HYQUEST SOLUTIONS BLSH Handheld Bedload Sampler User Manual
- June 13, 2024
- HYQUEST SOLUTIONS
Table of Contents
BLSH Handheld Bedload Sampler
Product Information
The HyQuest Solutions BLSH is a precision instrument and data
logger designed for various applications. It is produced in
quality-controlled processes and is ISO 90001 certified. The device
is equipped with inputs and outputs that are protected against
electric discharges and surges (ESD). It comes with a bag support
shaft (BLSH02-01), wading rods (DH48-04), and a sample bag (SB-01)
for easy operation.
Product Usage Instructions
-
Assembly: To assemble the HyQuest Solutions
BLSH, follow these steps: -
Insert the dimple end of the bag support shaft (BLSH02-01) into
the boss on the body (BLSHOl-01). -
Screw in the wading rod (DH48-04) to lock the bag support shaft
in position. -
Screw in the second wading rod.
-
Attach the sample bag (SB-01) with the seam uppermost to the
rear of the body, ensuring the elastic band is located in the body
groove. -
Connect the hook to the eye in the rear of the sample bag.
-
Operation: To operate the HyQuest Solutions
BLSH, follow these steps: -
Ensure that all components are securely assembled.
-
Follow the specific instructions for your application to
collect and measure data using the device. -
Repair: In case of any errors or issues with
the HyQuest Solutions BLSH, please follow these guidelines: -
Report any errors found in the product to HyQuest Solutions for
quick resolution. -
Refer to the warranty policy provided by HyQuest Solutions for
repair or replacement options. -
Obligations of the Operator and Disposal:
After the BLSH is taken out of service, it must be disposed of in
compliance with local waste and environmental regulations. Do not
dispose of the device in household waste.
Please note that this is a summary of the product information
and usage instructions. For detailed information, refer to the
complete user manual provided by HyQuest Solutions.
BLSH
User Manual
04-2023 01-02-000
Table of Contents
I II III
Part I Part II Part III Part IV Part V Part VI
6.1 6.2
Part VII
Disclaimer
3
Scope of Delivery
4
Safety Instructions
5
Introduction
6
Assembly
7
Operation
8
Repair
9
Technical Data
10
Obligations of the Operator and Disposal
11
Obligations of the Operator ……………………………………………………………………………………………………….. 11
Dismantling / Disposal ……………………………………………………………………………………………………………….. 11
Appendices
13
© 2023 HyQuest Solutions
2
I
Disclaimer
The information provided in this manual was deemed accurate as of the
publication date. However, updates to this information may have occurred.
This manual does not include all of the details of design, production, or
variation of the equipment nor does it cover every possible situation which
may arise during installation, operation or maintenance. HyQuest Solutions
shall not be liable for any incidental, indirect, special or consequential
damages whatsoever arising out of or related to this documentation and the
information contained in it, even if HyQuest Solutions has been advised of the
possibility of such damages.
Any errors found in any HyQuest Solutions product should be reported to
HyQuest Solutions where every effort will be made to quickly resolve the
problem.
Copyright Notice: No parts of this work may be reproduced in any form or by
any means without the written permission of the publisher. HyQuest Solutions
waives copyright for users to print out parts of the documentation in hard
copy for their own use only.
Trademark Notice: HyQuest Solutions (HS) and KISTERS products and services
referred to in this document are trademarks or registered trademarks of
HyQuest Solutions or KISTERS AG. Other product names used may or may not be
the trademarks of their respective owners.
© 2020 HyQuest Solutions, a KISTERS Group Company. Any rights not expressly
granted herein are reserved.
This document is public.
© 2023 HyQuest Solutions
3
II Scope of Delivery
§ Sampler § 1 m wading rod (2 sections each 0.5 m), stainless steel
(additional 0.5 m sections available on request) § SB-01 sample bags (two
supplied) § Canvas carry bag for BLSH
© 2023 HyQuest Solutions
4
III Safety Instructions
§ Read the user manual including all operating instructions prior to
installing, connecting and powering up the HyQuest Solutions BLSH. The manual
provides information on how to operate the product. The manual is intended to
be used by qualified personnel, i.e. personnel that have been adequately
trained, are sufficiently familiar with installation, mounting, wiring,
powering up and operation of the product.
§ Keep the user manual on hand for later reference! § If you encounter
problems understanding the information in the manual (or part thereof), please
consult the
manufacturer or its appointed reseller for further support. § HyQuest
Solutions BLSH is intended to be used in hydrometeorological or environmental
monitoring applications. § Before starting to work, you have to check the
functioning and integrity of the system.
§ Check for visible defects on the BLSH, this may or may not include any or
all of the following mounting facilities, connectors and connections,
mechanical parts, internal or external communication devices, power supplies
or power supply lines, etc.
§ If defects are found that jeopardize the operational safety, work must be
stopped. This is true for defects found before starting to work as well as for
defects found while working.
§ Do not use the HyQuest Solutions BLSH in areas where there is a danger of
explosion. § The present user manual specifies environmental/climatic
operating conditions as well as mechanical and electrical
conditions. Installation, wiring, powering up and operating the HyQuest
Solutions BLSH must strictly comply with these specifications. § Perform
maintenance only when tools or machinery are not in operation. § If guards are
removed to perform maintenance, replace them immediately after servicing. §
Never make any electrical or mechanical diagnostics, inspections or repairs
under any circumstances. Return the product to the manufacturer’s named repair
centre. You can find information on how to return items for repair in the
relevant section of the HyQuest Solutions website.
§
Disposal instructions: After taking the HyQuest Solutions BLSH out of service, it must be disposed of in
compliance with local waste and environmental regulations. The HyQuest Solutions BLSH is never to be disposed in
household waste!
§
Inputs and outputs of the device are protected against electric discharges and surges (so-called ESD). Do not
touch any part of the electronic components! If you need to touch any part, please discharge yourself, i.e. by touching
grounded metal parts.
© 2023 HyQuest Solutions
5
Introduction
1 Introduction
Thank you for choosing our product. We hope you will enjoy using the device.
HyQuest Solutions manufactures, sells, installs and operates quality
instrumentation, data loggers and communication technology. Products are
designed with passion for environmental monitoring and with a deep
understanding of the quality, accuracy and robustness needed to fulfil the
requirements of measurement practitioners in the field. The present User
Manual will help you understand, install and deploy the device. If, however,
you feel that a particular information is missing, incomplete or confusing,
please do not hesitate to contact us for further support! HyQuest Solutions’
bed load sampler BLSH is an easy-to-use hand-held sampler for measuring and
analysing coarse sand, silt, gravel, rock or other insoluble materials carried
by a stream on or immediately above its bed.
© 2023 HyQuest Solutions
6
2 Assembly
Assembly
Insert dimple end of bag support shaft (BLSH02-01) into boss on body
(BLSHOl-01), screw in wading rod (DH48-04) to lock bag support shaft in
position. Screw in 2nd wading rod.
Attach sample bag (SB-01) with seam uppermost, to rear of body, ensuring
elastic band is located in body groove. Connect hook to eye in rear of sample
bag.
© 2023 HyQuest Solutions
7
Operation
3 Operation
§ Locate sampling points at the centroid of equal discharge panels in the
stream (by current meter measurement). § Place sampler on the stream bed
(being careful not to dig in the nozzle) with nozzle pointing upstream at
right angles
to crossing. § Collect a sample over a timed period, ensuring the sample bag
is not filled more than 40 %. § Record time and location. § Remove sample bag
and wet weigh sample. § Empty and wash out sample bag. § Continue sampling
operation.
© 2023 HyQuest Solutions
8
Repair
4 Repair
HyQuest Solutions precision instruments and data loggers are produced in
quality-controlled processes. All HyQuest Solutions production and assembly
sites in Australia, New Zealand and Europe are ISO 90001 certified. All
equipment is factory tested and/or factory calibrated before it is shipped to
the client. This ensures that HyQuest Solutions products perform to their
fullest capacity when delivered.
Despite HyQuest Solutions most rigorous quality assurance (QA), malfunction
may occur within or outside of the warranty period. In rare cases, a product
may not be delivered in accordance with your order.
In such cases HyQuest Solutions’ return and repair policy applies. For you as
a customer, this means the following:
1. Contact HyQuest Solutions using the Repair Request Form made available
online: https://cdn.hyquestsolutions.eu/fileadmin/Services/Downloads/HS-
RepairRequestForm_EU.pdf In response you will receive a reference number that
must be referenced on all further correspondence and on the freight documents
accompanying your return shipment.
2. Please provide as much information and/or clear instructions within the
return paperwork. This will assist our test engineers with their diagnosis.
3. Please do not ship the goods prior to obtaining the reference number.
HyQuest Solutions will not reject any equipment that arrives without reference
number; however, it may take us longer to process.
Custom requirements for items sent to HyQuest Solutions for warranty or non-
warranty repairs: Check with your national customs/tax authorities for
details, processes and paperwork regarding tax exempt return of products.
Typically, special custom tariff codes are available (such as HS Code =
9802.00) that verify the item is being returned for repair and has no
commercial value. Please note that the customs invoice / dispatch documents
should also clearly state: “Goods being returned to manufacturer for repair
No Commercial value”. It is mandatory to have any returned goods accompanied
by a commercial invoice on headed paper. HyQuest Solutions reserves the right
to charge the customer for time spent rectifying incorrect customs documents.
Note: Please ensure that your goods are packed carefully and securely. Damage
that occurs during transit is not covered by our warranty and may be
chargeable.
© 2023 HyQuest Solutions
9
5 Technical Data
Type Orifice Expansion Ratio Body Packed Dimensions
Technical Data
Handheld bed load sampler 76 × 76 mm 3.22 (exit area to entrance area) Epoxy
coated cast aluminium § Size: 60 × 30 × 30 cm § Volume: 0.03 m3 § Weight: 3 kg
© 2023 HyQuest Solutions
10
Obligations of the Operator and Disposal
6 Obligations of the Operator and Disposal
This chapter contains the following subsections: § Obligations of the Operator
11 § Dismantling / Disposal 11
6.1 Obligations of the Operator
European Union
In the Single European Market it is the responsibility of the operator to
ensure that the following legal regulations are observed and complied with:
national implementation of the framework directive (89/391/EEC) and the
associated individual directives, in particular 2009/104/EC, on minimum safety
and health requirements for the use of work equipment by employees at work.
Worldwide
Regulations: If and where required, operating licences must be obtained by the
operator. In addition, national or regional environmental protection
requirements must be complied with, regardless of local legal provisions
regarding the following topics: § Occupational safety § Product disposal
Connections: Local regulations for electrical installation and connections
must be observed.
6.2 Dismantling / Disposal
When disposing of the units and their accessories, the applicable local
regulations regarding environment, disposal and occupational safety must be
observed.
Before dismantling § Electrical Devices:
§ Switch off the units. § Disconnect electrical appliances from the power
supply, regardless of whether the appliances are connected to the
mains or to another power source. § Mechanical devices:
§ Fix all loose components. Prevent the device from moving independently or
unintentionally. § Loosen mechanical fastenings: Please note that appliances
can be heavy and that loosening the fastenings may
cause them to become mechanically unstable.
Disposal
Operators of old appliances must recycle them separately from unsorted municipal waste. This applies in particular to electrical waste and old electronic equipment. Electrical waste and electronic equipment must not be disposed of as household waste! Instead, these old appliances must be collected separately and disposed of via the local collection and return systems. Integrated or provided batteries and accumulators must be separated from the appliances and disposed of at the
© 2023 HyQuest Solutions
11
Obligations of the Operator and Disposal
designated collection point. At the end of its service life, the lithium-ion
battery must be disposed of according to legal provisions.
EU WEEE Directive
As players in the environmental market, KISTERS AG and HyQuest Solutions are
committed to supporting efforts to avoid and recycle waste. Please consider:
§ Avoidance before recycling!
§ Recycling before disposal!
This symbol
indicates that the scrapping of the unit must be carried out in accordance with Directive 2012/19/EU.
Please observe the local implementation of the directive and any accompanying or supplementary laws and regulations.
© 2023 HyQuest Solutions
12
7 Appendices
Appendices
© 2023 HyQuest Solutions
13
Appendices
© 2023 HyQuest Solutions
14
Appendices
© 2023 HyQuest Solutions
15
Appendices
© 2023 HyQuest Solutions
16
Appendices
© 2023 HyQuest Solutions
17
Appendices
© 2023 HyQuest Solutions
18
Contact Data
Europe
| HyQuest Solutions (KISTERS AG)
|
|
|
Australia
| HyQuest Solutions Pty Ltd
|
|
|
New Zealand | HyQuest Solutions NZ Ltd
|
|
|
Latin America | HyQuest Solutions (KISTERS LATAM) | | |
North America | Hydrological Services America LLC |
(KISTERS Group)
|
|
+49 2408 9385 0 info@hyquestsolutions.eu www.hyquestsolutions.eu
+612 9601 2022 sales@hyquestsolutions.com.au www.hyquestsolutions.com.au
+64 7 857 0810 sales@hyquestsolutions.co.nz www.hyquestsolutions.com.au
+57 350 575 4079 sales-latam@hyquestsolutions.com www.hyquestsolutions.es
+1 561 459 4876 sales-hsa@kisters.net www.hyquestsolutionsamerica.com
© 2023 HyQuest Solutions
www.hyquestsolutions.com © 2023 HyQuest Solutions 04/04/2023
References
- HyQuest Solutions | HyQuest Solutions / KISTERS
- HyQuest Solutions | HyQuest Solutions / KISTERS
- Catálogo de productos de KISTERS HydroMet
- KISTERS HydroMet Product Catalogue
- KISTERS North America HydroMet Product Catalogue
- HyQuest Solutions | HyQuest Solutions / KISTERS
- HyQuest Solutions | HyQuest Solutions / KISTERS
- Catálogo de productos de KISTERS HydroMet
- KISTERS HydroMet Product Catalogue
- KISTERS North America HydroMet Product Catalogue
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>