BEFORE YOU BEGIN

  • Always use a new 9V alkaline battery with an extended expiration date at least 3 years beyond the current date. Connect the battery to the clip and match the direction to the image inside of the battery cavity. Be sure not to pull on wires when disconnecting an old battery.
  •  This device is recommended for interior use only.
  • If the device is used in a manner not specified here, the protection provided by the device may be impaired.
  •  No part of this device may be replaced or repaired by anyone except the manufacturer.ZIRCON-Leak-Alert-Electronic-Water-Detector-fig-1

The Leak Alert™ electronic water detector is a self-contained, battery-powered unit designed to minimize water damage by alerting you to a potential water leak. Two external metal strips (the Sensing Contacts) each carry a mild electrical current. If both strips get wet–from a plumbing leak, a flood, or surrounding moisture condensing on the surface, the detector will activate and sound a 90 dB alarm. In the event of a flood, the detector will float on top of the water, and will continue to signal for up to 72 hours.

INSTALL BATTERY

  1.  Insert a coin as shown. Twist coin to release cover.
  2.  Connect a new alkaline 9V battery with an extended expiration date at least 3 years beyond the current date. Be sure not to pull on wires when disconnecting an old battery. ZIRCON-Leak-Alert-Electronic-Water-Detector-fig-3
  3. Position the battery as shown, as far into the cavity as possible. ZIRCON-Leak-Alert-Electronic-Water-Detector-fig-4
  4. Close cover securely.

TEST DETECTOR

Whenever you install a new battery, test the detector to ensure that it works properly.

  1.  Wet your fingers and touch both Sensing Contacts. ZIRCON-Leak-Alert-Electronic-Water-Detector-fig-5
  2.  A loud, repetitive beep will sound.
  3. To stop the alarm, wipe the Sensing Contacts with a clean, dry cloth.

POSITION THE DETECTOR

The Leak Alert™ electronic water detector can be used wherever there is a potential risk for flooding.

Common usage areas include sinks,
toilets, water heaters, washing machines, aquariums, or sump pumps. You can also use it in more general areas, such as basements or garages.

  1. Place the detector as shown (Figure E), with Sensing Contacts touching the floor.
  2. The detector will be unable to detect water if Contacts are up.
    NOTE : When possible, avoid placing the Leak Alert™ directly under potential leaking point (for example, directly under the toilet supply hose).
    Instead, the detector’s Sensing Contacts on the bottom of the unit should be able to come into contact with the water leakage.

IF FLOODING OCCURS

In the event that an area floods,
the detector will float, and the alarm will sound for the life of the battery, up to 72 hours.

LOW BATTERY WARNING

In the event of low battery, water detector will chirp (short beep every five seconds). Immediately replace the battery with a new 9V alkaline battery with a valid extended expiration date of at least 3 years beyond the current date.
REPLACE BATTERY AND RETEST UNIT ANNUALLY.

LIMITED LIFETIME WARRANTY

Zircon Corporation (“Zircon”) warrants to the original purchaser (or original user by gift) that this product will be free from defects in materials and workmanship for its useful life (not to exceed twenty years from date of purchase). This warranty is limited to the electronic circuitry of the product, and specifically excludes consumable parts, including batteries, and software, even if packaged with the product. Defects caused by abuse, modification, handling contrary to these instructions, other unreasonable use, or neglect are not covered under this warranty. No liability is accepted for normal wear and tear and minor defects which do not detract from the function of the product.

THIS LIMITED LIFETIME WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE, OR MALFUNCTION OF THIS PRODUCT. NO OTHER REPRESENTATIONS OR CLAIMS OF A SIMILAR NATURE WILL BIND OR OBLIGATE ZIRCON.

Some states do not allow limitations on certain implied warranties and/or the limitation on incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This Limited Lifetime Warranty applies only to products purchased within the United States of America (USA) and Canada. For warranty applicable to products purchased in all other geographical areas, see www.zircon.com/warranty. Any in-warranty defective product returned to Zircon, freight prepaid, along with dated purchase receipt and $10.00 to cover shipping and handling, will be repaired or replaced, at Zircon’s option. If the returned product is no longer available, Zircon may replace the product with a similar product of similar function. This is your sole and exclusive remedy for breach of this Limited Lifetime Warranty. To return product, call the Zircon Customer Service number below to request an RMA number and return product with shipment tracking to:

Zircon Corporation
Attn : Returns Department 1580 Dell Avenue Campbell, CA 95008-6992 USA
Include your name, return address,RMA number, and package tracking number. Allow 4 to 6 weeks for delivery. If you do not agree to the terms of this Limited Lifetime Warranty, you may not use this product and must promptly return it to the retailer, along with a dated purchase receipt within 30 days of purchase for a refund of the purchase price.

Customer Service : 1-800-245-9265 or 1-408-963-4550
Monday–Friday, 8:00 a.m.–5:00 p.m.
PST www.zircon.com[email protected]
©2021 Zircon Corporation P/N 58834
Rev I 08/21 Leak Alert and Zircon are trademarks or registered trademarks of Zircon Corporation.

TROUBLESHOOTING

SITUATION LIKELY CAUSE SOLUTION

__

__

__

False alarm sounds.

| Battery charge is low.| Change the battery.
Water detector is on a conductive surface, such as metal.| Place a thin piece of paper or plastic between detector and conductive surface.
Ambient moisture has collected on the Sensing Contacts.| Wipe Sensing Contacts dry.
__

Detector does not sound alarm even when touching water.

| Detector is positioned in a way that water does not touch Sensing Contacts.| Reposition the detector so Sensing Contacts are flat against the surface where water leakage might occur.
Battery is dead.| Install a new 9V alkaline battery with an extended expiration date.
Detector does not float.| Battery is not placed correctly in the battery cavity.| Position the battery per the battery installation instructions in this document.

Visit www.zircon.com for the most current instructions.

FCC Part 15 Class B Registration Warning:
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2.  this device must accept any interference received, including interference that may cause undesired operation.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ZIRCON User Manuals

Related Manuals