0°| 12.5°| 8.0°
Working distance (mm)| ˜ 350| ˜ 200| ˜ 250
Lens 0| 23 mm
Weight| 70 g
Dioptric| ˜ 5 dpt.
compensation

The effective viewing field in the Galilei systems is dependent on the distance between the eye and the eyepiece. Therefore, the viewing field values given are average values (Viewing angle was measured at HSA [cornea-lens distance] 10 mm).

Guarantee

We are required by law to guarantee the function of the product described in these descriptions in respect of defects caused by manufacturing or material faults. Any damages caused by incorrect handling, including damage caused by being dropped or knocked, are not covered under the guarantee. Guarantee benefits can only be claimed through proof of purchase in the form of a sales receipt!

Date

  • Company stamp and signature of dealer
  • For the authorized representative in your country please refer to www.eschenbach-optik.com

Documents / Resources

| ESCHENBACH 11446 ridoMED-teleMED Galilean Systems [pdf] User Manual
11446 ridoMED-teleMED Galilean Systems, 11446, ridoMED-teleMED Galilean Systems, teleMED Galilean Systems, Galilean Systems
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals