HotSpring 62982.23A Hot Springs Pools and Spas Instruction Manual
- May 15, 2024
- HOTSPRING
Table of Contents
HIGHLIFE® COLLECTION
62982.23A Hot Springs Pools and Spas
Congratulations on your decision to enjoy the finest spa available…
Welcome to the growing family of HOT SPRING spa owners.
Pre-Delivery Instructions
Please take the time to read this booklet carefully, as it will provide you
with the information you will need to ensure the safe, secure, and timely
installation of your new spa. The following sections are guidelines on how to
prepare for delivery and set-up of your new spa. Specifically covered are site
selection, delivery access, ground preparation, and electrical requirements.
Remember to carefully review the Owner’s Manual that accompanies your spa, and
to register the spa’s warranty within 10 days of delivery. These items, along
with other valuable information, will be found in the Owner’s Package which
has been placed in the equipment compartment of your spa, where you will also
find its serial number.
Watkins Wellness™ reserves the right to change features, specifications and
design without notification and without incurring any obligation.
DATE PURCHASED: …………………………………
DATE INSTALLED: ……………………………………
DEALER: ………………………………………………….
ADDRESS:………………………………………………..
TELEPHONE: ………………………………………….
Register your warranty using the QR code below:
In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to a pool (or spa) by children under 5 years of age. Your HOT SPRING spa is equipped with a locking cover that meets the ASTM F134691 Standard for Safety Covers and as a result, is usually exempt from most barrier requirements. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit isobtained for the installation of an electrical circuit. Your Hot Spring dealer can provide information on which permitsmay be required.
Hot Spring Spa Pre-Delivery Instructions
Site Selection and Preparation
IMPORTANT: Site selection and preparation are your responsibility.
Carefully read these instructions and consult your authorized HOT SPRING
dealer if you have any questions.
You probably have a spot picked out for your new spa, whether it’s indoors or
outdoors, on a patio or on a deck.
Just make sure you check the following:
- Always put your spa on a structurally sound, level surface. A filled spa can weigh a great deal. Make certain that the location you choose can support the weight of your filled spa.
- Locate your spa away from any reflective surface or glass. The heat generated by some types of doublepane windows and reflective surfaces can cause serious damage to the exterior of the spa, including the siding and cover.
- Locate your equipment compartment, which houses all of the electrical components, in a place where water will drain away from it. Allowing water into the equipment compartment can damage the electronics, or may result in tripping your house’s circuit breaker.
- Leave yourself easy access to the circuit breakers in the subpanel (230 volt models), or to the interrupter switch on the end of the power cord (115 volt models).
- Never let water get into the subpanel (230 volt models), into the interrupter switch (115 volt models), or into the electrical outlet that your spa is plugged into. Your 230 volt spa’s subpanel is raintight when installed correctly with the door closed.
- Leave access to the equipment compartment for periodic spa care and maintenance.
OUTDOOR AND PATIO INSTALLATION
No matter where you install your new spa, it’s important that you have a solid
foundation to support it. Structural damage to the spa resulting from
incorrect installation or placement on an inadequate foundation is not covered
under the spa’s limited warranty.
If you install the spa outdoors, a reinforced concrete pad at least four
inches thick is required for the Grandee & Envoy® spas, and recommended for
the Vanguard® , Aria® , Sovereign® , Prodigy® and Jetsetter spas. The
reinforcing rod or mesh in the pad should be attached to a bond wire (see your
Owner’s Manual). All Hot Spring spas may be installed onto a deck, provided
that the load capacity of the deck is greater than the dead weight of the spa
(see Deck Installation).
If you place the spa on the ground, even temporarily, place stepping stones
under the leveling areas. The stones should be at least two inches thick and
twelve inches square. Even with stones in place, the spa will inevitably
settle and become unlevel. Plus, a spa surrounded by dirt or grass will soon
be filled with dirt or grass from users’ feet; therefore, it is important to
get it onto a solid foundation as soon as possible.
DECK INSTALLATION
To be certain your deck can support your spa, you must know the deck’s maximum
load capacity. Consult a qualified building contractor or structural engineer
before you place the spa on an elevated deck or indoors. To find the weight of
your spa, its contents and occupants, refer to the Spa Specification chart.
This weight per square foot must not exceed the structure’s rated capacity, or
serious structural damage could result.
INDOOR INSTALLATION
Be aware of some special requirements if you place your spa indoors. Water
will accumulate around the spa, so flooring materials must provide a good grip
when wet. Proper drainage is essential to prevent a build-up of water around
the spa. When building a new room for the spa, it is recommended that a floor
drain be installed. The humidity will naturally increase with the spa
installed. Water may get into woodwork and produce dryrot, mildew, or other
problems. Check for airborne moisture’s effects on exposed wood, paper, etc.
in the room. To minimize these effects, it is best to provide plenty of
ventilation to the spa area. An architect can help to determine if more
ventilation must be installed.
Your HOT SPRING dealer can help you with local information such as zoning
regulations and building codes.
DELIVERY ACCESS
First, locate the dimensions of your spa on the following chart. The
dimensions shown are the measurements of the spa in the vertical position,
laid on its side.
Next, contact your dealer to find the height and width added by the delivery
cart which the dealer will use to deliver your new spa. Use the height of the
cart plus the dimension shown as H to determine the vertical clearance
required to pass the spa and cart.
Use the width of the cart, or dimension W, whichever is greater, to determine
the maximum width of clearance necessary. Use the length dimension L when
making any sharp turns to determine the maximum clearance required. NOTE: It may be necessary to allow for additional
over-head clearance if the spa will be rolled up or down an incline or moved
up or down a short flight of stairs.
Use the information below to determine the requirements for access to your
desired location.
Model | Width W | Length L | Height H |
---|---|---|---|
GRANDEE (GGN) | 38″ (97 cm) | 100″ (2.54 m) | 91″ (2.31 m) |
ENVOY (KKN) | 38″ (97 cm) | 100″ (2.54 m) | 91″ (2.31 m) |
VANGUARD (VVN) | 36″ (91 cm) | 87″ (2.21 m) | 87″ (2.21 m) |
ARIA (ARN) | 36″ (91 cm) | 87″ (2.21 m) | 87″ (2.21 m) |
OVEREIGN (IIN) | 33″ (84 cm) | 93″ (2.36 m) | 80″ (2.03 m) |
PRODIGY (HN) | 33″ (84 cm) | 84″ (2.13 m) | 78″ (1.98 m) |
JETSETTER LX (JTN) | 33″ (84 cm) | 84″ (2.13 m) | 68″ (1.73 m) |
JETSETTER (JJN) | 33″ (84 cm) | 84″ (2.13 m) | 68″ (1.73 m) |
It may be necessary to remove a
gate, part of a fence, or other movable obstructions in order to roll the spa
to its installation site. About ten percent of the time, a crane is the only
way to install the spa by lifting it to its final destination.
If the spa has to be taken off of the cart to go over a wall (either because
the entry area is too narrow, the eaves are too low, the corner is too tight,
or the stairway is too steep), a crane will be required. Don’t be alarmed! The
crane has a truck-mounted boom which can fit right in your driveway. It is run
by a licensed and insured operator. For a charge, the crane operator will lift
your spa over walls, buildings, or any other obstruction and place it as close
to the installation site as possible. The HOT SPRING spa delivery personnel
will supervise the crane delivery and complete the spa installation.
NOTE: If your spa delivery requires the use of a crane, you may be
required to pay for its services at the completion of the delivery.
GROUND PREPARATION
Your Hot Spring spa has been engineered to perform on several types of yard
surfaces. While a concrete slab is recommended, other foundations (illustrated
below) are acceptable so long as a level base is prepared prior to delivery.
NOTE: Have a reinforced concrete pad at least 4 inches (10cm) thick or a
deck that is able to withstand the pounds per square foot listed in the Spa
Specification section.
INSTALLATION NOTES:
- Concrete sloped at 1/2 inch per 10 feet (1 cm per 3 m) is preferred so that rain water and water spillover will run off and not puddle underneath the spa.
- If brick or wood decking is selected for the spa foundation, it should be placed and leveled below the entire spa to maintain even distribution of the spa weight.
- It is important to note that if bricks are used to distribute the weight of the spa there may still be a tendency to settle unevenly, resulting in an unlevel spa.
- Remember, placing the spa around grass or dirt may increase the amount of debris which is inadvertently brought into the spa water on the user’s feet.
If you are purchasing a deck package or a gazebo with your spa, a solid foundation becomes mandatory. Placing them on any surface other than a single level pad could create problems with their installation. Pictured at right are the recommended surfaces.
As a homeowner, it is your responsibility to provide a suitable, level foundation for your spa. Keep in mind that most delivery crews are not equipped to level and prepare spa sites.
If you are interested in having a concrete slab, brick surface, or wood deck installed, your HOT SPRING dealer should be able to suggest a qualified, licensed contractor.
NOTE: In order for the spa to operate properly and the internal plumbing to drain completely, you must ensure
that the spa surface is leveled before the spa has been installed. Shimming or point leveling is NOT supported or
recommended by the manufacturer.
GRANDEE (GGN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making
critical design or pathway decisions.
Configuration and location may change without notice.
NOTE: WATKINS WELLNESS requires that the GRANDEE be installed on a
minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able to
withstand more than 125 lbs/ft² (605 kg/m²).
WARNING: The GRANDEE must not be shimmed in any manner.
ENVOY (KKN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making
critical design or pathway decisions.
Configuration and location may change without notice.
NOTE: WATKINS WELLNESS requires that the ENVOY be installed on a minimum
4” (10 cm) thick reinforced concrete pad or a deck that is able to withstand
more than 120 lbs/ft² (570 kg/m²).
WARNING: The ENVOY must not be shimmed in any manner.
VANGUARD (VVN) & ARIA (ARN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making
critical design or pathway decisions.
Configuration and location may change without notice.
NOTE: WATKINS WELLNESS recommends that the VANGUARD & ARIA be installed
on a minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able
to withstand more than 130 lbs/ft² (630 kg/m²) & 125 lbs/ft² (595 kg/m²).
WARNING: The VANGUARD & ARIA must not be shimmed in any manner.
SOVEREIGN (IIN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making
critical design or pathway decisions.
Configuration and location may change without notice.
NOTE: WATKINS WELLNESS recommends that the SOVEREIGN be installed on a
minimum 4” (10 cm) thick reinforced concrete pad or a deck that is able to
withstand more than 115 lbs/ft² (555 kg/m²).
WARNING: The SOVEREIGN must not be shimmed in any manner.
PRODIGY (HN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making
critical design or pathway decisions.
Configuration and location may change without notice. NOTE: WATKINS WELLNESS recommends that the PRODIGY be
installed on a minimum 4” (10 cm) thick reinforced concrete pad or a deck that
is able to withstand more than 130 lbs/ft² (620 kg/m²).
WARNING: The PRODIGY must not be shimmed in any manner.
JETSETTER LX (JTN) & JETSETTER (JJN)
Dimensions
NOTE: All dimensions are approximate; measure your spa before making
critical design or pathway decisions.
Configuration and location may change without notice.
ELECTRICAL REQUIREMENTS
To ensure you will have an opportunity to use your spa soon after delivery, it
is very important that the required electrical service has been installed.
Unless otherwise stipulated by your dealer, THIS IS YOUR RESPONSIBILITY.
IMPORTANT: All electrical circuits must be installed by a qualified, licensed
electrician.
HOT SPRING spas are manufactured in two different electrical versions. The
GRANDEE, ENVOY, VANGUARD, ARIA, SOVEREIGN, PRODIGY and JETSETTER LX models are
available with a 230 volt continuous heating system. These spas cannot be
converted to 115 volt operation.
The remaining spa model, the JETSETTER is available as 115 volt or 230 volt
convertible heating systems. This models comes standard from the factory with
115 volt heating systems; however, with the addition of a subpanel and a
control box wiring change, it can be converted to 230 volt operation. See the
following sections for the electrical requirements for 115 volt operation, 230
volt operation and 230 volt converted operation.
115 VOLT OPERATION REQUIREMENTS
The 115 volt spa requires a dedicated 20 amp, 115 volt circuit. This circuit
must be properly wired; that is, it must have a 20 amp GFCI breaker in the
main electrical service panel, and #12 AWG wire (including ground wire) and
the correct polarity throughout the circuit.
WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed
wire than stated. We recommend that a maximum voltage drop of 3% be used when
calculating the larger wire size.
NOTE: The term “dedicated” means that only the spa operates on the
circuit.
The 115 volt model comes equipped with approximately 15 feet of usable power
cord. (This is the maximum length allowed by Underwriters Laboratory.) When
the spa is installed, the power cord will come out of the bottom of the
equipment compartment.
In addition to the dedicated 20 amp, 115 volt GFCI protected circuit, your spa
requires a 20 amp single receptacle.
This receptacle, which contains an outdoor-rated, weather-resistant receptacle
cover plate, will be provided to you.
The single receptacle and cover plate should be installed by your electrician
prior to the delivery of your spa.
For your safety, when your electrician is installing the electrical outlet, it
should be no closer than five (5) feet and no farther than ten (10) feet from
the spa. (Reference National Electric Code 680-6a(1) and 680-41a.)
WARNINGS: Do not connect your spa to an extension cord!
The 115 volt GFCI switch and the receptacle must be protected from weather and
landscape sprinklers–they should never get wet.
NOTE: If you require the services of a licensed electrician, your HOT
SPRING Dealer should be able to suggest one for you.
Your HOT SPRING spa has been carefully engineered to provide maximum safety
against electric shock.
Remember, connecting the spa to an improperly wired circuit will negate many
of its safety features. 230 VOLT OPERATION REQUIREMENTS
All models require a 50 amp, single phase, 230 volt circuit breaker in the
main electrical service panel.
All 230 volt Hot Spring
spas must be wired in accordance with applicable local and national electrical
codes, all electrical work must be done by a licensed electrician.
NOTE: WATKINS WELLNESS REQUIRES THE USE OF A SUBPANEL TO SUPPLY POWER AND
PROTECT THE SPA. The subpanel containing GFCI breakers is included with the
spa except for JETSETTER (JJN).
A licensed electrician should install a four-wire electrical service (two line
voltages, one neutral, one ground) from the main electrical service panel to
the subpanel, and from the sub-panel to the spa per the appropriate wiring
diagram as illustrated below.
The grounding conductor must be at least #10 AWG. Your electrician should
mount the subpanel in the vicinity of the spa but it should not be closer than
5 feet (1.5 m) from the spa water edge (NEC 680-38 to 41-A-3).
INSTALLATION NOTE: After the spa has been installed by the dealer’s
delivery crew, your electrician can connect the conduit from the subpanel to
the spa’s IQ 2020 Control Box and then complete the wiring connections in the
control box.
IMPORTANT NOTE: Three different wiring diagrams are shown: one for
GRANDEE, ENVOY, VANGUARD & ARIA models. One for the SOVEREIGN, PRODIGY &
JETSETTER LX models, and one for the JETSETTER JJN model.
Always follow the wiring diagram for your specific model.
NOTE: Complete Installation and Wiring Instructions for all 230 volt Hot
Spring models are included in the Owner’s Manual and with each sub-panel,
which can be obtained from your dealer.
WARNING: Removing or bypassing the GFCI breakers in the subpanel at any
time will result in an unsafe spa and will void the warranty.
WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge
feed wire than stated. We recommend that a maximum voltage drop of 3% be used
when calculating the larger wire size.
Refer to the Wiring Diagrams to the right for the electrical requirements of
the 230 volt models.
When connecting the supply conduit to the bottom of the IQ 2020 box, use the
recommended connectors, page is attached to the control box inside the spa.
GRANDEE (GGN), ENVOY (KKN), VANGUARD (VVN) & ARIA (ARN) 230 volt permanently connected models
![HotSpring 62982.23A Hot Springs Pools and Spas
- OPERATION REQUIREMENTS 3](https://manuals.plus/wp-
content/uploads/2024/03/HotSpring-62982.23A-Hot-Springs-Pools-and-Spas-
OPERATION-REQUIREMENTS-3.jpg)* Refer to NEC 250-122 (table)
NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker.
AVAILABLE FROM DEALER. NOTE: ALL WIRING SHOULD BE COPPER.
WIRE INSTALLATION
FOR CONTROL BOX TERMINAL BLOCK (Layout of Spa’s Terminal Blocks may vary)
Wire Installation Steps
Refer to spa’s wiring diagram on back of Control Box Cover for proper wiring
and jumper configuration! ELECTRICAL ACCESS INTO SPA
SERVICES AVAILABLE FROM YOUR HOT SPRING SPA DEALER
Service | Cost |
---|---|
Pre-Delivery site inspection | _____ |
Deliver spa to installation site | _____ |
Unwrap spa and haul away packaging material | _____ |
Set up & level spa | _____ |
Install FreshWater® Salt System | _____ |
Fill the spa with water | _____ |
Explain and test the spa’s operation | _____ |
- Jet system
- Set temperature control
- Moto-Massage® DX jet
- Control panel functions
- Comfort Control® system
Explain the safety features
- GFCI
- Heater high limit
- Heater thermal cut-off
Service | Cost |
---|---|
General spa operation & maintenance orientation | _____ |
Water quality and maintenance orientation | _____ |
Adjust the water’s Total Alkalinity, and pH | _____ |
Sanitize the water | _____ |
Inspect the spa cover, place on spa | _____ |
Review winterizing instructions | _____ |
Review Owner’s Manual & Warranty Card | _____ |
Follow-up call In-store spa water analysis | _____ |
TOTAL COST | _____ |
ADDITIONAL PRODUCTS AVAILABLE FROM YOUR HOT SPRING SPA DEALER
-
FRESHWATER® Salt System
-
FRESHWATER® III high output ozone, MPS, and FRESHWATER® Ag+ Silver Ion Cartridge (sold separately)
-
Clean Screen® Pre-filter
-
Vanishing Act® Calcium Remover
-
FRESHWATER® Spa Salt
-
FRESHWATER® Salt Test Strips
-
FRESHWATER® Salt System Replacement Cartridges
-
FRESHWATER® 5-way Test Strips
-
FRESHWATER® Bottled Water Care Products
-
FRESHWATER® Instant Filter Cleaner and Filter Cleaner
-
FRESHWATER® Spa Shine
-
FRESHWATER® CoverShield
-
Retractable cover systems including the CoverCradle® , CoverCradle II, UpRite and Lift’n Glide systems.
• Cover Cradle – 24” (61 cm) Clearance required
• Cover Cradle II – 24” (61 cm) Clearance required
• UpRite – 7” (18 cm) Clearance required
• Lift ’n Glide – 14” (36 cm) Clearance required -
Vinyl covers
-
Spa steps
-
Replacement filter cartridges
-
Pillows
NOTE: Actual clearance may vary depending on spa model and installation location. Check with dealer for further details.
CONTRACTOR SUGGESTIONS
Electrician
Name: __
Telephone:
Name: ____
Telephone: _
Masonry
Name: ___
Telephone: _
Name: __
Telephone: _
General
Name: __
Telephone: ___
Name: __
Telephone: __
Spa Specifications
CAUTION: WATKINS WELLNESS suggests a structural engineer or contractor be consulted before the spa is placed on an elevated deck.
- NOTE: The “Filled weight” and “Dead weight” of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs [80 kg]).
**Effective filter area is based on 6.5 square feet actual area per filter with 10 times effectivity rating.
©2023 WATKINS WELLNESS All Rights Reserved.
Hot Spring, Built for a lifetime of relaxation, Moto-Massage, Highlife,
Grandee, Envoy, Vanguard, Aria, Sovereign, Prodigy, Jetsetter, AutoFresh,
Comfort Control, CoverCradle, GlideRite, Lift’nGlide, UpRite, IQ 2020,
CoverShield, FreshWater, Vanishing Act and The Home Relaxation Specialists are
trademarks of WATKINS WELLNESS.
1280 Park Center Drive
Vista, California 92081
(800) 999-4688 extension 8432
62982.23 A (2/23)