JBC JTSE-1UA (100V – 120V) Power Hot Air Control Unit Instruction Manual
- June 13, 2024
- JBC
Table of Contents
- JTSE-1UA (100V – 120V) Power Hot Air Control Unit
- Packing List
- Features and Connections
- Troubleshooting
- Advanced Functionalities
- System Notifications
- Adjustable Stand
- Operation
- Protectors & Extractors
- Accessories (not included)
- Compatible Nozzles
- Replacing the Heating Element
- Maintenance
- Safety
- Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
www.jbctools.com
INSTRUCTION MANUAL
JTSE-1UA (100V – 120V) Power Hot Air Control Unit
JTSE
Power Hot Air Control Unit
This manual corresponds to the following references:
JTSE-1UA (100V / 120V)
JTSE-2UA (230V)
Packing List
The following items are included:
Power Hot Air Control Unit …………………. 1 unit
Power cable ………………………………………….1 unit
Ref. 0023715 (100V / 120V) 0023714 (230V)
Manual … …………………………………………………1 unit
Ref. 0030011
Features and Connections
JTSE / TESE Work Screen
The work screen offers an intuitive user interface which provides quick access
to station parameters. Default PIN: 0105
Troubleshooting
Station troubleshooting available on the product page at www.jbctools.com
Advanced Functionalities
By pressing Graphics in the main MENU, temperature and power figures in
real time are displayed. This helps you decide which nozzle to use to obtain
the best quality solder joints.
The first system to optimize traceability in soldering
– Get greater quality and control in your production
– Manage your whole soldering process remotely in real time
Station Update
Download the JBC Update File from
www.jbctools.com/software.html Insert
the USB flash drive with the file downloaded to the station.
System Notifications
The following icons will be displayed on the screen’s status bar.
| USB fl ash drive is connected.
---|---
| Station is controlled by a PC.
| Station is controlled by a robot.
| Station software update.
Press INFO to start the process.
| Warning.
Press INFO for failure description.
| Error.
Press INFO for failure description, the type of error and how to proceed.
Adjustable Stand
Adjust the tool holder angle to suit your work position.
Operation Modes
- From the Tool Settings Menu, select the mode to activate the tool depending on the task.
- The tool stops blowing when pressing the start/stop button.
If the stand is connected to the station and for safety it will also stop when returned to the stand.
Operation
1. Placing | 2. Heating | 3. Extracting |
---|---|---|
Position the extractor with the appropriate suction cup and press the suction button.| Heat the component.| The component lifts off automatically when the solder melts.
Protectors & Extractors
For small components (fig. 1 and 2).
We recommend using the protector + tripod
For large components (fig. 3 and 4).
We recommend using the manual extractors
Accessories (not included)
Protectors
No.| Ref.| AxB (mm)| AxB (in)| No.| Ref.|
AxB (mm)| AxB (in)
---|---|---|---|---|---|---|---
| P3353| 4,3 x 3| 0.16 x 0.12| | P1249| 12 x 23| 0.47 x 0.9
| P3786| 5,2 x 5,2| 0.20 x 0.20| 44| P4000| 12,5 x 12,5| 0.49 x 0.49
| P3352| 5,2 x 7,5| 0.20 x 0.29| | P3354| 13,2 x 13,2| 0.52 x 0.52
| P3355| 5,2 x 9,5| 0.20 x 0.37| | P4025| 13,5 x 21,5| 0.53 x 0.85
| P3356| 6,2 x 4,2| 0.24 x 0.16| 48| P2230| 15 x 15| 0.59 x 0.59
| P3785| 7,2 x 7,2| 0.28 x 0.28| 60| P4010| 17 x 17| 0.67 x 0.67
| P3784| 8,2 x 8,2| 0.32 x 0.32| | P4005| 18 x 29| 0.71 x 1.14
| P4035| 9 x 13| 0.35 x 0.51| | P4030| 18,5 x 18,5| 0.73 x 0.73
| P4040| 9,5 x 19| 0.7 x 0.74| | P1068| 18,5 x 24| 0.73 x 0.94
| P4080| 9,5 x 21| 9.5 x 0.83| | P2685| 28,5 x 28,5| 1.12 x 1.12
32| P2220| 10 x 10| 0.39 x 0.39| | P4085| 31,5 x 31,5| 1.24 x 1.24
| P4045| 10,5 x 21| 0.14 x 0.82| | P2672| 33 x 46| 1.30 x 1.18
| P4090| 11 x 16| 0.43 x 0.63| | P4002| 50 x 50| 1.97 x 1.97
24| P2235| 12 x 17| 0.47 x 0.67| | P3357| 52,5 x 14| 2.06 x 0.55
Extractors
No.| Ref.| AxB (mm)| AxB (in) No.| Ref.| AxB
(mm)| AxB (in)
---|---|---|---|---|---|---
52| E2052| 20 X 20| 0.79 x 0.79| | E4015| 31,5 X 31,5| 1.24 x 1.24
64| E2064| 20 X 26| 0.79 x 1.02| | E2084| 33 X 33| 1.30 x 1.30
80| E2184| 24 X 24| 0.94 x 0.94| | E2100| 38 X 38| 1.50 x 1.50
| E2068| 27 X 27| 1.06 x 1.06| | E2124| 45 X 45| 1.77 x 1.77
| E4020| 28,5 X 28,5| 1.12 x 1.12| |
Tripods
Ref. | øC (mm) | øC (in) |
---|---|---|
T2050 | 39 | 1.53 |
T2250 | 85 | 3.35 |
Manual extractor
Ref. | øD (mm) | øD (in) |
---|---|---|
E2190 | 7 | 0.27 |
Using the Thermocouple Type K
Connect a TC type K (PH218) to the station and use it as a protection or
regulation sensor.
You can define its use mode by means of the “Ext TC mode” option in the “Tool”
menu.
You can choose from two work modes:
Regulation: the station regulates the air temperature automatically to
maintain the External Thermocouple (TC) temperature.
Protection: the station cuts the air supply off when the External
Thermocouple (TC) temperature is reached.
Fix the TC with Kapton Tape (Ref. PH217) as near as possible to the component
being worked on. If Kapton tape is not ESD you must use an ionizer.
IPC* does not recommend exceeding ramp-up rates over 3-4ºC / sec. (5-7ºF / sec) so as to reduce the risk of thermal stress on the PCB.
- IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits.
Nozzle Extractor
Turn the tool off and handle it with care. The heating element and the nozzle
are still hot.
- Removing Nozzle Place the heating element with its nozzle in the nozzle changer and pull the tool to remove it. The nozzle comes to rest in the nozzle storage.
- Attaching Nozzle Attach the nozzle and press the nozzle onto the heating element with the help of the opening in the nozzle changer.
Compatible Nozzles
JTT works with JT nozzles. Find the model that best suits your soldering needs at www.jbctools.com
* | Ref. | Shape | Size (mm) | Size (in) |
---|---|---|---|---|
* | JN2020 | Straight | Ø 8 | Ø 0.31 |
JN8417 | Straight | Ø 10 | Ø 0.4 | |
* | JN2015 | Bent | Ø 4 | Ø 0.16 |
* | JN2012 | Bent | Ø 6 | Ø 0.24 |
JN6633 | Bent | Ø 8 | Ø 0.31 | |
JN7637 | Flat | 10 x 2 | 0.39 x 0.08 | |
JN7638 | Flat | 20 x 2 | 0.79 x 0.08 | |
JN7639 | Flat | 30 x 2 | 1.18 x 0.08 |
- Supplied with JT
In case of a loosely fitting nozzle:
- Push the nozzle tab inwards with a screw-driver or flat-nosed pliers.
- Assemble the nozzle onto JTT again.
Replacing the Heating Element
Note: Only perform this operation when the element is cold and the unit
is disconnected from the mains.
Loosen the screw (1) and pull the worn heating element out of the handle (2).
Insert the new heating element, make sure its pushed all the way in (2) and
tighten the screw (1).
Changing the JTT Heater
Hose Set
Note: Only perform this operation when the station is turned off.
Use a spanner to unscrew the nut (1) and remove the tool hose from the control
unit (2). Insert the new hose, make sure it is
pushed all the way into the connector (2), and tighten the nut (1).
Maintenance
Before carrying out maintenance, always allow the equipment to cool.
– Clean the station screen with a glass cleaner or a damp cloth.
– Use a damp cloth to clean the casing and the tool. Alcohol can only be used
to clean the metal parts.
– Periodically check that the metal parts of the tool and stand are clean so
that the station can detect the tool’s status.
– Periodically check all cables and tubes.
– Replace a blown fuse as follows:
- Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off.
- Insert the new fuse into the fuse holder and return it to the station.
– Replace any defective or damaged pieces. Use original JBC spare parts only.
– Repairs should only be performed by a JBC authorized technical service.
Safety
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
– Do not use the units for any purpose other than soldering or rework.
Incorrect use may cause a fire.
– The power cord must be plugged into approved bases. Be sure that it is
properly grounded before use. When unplugging it, hold the plug, not the wire.
– Do not work on electrically live parts.
– The tool should be placed in the stand when not in use in order to activate
the sleep mode. The soldering tip or nozzle, the metal part of the tool and
the stand may still be hot even when the station is turned off. Handle with
care, including when adjusting the stand position.
– Do not leave the appliance unattended when it is on.
– Do not cover the ventilation grills. Heat can cause inflammable products to
ignite.
– Avoid flux coming into contact with skin or eyes to prevent irritation.
– Be careful with the fumes produced when soldering.
– Keep your workplace clean and tidy. Wear appropriate protection glasses and
gloves when working to avoid personal harm.
– Utmost care must be taken with liquid tin waste which can cause burns.
– This appliance can be used by children over the age of eight and also
persons with reduced physical, sensory or mental capabilities or lack of
experience provided that they have been given adequate supervision or
instruction concerning the use of the appliance and understand the hazards
involved.
Children must not play with the appliance.
– Maintenance must not be carried out by children unless supervised.
Notes
Specifications
JTSE
Power Hot Air Control Unit
Ref.: JTSE-1UA 100V – 120V 50/60Hz. Input fuse: 8A. Rated current: 7A
Ref.: JTSE-2UA 230V 50/60Hz. Input fuse: 4A. Rated current: 3A
– Temperature selection:
– Nominal power:- Cool mode:
– Ambient operating temp.:
– Air flow regulation:
– Vacuum:
– Connectors:
– Control Unit Dimension/Weight: (L x W x H)
– Total Net Weight:
– Total Package Dimension/Weight: (L x W x H)| Room temp. 150 – 450 °C / 300 –
840 °F
700W
T off. Used to blow air to room temperature
10 – 50 ºC / 50 – 122 ºF
5 – 50 SLPM
30% / 228 mmHg / 9 inHg
USB-B
RJ-12
P-005 Pedal
1.90 kg / 4.2 lb
230 x 148 x 160 mm / 5.83 x 7.24 x 5.51 in
258 x 328 x 208 mm / 2.56 kg
10.15 x 12.9 x 8.2 in / 5.64 lb
---|---
Complies with CE standards.
ESD safe.
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects,
including the replacement of defective parts and labor.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage
paid, to the dealer where it was purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/ within 30 days of purchase.
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at
the end of its life must be collected and returned to an authorized recycling
facility.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>