JBC CLMU-PB Automatic Tip Cleaner with Metal Fiber Brushes Instruction Manual
- June 13, 2024
- JBC
Table of Contents
- JBC CLMU-PB Automatic Tip Cleaner with Metal Fiber Brushes
- Product Information
- CLMU / CLMUP
- Packing List
- Features and Connections
- Keypad
- Operation
- Set Up
- Changing Brushes
- Accessories: Brush Range
- USB Connector
- Maintenance
- Safety
- Specifications
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
JBC CLMU-PB Automatic Tip Cleaner with Metal Fiber Brushes
Product Information
The CLMU / CLMUP Automatic Tip Cleaner is a device designed to clean soldering tips using metal or fiber brushes. It includes splashguard window, switch panel sensor window, locking tab, power cord socket, USB-B connector, ESD connector, and feet’s for vertical access. The device has a keypad with different operation modes and LED status indicators.
CLMU / CLMUP
Automatic Tip Cleaner with Metal/Fiber Brushes
This manual corresponds to the following references:
CLMU-A with metal brushes
CLMU-PB with fiber brushes (non-metal)
Packing List
The following items are included.
Automatic Tip Cleaner with
Metal/Fiber Brushes …………………………….. 1 unit
according purchased reference
Brush reference according purchased cleaner model. Brushes already installed inside the cleaner.
Metal Brushes for
Automatic Tip Cleaner …………………….. 2 units
Ref. CL1008
Fiber Brushes for
Ref. CL2008
Features and Connections
Keypad
- White: Off
- Blue: Standby
- Green : Brushes activated
- Blinking Red : Brushes jammed
Operation
For best cleaning results, we recommend placing the tip between the two
brushes for just 1 second. Longer exposure time would lead to dewetting of tip
surface causing oxidation.
If excessive pressure is applied with the tool against any of the brushes, the
cleaner stops automatically in order to protect the motors. Putting the tool
out of the sensor detection area automatically deactivates the cleaner.
The tip cleaner is automatically switched off if splashguard is opened during operation.
Set Up
CLMU/CLMUP allows you to choose between continuous operation and sensor
operation.
The tip cleaner contains a sensor that detects when the soldering cartridge
approaches the window and automatically starts the brush rotation.
You can choose between 3 different settings for sensor operation.
- Level 1 – for a short detection distance
- Level 2 – for a medium detection distance (default)
- Level 3 – for a long detection distance
Levels can be selected as follows:
- Turn on the tip cleaner by pressing the On / Off key.
- Push the “Sensor Mode” key until the interior light and keypad LEDs make one, two or three blinks. The number of blinks indicates the selected level.
- Push the sensor mode button to change to the next level. If the button is held down, the level changes continuously to the next one until the button is released (changes from level 1 to 2, from 2 to 3 and from 3 to 1).
The level configuration is saved by the tip cleaner and will not be changed after the device is restarted.
Changing Brushes
Before opening tip cleaner, unplug from the mains.
Open Splashguard
Pull the locking tab (1) to open the splashguard.
Removing Inserting Brushes
Press the brush buttons (2) to remove the brushes (3).
Align the brushes with the axis and push them in until a click is heard (4). Check if the brushes are properly fixed.
Cleaning Solder Collection Tray
The tip cleaner features a solder collection tray. After cleaning place it
back in its position (5).
Accessories: Brush Range
All brushes are offered with black and blue core, to distinguish them when working with lead-free and leaded solder.
Note: As a reference, the cleaning process should last around 1 second.
*Only use the non-metal brushes when they are rotating. Incorrect use will damage them.
USB Connector
Download the latest software from our website to improve your tip cleaner.
JBC Updater
www.jbctools.com/software.html
Update the tip cleaner software via USB connection:
JBC Manager
www.jbctools.com/manager.html Manage
and monitor as many stations as your PC can handle by using the JBC Manager.
You can export data to another PC.
Manager Settings
Change settings for a group of JBC stations at the same time.
Register Settings
Create graphs of the soldering process in real time with power and
temperature data.
Maintenance
Before carrying out maintenance or storage, always unplug the equipment from the mains.
- Use a damp cloth to clean the splashguard outside and inside.
- Check periodically that the sensors window is clean. Use a cotton bud with alcohol to clean it.
- Maintain the brushes and the solder collection tray clean.
- Brushes (Metal and Fiber Brushes ) can be cleaned by immersing them in isopropyl alcohol. They must be allowed to dry before use.
- Replace any defective or damaged piece. Use original JBC spare parts only.
Repairs should be performed only by a JBC authorized technical service.
Sensor Window
Safety
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
- Do not use the appliance for any purpose other than tip cleaning. It is not a tool stand.
- The AC Adapter power supply must be plugged into approved bases.
- Do not leave the appliance unattended when it is running.
- Remove power cord by holding the plug, not the wire.
- Avoid contact with moving parts.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid harm.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
- Utmost care must be taken with liquid tin waste which can cause burns.
- Be careful with the fumes produced when soldering.
Specifications
CLMU / CLMUP
Automatic Tip Cleaner with Metal/Fiber Brushes
Ref.: CLMU-A with metal brushes
Ref.: CLMU-PB with fiber brushes
AC Adapter:
- Input: 100-240 V, 5/60 Hz
- Output : DC 24 V, 2 A
ESD safe Connector
- Ambient Operating Temperature 10 to 40 ºC / 50 to 104 ºF 50 mm / 2.0 in
- Brush diameter 131 x 129 x 136 mm /
- Cleaner Unit Dimension 2100 g / 6.03 lb
- Total Net Weight 220 x 213 x 160 mm / 2320g
- Package Dimensions/Weight 8.70 x 5.35 x 4.96 in / 6.75 lb
Complies with CE standards. ESD safe.
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects,
including the replacement of defective parts and labor.
Warranty does not cover product wear or misuse. In order for the warranty to
be valid, equipment must be returned, postage paid, to the dealer where it was
purchased.
This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>