FIAMMA 80005576 Roof Hood Vent Instruction Manual

June 13, 2024
FIAMMA

FIAMMA 80005576 Roof Hood Vent Instruction Manual
Roof Hood Vent

| | __
---|---|---
__ Vent White| 04328B01-| __** 2,8 kg
04329B02-
** Vent Crystal| 04328B01D
04329B02D

Product Parts
Tools
Dimension

Check that nothing has been damaged or deformed during transport.In the event of doubts or questions concerning the installation, use or limitations of the product, contact the dealer. We recommend that the installation is carried out by qualifi ed personnel and in compliance with current local regulations.

STANDARD

Dimension
OPTIONAL – KIT EXTENSION VENT
Ivory – Item No. 98683-116
White – Item No. 98683-112
Dimension
OPTIONAL – KIT EXTENSION VENT
Ivory – Item No. 98683-116
White – Item No. 98683-112
Dimension
Product Installation

  1. Decide where the roofl ight should be installed and make a square hole of 39cm. The roofl ight can be installed on roofs with thickness between 3 and 5cm. The optional Extension Vent kit must be used for fi xings with thicknesses greater than 5 cm up to max 8.5 cm.
    Dimension

  2. Apply the waterproof sealant (recommended: SIKALASTOMER-710 / THEROSTAT II / DEKALIN 1512) in the lower part of the external frame. Clean the roof area perfectly.
    Apply waterproof

  3. Insert the outside of the roofl ight into the opening paying attention to turn the hinges in the direction of travel. Press lightly the external frame on the roof in order to distribute the sealant evenly, if necessary.

  4. Fix it with 20 screws Ø4.2x30mm UNI EN ISO 7049 (not supplied)
    Dimension

  5. Carefully siliconate all the perimeter of the external frame, fi ll any spaces between the roof and the frame and all the heads of the 20 screws. Insert the internal frame into the opening and fi x it with 4xØ3.5x15mm self-tapping screws UNI EN ISO 7049 (not supplied).
    Dimension
    Remove the protective plastic applied to the cover (do not expose the product to sunlight for too long to avoid to make this operation diffi cult).

In case of problems please contact your local dealer. Consult our website for spare parts drawing..
Qr Code
https://www.fiamma.it/en/spare-parts-comfort/rooflights/vent-white-ivory-en

Product Instruction
Fiamma declines all responsibility for any personal injury and damage to property due to incorrect assembly or use of the product; it is suggested to keep the instructions inside the vehicle. The assembly of the product must be carried out according to the assembly instructions: the product must not be modifi ed in any way. Before proceeding with assembly, check that the roof thickness is compatible with the product.
Before choosing the place where to assembly the roofl ight, check that:

  • The product doesn’t interfere with adjacent accessories (luggage racks, cables, reinforcements in the roof, cabinets inside the passenger compartment).
  • the internal and external surface of the roof is fl at. Periodically check the tightness of all the screws in the roofl ight, especially after the fi rst kms from the installation and each time before and after long journeys. Lubricate the lid opening device with a few drops of grease if it becomes hard. If the opening-closing device hardens, lubricate the lid opening device with a few drops of grease It is forbidden to walk on the product’s cover. Before starting the vehicle, check that the roofl ight is properly closed. Periodically check that the cover is intact. Don’t open the roofl ight when the vehicle is travelling Don’t open the roofl ight in case of strong wind or rain. Remove snow or ice from the roofl ight. Always comply with speed limits and the Highway Code. The speed should always be suitable to traffi c conditions and transported load.

CARE AND MAINTENANCE:

For the internal and external cleaning of the roofl ight, always use only neutral, non-aggressive detergents. For cleaning the Crystal cover use an acrylic glass cleaner with a soft cloth so as not to scratch the surface. Never use aggressive products such as glass cleaners, all-purpose cleaners, abrasives or dish-washing detergents. Also, never use alcohol-containing detergents, solvents or any corrosive liquid. The mosquito net can be cleaned with water and neutral detergent, removing the frame and the fi xing screws.

EXTENSION VENT IVORY
Item No. 98683-116
EXTENSION VENT WHITE
Item No. 98683-112

SPOILER UNIVERSAL
Item No. 06289-01-
Dimension

THERMO VENT 40
Item No. 03650A01-
Dimension

ROLLO VENT 40
Item No. 06310-02-
Dimension

Warranty Fiamma
In case of defects with regards to materials and manufacturing, the customer is entitled to the warranty in accordance with local laws and regulations of the country in which the product was purchased.

Fiamma S.p.A. – Italy
Via San Rocco, 56
21010 Cardano al Campo (VA)

https://www.fiamma.it/en/

All rights reserved.
Fiamma S.p.A.
reserves the right to modify at any time, without notice, prices, materials, specifi cations and models or to ceaseproduction of any model.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FIAMMA User Manuals

Related Manuals