HotSpring 62982.23A Hot Springs Pools and Spas Instruction Manual

May 15, 2024
HOTSPRING

HotSpring logo HIGHLIFE® COLLECTION

62982.23A Hot Springs Pools and Spas

Congratulations on your decision to enjoy the finest spa available…
Welcome to the growing family of HOT SPRING spa owners.

Pre-Delivery Instructions

Please take the time to read this booklet carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation of your new spa. The following sections are guidelines on how to prepare for delivery and set-up of your new spa. Specifically covered are site selection, delivery access, ground preparation, and electrical requirements.
Remember to carefully review the Owner’s Manual that accompanies your spa, and to register the spa’s warranty within 10 days of delivery. These items, along with other valuable information, will be found in the Owner’s Package which has been placed in the equipment compartment of your spa, where you will also find its serial number.
Watkins Wellness™ reserves the right to change features, specifications and design without notification and without incurring any obligation.

DATE PURCHASED: …………………………………
DATE INSTALLED: ……………………………………
DEALER: ………………………………………………….
ADDRESS:………………………………………………..
TELEPHONE: ………………………………………….

Register your warranty using the QR code below:

http://smartyt.ag/fa8a0d

In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to a pool (or spa) by children under 5 years of age. Your HOT SPRING spa is equipped with a locking cover that meets the ASTM F134691 Standard for Safety Covers and as a result, is usually exempt from most barrier requirements. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit isobtained for the installation of an electrical circuit. Your Hot Spring dealer can provide information on which permitsmay be required.

Hot Spring Spa Pre-Delivery Instructions

Site Selection and Preparation
IMPORTANT: Site selection and preparation are your responsibility. Carefully read these instructions and consult your authorized HOT SPRING dealer if you have any questions.
You probably have a spot picked out for your new spa, whether it’s indoors or outdoors, on a patio or on a deck.
Just make sure you check the following:

  • Always put your spa on a structurally sound, level surface. A filled spa can weigh a great deal. Make certain that the location you choose can support the weight of your filled spa.
  • Locate your spa away from any reflective surface or glass. The heat generated by some types of doublepane windows and reflective surfaces can cause serious damage to the exterior of the spa, including the siding and cover.
  • Locate your equipment compartment, which houses all of the electrical components, in a place where water will drain away from it. Allowing water into the equipment compartment can damage the electronics, or may result in tripping your house’s circuit  breaker.
  • Leave yourself easy access to the circuit breakers in the subpanel (230 volt models), or to the interrupter switch on the end of the power cord (115 volt models).
  • Never let water get into the subpanel (230 volt models), into the interrupter switch (115 volt models), or into the electrical outlet that your spa is plugged into. Your 230 volt spa’s subpanel is raintight when installed correctly with the door closed.
  • Leave access to the equipment compartment for periodic spa care and maintenance.

OUTDOOR AND PATIO INSTALLATION
No matter where you install your new spa, it’s important that you have a solid foundation to support it. Structural damage to the spa resulting from incorrect installation or placement on an inadequate foundation is not covered under the spa’s limited warranty.
If you install the spa outdoors, a reinforced concrete pad at least four inches thick is required for the Grandee & Envoy® spas, and recommended for the Vanguard® , Aria® , Sovereign® , Prodigy® and Jetsetter spas. The reinforcing rod or mesh in the pad should be attached to a bond wire (see your Owner’s Manual). All Hot Spring spas may be installed onto a deck, provided that the load capacity of the deck is greater than the dead weight of the spa (see Deck Installation).
If you place the spa on the ground, even temporarily, place stepping stones under the leveling areas. The stones should be at least two inches thick and twelve inches square. Even with stones in place, the spa will inevitably settle and become unlevel. Plus, a spa surrounded by dirt or grass will soon be filled with dirt or grass from users’ feet; therefore, it is important to get it onto a solid foundation as soon as possible.
DECK INSTALLATION
To be certain your deck can support your spa, you must know the deck’s maximum load capacity. Consult a qualified building contractor or structural engineer before you place the spa on an elevated deck or indoors. To find the weight of your spa, its contents and occupants, refer to the Spa Specification chart. This weight per square foot must not exceed the structure’s rated capacity, or serious structural damage could result.
INDOOR INSTALLATION
Be aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so flooring materials must provide a good grip when wet. Proper drainage is essential to prevent a build-up of water around the spa. When building a new room for the spa, it is recommended that a floor drain be installed. The humidity will naturally increase with the spa installed. Water may get into woodwork and produce dryrot, mildew, or other problems. Check for airborne moisture’s effects on exposed wood, paper, etc. in the room. To minimize these effects, it is best to provide plenty of ventilation to the spa area. An architect can help to determine if more ventilation must be installed.
Your HOT SPRING dealer can help you with local information such as zoning regulations and building codes.

DELIVERY ACCESS

First, locate the dimensions of your spa on the following chart. The dimensions shown are the measurements of the spa in the vertical position, laid on its side.
Next, contact your dealer to find the height and width added by the delivery cart which the dealer will use to deliver your new spa. Use the height of the cart plus the dimension shown as H to determine the vertical clearance required to pass the spa and cart.
Use the width of the cart, or dimension W, whichever is greater, to determine the maximum width of clearance necessary. Use the length dimension L when making any sharp turns to determine the maximum clearance required.HotSpring
62982.23A Hot Springs Pools and Spas - DELIVERY ACCESS NOTE: It may be necessary to allow for additional over-head clearance if the spa will be rolled up or down an incline or moved up or down a short flight of stairs.
Use the information below to determine the requirements for access to your desired location.

Model Width W Length L Height H
GRANDEE (GGN) 38″ (97 cm) 100″ (2.54 m) 91″ (2.31 m)
ENVOY (KKN) 38″ (97 cm) 100″ (2.54 m) 91″ (2.31 m)
VANGUARD (VVN) 36″ (91 cm) 87″ (2.21 m) 87″ (2.21 m)
ARIA (ARN) 36″ (91 cm) 87″ (2.21 m) 87″ (2.21 m)
OVEREIGN (IIN) 33″ (84 cm) 93″ (2.36 m) 80″ (2.03 m)
PRODIGY (HN) 33″ (84 cm) 84″ (2.13 m) 78″ (1.98 m)
JETSETTER LX (JTN) 33″ (84 cm) 84″ (2.13 m) 68″ (1.73 m)
JETSETTER (JJN) 33″ (84 cm) 84″ (2.13 m) 68″ (1.73 m)

HotSpring 62982.23A Hot Springs Pools and Spas - DELIVERY ACCESS
1It may be necessary to remove a gate, part of a fence, or other movable obstructions in order to roll the spa to its installation site. About ten percent of the time, a crane is the only way to install the spa by lifting it to its final destination.
If the spa has to be taken off of the cart to go over a wall (either because the entry area is too narrow, the eaves are too low, the corner is too tight, or the stairway is too steep), a crane will be required. Don’t be alarmed! The crane has a truck-mounted boom which can fit right in your driveway. It is run by a licensed and insured operator. For a charge, the crane operator will lift your spa over walls, buildings, or any other obstruction and place it as close to the installation site as possible. The HOT SPRING spa delivery personnel will supervise the crane delivery and complete the spa installation.
NOTE: If your spa delivery requires the use of a crane, you may be required to pay for its services at the completion of the delivery.

GROUND PREPARATION

Your Hot Spring spa has been engineered to perform on several types of yard surfaces. While a concrete slab is recommended, other foundations (illustrated below) are acceptable so long as a level base is prepared prior to delivery.
NOTE: Have a reinforced concrete pad at least 4 inches (10cm) thick or a deck that is able to withstand the pounds per square foot listed in the Spa Specification section.

INSTALLATION NOTES:

  • Concrete sloped at 1/2 inch per 10 feet (1 cm per 3 m) is preferred so that rain water and water spillover will run off and not puddle underneath the spa.
  • If brick or wood decking is selected for the spa foundation, it should be placed and leveled below the entire spa to maintain even distribution of the spa weight.
  • It is important to note that if bricks are used to distribute the weight of the spa there may still be a tendency to settle unevenly, resulting in an unlevel spa.
  • Remember, placing the spa around grass or dirt may increase the amount of debris which is inadvertently brought into the spa water on the user’s feet.
    If you are purchasing a deck package or a gazebo with your spa, a solid foundation becomes mandatory. Placing them on any surface other than a single level pad could create problems with their installation. Pictured at right are the recommended surfaces.
    As a homeowner, it is your responsibility to provide a suitable, level foundation for your spa. Keep in mind that most delivery crews are not equipped to level and prepare spa sites.
    If you are interested in having a concrete slab, brick surface, or wood deck installed, your HOT SPRING dealer should be able to suggest a qualified, licensed contractor.
    NOTE: In order for the spa to operate properly and the internal plumbing to drain completely, you must ensure
    that the spa surface is leveled before the spa has been installed. Shimming or point leveling is NOT supported or
    recommended by the manufacturer.

HotSpring 62982.23A Hot Springs Pools and Spas - DELIVERY ACCESS
2

GRANDEE (GGN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions.
Configuration and location may change without notice.HotSpring 62982.23A Hot
Springs Pools and Spas - Dimensions

NOTE: WATKINS WELLNESS requires that the GRANDEE be installed on a minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able to withstand more than 125 lbs/ft² (605 kg/m²).
WARNING: The GRANDEE must not be shimmed in any manner.

ENVOY (KKN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions.
Configuration and location may change without notice.HotSpring 62982.23A Hot
Springs Pools and Spas - Dimensions 1

NOTE: WATKINS WELLNESS requires that the ENVOY be installed on a minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able to withstand more than 120 lbs/ft² (570 kg/m²).
WARNING: The ENVOY must not be shimmed in any manner.

VANGUARD (VVN) & ARIA (ARN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions.
Configuration and location may change without notice.HotSpring 62982.23A Hot
Springs Pools and Spas - Dimensions 2

NOTE: WATKINS WELLNESS recommends that the VANGUARD & ARIA be installed on a minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able to withstand more than 130 lbs/ft² (630 kg/m²) & 125 lbs/ft² (595 kg/m²).
WARNING: The VANGUARD & ARIA must not be shimmed in any manner.

SOVEREIGN (IIN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions.
Configuration and location may change without notice.HotSpring 62982.23A Hot
Springs Pools and Spas - Dimensions 3

NOTE: WATKINS WELLNESS recommends that the SOVEREIGN be installed on a minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able to withstand more than 115 lbs/ft² (555 kg/m²).
WARNING: The SOVEREIGN must not be shimmed in any manner.

PRODIGY (HN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions.
Configuration and location may change without notice.HotSpring 62982.23A
Hot Springs Pools and Spas - Dimensions 4 NOTE: WATKINS WELLNESS recommends that the PRODIGY be installed on a minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able to withstand more than 130 lbs/ft² (620 kg/m²).
WARNING: The PRODIGY must not be shimmed in any manner.

JETSETTER LX (JTN) & JETSETTER (JJN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions.
Configuration and location may change without notice.HotSpring 62982.23A Hot
Springs Pools and Spas - Dimensions 5

ELECTRICAL REQUIREMENTS

To ensure you will have an opportunity to use your spa soon after delivery, it is very important that the required electrical service has been installed. Unless otherwise stipulated by your dealer, THIS IS YOUR RESPONSIBILITY.
IMPORTANT: All electrical circuits must be installed by a qualified, licensed electrician.
HOT SPRING spas are manufactured in two different electrical versions. The GRANDEE, ENVOY, VANGUARD, ARIA, SOVEREIGN, PRODIGY and JETSETTER LX models are available with a 230 volt continuous heating system. These spas cannot be converted to 115 volt operation.
The remaining spa model, the JETSETTER is available as 115 volt or 230 volt convertible heating systems. This models comes standard from the factory with 115 volt heating systems; however, with the addition of a subpanel and a control box wiring change, it can be converted to 230 volt operation. See the following sections for the electrical requirements for 115 volt operation, 230 volt operation and 230 volt converted operation.
115 VOLT OPERATION REQUIREMENTS
The 115 volt spa requires a dedicated 20 amp, 115 volt circuit. This circuit must be properly wired; that is, it must have a 20 amp GFCI breaker in the main electrical service panel, and #12 AWG wire (including ground wire) and the correct polarity throughout the circuit.
WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maximum voltage drop of 3% be used when calculating the larger wire size.
NOTE: The term “dedicated” means that only the spa operates on the circuit.
The 115 volt model comes equipped with approximately 15 feet of usable power cord. (This is the maximum length allowed by Underwriters Laboratory.) When the spa is installed, the power cord will come out of the bottom of the equipment compartment.
In addition to the dedicated 20 amp, 115 volt GFCI protected circuit, your spa requires a 20 amp single receptacle.
This receptacle, which contains an outdoor-rated, weather-resistant receptacle cover plate, will be provided to you.
The single receptacle and cover plate should be installed by your electrician prior to the delivery of your spa.
For your safety, when your electrician is installing the electrical outlet, it should be no closer than five (5) feet and no farther than ten (10) feet from the spa. (Reference National Electric Code 680-6a(1) and 680-41a.)
WARNINGS: Do not connect your spa to an extension cord!
The 115 volt GFCI switch and the receptacle must be protected from weather and landscape sprinklers–they should never get wet.
NOTE: If you require the services of a licensed electrician, your HOT SPRING Dealer should be able to suggest one for you.
Your HOT SPRING spa has been carefully engineered to provide maximum safety against electric shock.
Remember, connecting the spa to an improperly wired circuit will negate many of its safety features.HotSpring 62982.23A Hot Springs Pools and Spas -
OPERATION REQUIREMENTS 230 VOLT OPERATION REQUIREMENTS
All models require a 50 amp, single phase, 230 volt circuit breaker in the main electrical service panel.
All 230 volt Hot Spring
spas must be wired in accordance with applicable local and national electrical codes, all electrical work must be done by a licensed electrician.
NOTE: WATKINS WELLNESS REQUIRES THE USE OF A SUBPANEL TO SUPPLY POWER AND PROTECT THE SPA. The subpanel containing GFCI breakers is included with the spa except for JETSETTER (JJN).
A licensed electrician should install a four-wire electrical service (two line voltages, one neutral, one ground) from the main electrical service panel to the subpanel, and from the sub-panel to the spa per the appropriate wiring diagram as illustrated below.
The grounding conductor must be at least #10 AWG. Your electrician should mount the subpanel in the vicinity of the spa but it should not be closer than 5 feet (1.5 m) from the spa water edge (NEC 680-38 to 41-A-3).
INSTALLATION NOTE: After the spa has been installed by the dealer’s delivery crew, your electrician can connect the conduit from the subpanel to the spa’s IQ 2020 Control Box and then complete the wiring connections in the control box.
IMPORTANT NOTE: Three different wiring diagrams are shown: one for GRANDEE, ENVOY, VANGUARD & ARIA models. One for the SOVEREIGN, PRODIGY & JETSETTER LX models, and one for the JETSETTER JJN model.
Always follow the wiring diagram for your specific model.
NOTE: Complete Installation and Wiring Instructions for all 230 volt Hot Spring models are included in the Owner’s Manual and with each sub-panel, which can be obtained from your dealer.
WARNING: Removing or bypassing the GFCI breakers in the subpanel at any time will result in an unsafe spa and will void the warranty.
WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maximum voltage drop of 3% be used when calculating the larger wire size.
Refer to the Wiring Diagrams to the right for the electrical requirements of the 230 volt models.
When connecting the supply conduit to the bottom of the IQ 2020 box, use the recommended connectors, page is attached to the control box inside the spa.

GRANDEE (GGN), ENVOY (KKN), VANGUARD (VVN) & ARIA (ARN) 230 volt permanently connected models

HotSpring 62982.23A Hot Springs Pools and Spas - OPERATION REQUIREMENTS
1HotSpring 62982.23A Hot
Springs Pools and Spas - OPERATION REQUIREMENTS 2![HotSpring 62982.23A Hot Springs Pools and Spas

  • OPERATION REQUIREMENTS 3](https://manuals.plus/wp- content/uploads/2024/03/HotSpring-62982.23A-Hot-Springs-Pools-and-Spas- OPERATION-REQUIREMENTS-3.jpg)* Refer to NEC 250-122 (table)
    NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker.
    AVAILABLE FROM DEALER. NOTE: ALL WIRING SHOULD BE COPPER.

WIRE INSTALLATION

FOR CONTROL BOX TERMINAL BLOCK (Layout of Spa’s Terminal Blocks may vary)
Wire Installation Steps
Refer to spa’s wiring diagram on back of Control Box Cover for proper wiring and jumper configuration!HotSpring 62982.23A Hot Springs Pools and Spas -
WIRE INSTALLATION ELECTRICAL ACCESS INTO SPA HotSpring 62982.23A Hot
Springs Pools and Spas - ELECTRICAL ACCESS INTO SPA

SERVICES AVAILABLE FROM YOUR HOT SPRING SPA DEALER

Service Cost
Pre-Delivery site inspection _____
Deliver spa to installation site _____
Unwrap spa and haul away packaging material _____
Set up & level spa _____
Install FreshWater® Salt System _____
Fill the spa with water _____
Explain and test the spa’s operation _____
  • Jet system
  • Set temperature control
  • Moto-Massage® DX jet
  • Control panel functions
  • Comfort Control® system

Explain the safety features

  • GFCI
  • Heater high limit
  • Heater thermal cut-off
Service Cost
General spa operation & maintenance orientation _____
Water quality and maintenance orientation _____
Adjust the water’s Total Alkalinity, and pH _____
Sanitize the water _____
Inspect the spa cover, place on spa _____
Review winterizing instructions _____
Review Owner’s Manual & Warranty Card _____
Follow-up call In-store spa water analysis _____
TOTAL COST _____

ADDITIONAL PRODUCTS AVAILABLE FROM YOUR HOT SPRING SPA DEALER

  • FRESHWATER® Salt System

  • FRESHWATER® III high output ozone, MPS, and FRESHWATER® Ag+ Silver Ion Cartridge (sold separately)

  • Clean Screen® Pre-filter

  • Vanishing Act® Calcium Remover

  • FRESHWATER® Spa Salt

  • FRESHWATER® Salt Test Strips

  • FRESHWATER® Salt System Replacement Cartridges

  • FRESHWATER® 5-way Test Strips

  • FRESHWATER® Bottled Water Care Products

  • FRESHWATER® Instant Filter Cleaner and Filter Cleaner

  • FRESHWATER® Spa Shine

  • FRESHWATER® CoverShield

  • Retractable cover systems including the CoverCradle® , CoverCradle II, UpRite and Lift’n Glide systems.
    • Cover Cradle – 24” (61 cm) Clearance required
    • Cover Cradle II – 24” (61 cm) Clearance required
    • UpRite – 7” (18 cm) Clearance required
    • Lift ’n Glide – 14” (36 cm) Clearance required

  • Vinyl covers

  • Spa steps

  • Replacement filter cartridges

  • Pillows

NOTE: Actual clearance may vary depending on spa model and installation location. Check with dealer for further details.

CONTRACTOR SUGGESTIONS
Electrician
Name: __
Telephone:

Name: ____
Telephone: _
Masonry
Name: ___

Telephone: _
Name: __
Telephone: _

General
Name: __
Telephone: ___
Name: __
Telephone: __

Spa Specifications

HotSpring 62982.23A Hot Springs Pools and Spas - TableHotSpring 62982.23A Hot Springs Pools and Spas - Table
1 CAUTION: WATKINS WELLNESS suggests a structural engineer or contractor be consulted before the spa is placed on an elevated deck.

  • NOTE: The “Filled weight” and “Dead weight” of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs [80 kg]).
    **Effective filter area is based on 6.5 square feet actual area per filter with 10 times effectivity rating.

©2023 WATKINS WELLNESS All Rights Reserved.
Hot Spring, Built for a lifetime of relaxation, Moto-Massage, Highlife, Grandee, Envoy, Vanguard, Aria, Sovereign, Prodigy, Jetsetter, AutoFresh, Comfort Control, CoverCradle, GlideRite, Lift’nGlide, UpRite, IQ 2020, CoverShield, FreshWater, Vanishing Act and The Home Relaxation Specialists are trademarks of WATKINS WELLNESS.

HotSpring logoHotSpring logo 11280 Park Center Drive
Vista, California 92081
(800) 999-4688 extension 8432
62982.23 A (2/23)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HOTSPRING User Manuals

Related Manuals