intense LIGHTING IS-R1090R2 SD 4-inch Remodel Downlights Instruction Manual
- June 5, 2024
- intense LIGHTING
Table of Contents
intense LIGHTING IS-R1090R2 SD 4-inch Remodel Downlights
IMPORTANT SAFETY INSTRUCTIONS
- Read all installation instructions before installing. It is important to save these instructions.
- Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power on, could damage the LEDs and is not covered by warranty.
- Observe and follow all label information and instructions regarding dry, damp, and wet location listings, proper Intense LED module, warnings of installation near combustible materials, and/or insulation.
- Turn off power at circuit breaker before attempting to install or perform maintenance on the fixtures.
- Be sure to connect the ground wire to prevent electric shock or other potential hazards.
- The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local codes by a person familiar with the construction and operation of the product and the hazards involved.
- Do not block the trim aperture as this may cause unsafe operating conditions.
- WARNING: RISK OF FIRE. Non-IC fixture requires that insulation must be kept at least 3” away from all sides of the fixture. Minimum of 90°C supply conductors. Consult a qualified electrician before installation.
- WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a violation of N.E.C 110-3(B) and voids all warranties.
WARNING:
- Risk of electrical shock. Disconnect power before servicing or installing luminaire
- Risk of injury or damage. The luminaire will fail if not installed properly. Follow installation instructions.
- Risk of injury. Wear safety glasses and gloves during installation and servicing. Allow ample time to cool before handling.
Ceiling Cut-Out Information:
CEILING CUT OUT:
- Cut out 4 3/4” diameter ceiling holes for remodeling housing.
Note: Remodel housings are Non-IC rated and insulation must be kept at a minimum of 3” away from the fixture.
ELECTRICAL CONNECTIONS:
- Remove junction box plate and make electrical connections through the desired knockout for conduit or Romex® cable. Use only UL-listed connectors.
- Connect the black wire from the fixture to the black (HOT) supply wire, the white wire from the fixture to the white (NEUTRAL) supply wire, and connect the ground from the fixture to the green (GROUND) supply wire. Use UL-listed connectors or wire nuts to make the connections (provided by others). Connect dimming wires if applicable, see page 4.
- Close and lock junction box door ensuring all wire connections and wire are contained within.
Fixture Install:
- Push tension springs up into the housing towards the fixture.
- Lift up the housing bracket with the junction box and push it thru the opening on a ceiling.
Fixture Install:
- Once the junction box went thru the opening, pull down the housing bracket with the junction box and let it sit on ceiling.
- Use the flat head screwdriver to push tension springs to secure the ceiling.
- Make sure the housing collar is flush with the ceiling line.
Installation Instructions
TRIM INSTALLATION:
- Push trim into housing ensuring the trim is flush to the ceiling.
- Once all fixtures have been installed, power at the breaker can be restored.
Servicing
TRIM Removal:
- Remove the trim from the housing
Fixture Removal:
- Push tension springs up into the housing towards the fixture.
Fixture Removal:
- Pull down fixture thru the opening on a ceiling.
Fixture Removal:
- Once the fixture is out of the ceiling, push down the spring clip on the junction box and unlock the driver plate.
- Remove the driver plate from the junction box and disconnect the driver.
WIRING & DIMMING COMPATIBILITY
For use with all Intense Lighting products with supported dimming options.
Please check the configuration of the product for the correct dimming
protocol.
Phase Dimming or Lutron® LTEA2W Hi-Lume 2-Wire
- 120V Only
- Forward 1% / Reverse 5%
COMPATIBLE DIMMERS
- Product Part Number(s) Type
- Leviton IPE04 Reverse
- Leviton IPI06-1LZ Forward
- Leviton 6633-P Forward
- Lutron DVELV300P Reverse
- Lutron DVCL-153P Forward
- Lutron S600P Forward
- Cooper DLC03P Forward
- Cooper DAL06P Forward
0-10V Dimming
- 120V or 277V
- Dims down to 1% or 0.1% light output
- Consult dimming manufacturer for installation instructions and power packs
COMPATIBLE DIMMERS Manufacturer Part Number(s)
- HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V,
- PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V,
- FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV,
- PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V
- Leviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212
- Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU
- Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC
- Lutron DVTV, NTFTV
- Synergy ISD BC 120/277
Lutron® LDE1 Hi-Lume EcoSystem
- 120V or 277V
- Dims down to 1%
- Consult dimming manufacturer for installation instructions
COMPATIBLE DIMMERS
- Product Part Number(s)
- EcoSystem CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM,
- EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum
DMX512 RDM (Downlights with RJ45)
- 120V or 277V
- Dims Down to 0.1% Light Output
- RDM Channel Programmable
WIRING & DIMMING COMPATIBILITY
For use with all Intense Lighting products with supported dimming options.
Please check the configuration of the product for the correct dimming
protocol.
DMX512 RDM (Cylinders without RJ45)
- 120V or 277V
- Dims Down to 0.1% Light Output
- RDM Channel Programmable
0-10V With Dynamic Beam
- 120V or 277V
- Dims down to 1% or 0.1% light output
- Consult dimming manufacturer for installation instructions and power packs
COMPATIBLE DIMMERS
Manufacturer Part Number(s)
- HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V,
- PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V,
- FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV,
- PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V
- Leviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212
- Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU
- Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC
- Lutron DVTV, NTFTV
- Synergy ISD BC 120/277
0-10V With Tunable White
- 120V or 277V
- Dims down to 1% or 0.1% light output
- Consult dimming manufacturer for installation instructions and power packs
COMPATIBLE DIMMERS
Manufacturer Part Number(s)
- HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V,
- PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V,
- FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV,
- PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V
- Leviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212
- Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU
- Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC
- Lutron DVTV, NTFTV
- Synergy ISD BC 120/277
DALI With Tunable White
- 120V or 277V
- Dims down to 0.1%