Waiver number: RFW-001246
SolarEdge Product Waiver Approval
Issue date: 21st November 2022
Dear Installer,
Upon examining your waiver request, SolarEdge decided to approve it under the
following conditions:
a. This approval is limited only to installations done in Europe (including
the UK).
b. The approved designs are as follows:
a. The connection of the P850 / P950 / P1100 Optimizers with any module that
has an Isc value between 14.1A to 14.5A.
b. The modules connected to the Optimizers do not exceed the approved rated
input DC Power.
c. For modules with 54 cells (or 108 half-cells):
Inverter | Strings | Minimum number of modules connected in each string |
---|---|---|
SE16K | 1 | 31 |
SE17K | 1 | 31 |
SE2OK | 2 | 27 |
SE25K* | 2 | 29 |
SE27.6K* | 2 | 32 |
SE3OK* | 2 | 35 |
SE33.3K* | 3 | 27 |
d. For modules with 60 cells (or 120 half-cells):
Inverter | Strings | Minimum number of modules connected in each string |
---|---|---|
SE16K | 1 | 29 |
SE17K | 1 | 29 |
SE20K | 2 | 27 |
SE25K* | 2 | 27 |
SE27.6K* | 2 | 29 |
SE30K* | 2 | 32 |
SE33.3K* | 3 | 27 |
e. With regards to the above tables, when connected to a higher number of
strings per inverter, the minimum number of modules per string is 27.
f. For modules with 72 cells or more – all regular configurations are allowed.
c. The rest of the installation guidelines and the Power Optimizer’s
performance remain as stated in the SolarEdge specifications and installation
documents.
- Or their equivalent Synergy unit
SolarEdge approves that the designs mentioned above, though exceeding the Power Optimizer maximum
Isc current limit (up to 14.5A vs. 14.1A), will not void the Power Optimizer or Inverter warranty.