AIPHONE AC-2DM AC Series Two Door Controller Instruction Manual
- June 13, 2024
- AIPHONE
Table of Contents
AIPHONE AC-2DM AC Series Two Door Controller
Product Information
The Motion Sensor is a device used for detecting motion in a specific area. It has the following specifications:
- Sensor Type: Motion Detection
- Detection Range: 5.8 meters (228.35 inches)
- Detection Angle: 2.2 meters (86.61 inches)
- Detection Zone: Not specified
The Motion Sensor requires specific cables for proper installation and operation. The cable requirements are as follows:
Cable Name | Maximum Distance | Cable Type |
---|---|---|
Network Cable*** | 100 meters (328 feet) | Twisted pair, 4 pairs, Cat5 100BASE-T |
or better
Reader Cable| 18 AWG: 152 meters (500 feet)
22 AWG: 76.2 meters (250 feet)**| 6 conductor stranded not twisted, 22 AWG
or thicker, 100%
overall shielded
Door Strike Cable| 152 meters (500 feet)| 2 conductor stranded 18 AWG
Output Cable| 152 meters (500 feet)| 2 conductor stranded 22 AWG
Input Cable| 152 meters (500 feet)| 2 conductor stranded 22 AWG, shielded
RS-485 Cable with Power| 600 meters (2000 feet)| 4 conductor stranded, twisted
pair, Belden 9402 2 pairs, 22 ~
16 AWG, shielded or equivalent*
Unless otherwise specified by the manufacturer.
Varies by current consumption of the other side.
Recommended T568B wiring for both ends.
Max distance may vary depending on cable gauge, environmental conditions, and
reader model.
Product Usage Instructions
To use the Motion Sensor, please follow these steps:
- Ensure that the Motion Sensor is properly installed and connected to the required cables as specified in the user manual.
- Power on the Motion Sensor by connecting it to a compatible power source.
- Adjust the detection range and angle of the Motion Sensor according to your specific needs. Refer to the user manual for instructions on how to adjust these settings.
- Once the Motion Sensor is powered on and properly configured, it will start detecting motion in its detection zone.
- The Motion Sensor can be integrated with other devices such as readers, door contacts, auto door openers, etc. Refer to the user manual for instructions on how to connect and configure these additional devices.
- Monitor the Motion Sensor for any motion detection alerts or triggers. Depending on the integration and configuration, the Motion Sensor can activate various outputs or inputs.
- Adjust or reconfigure the Motion Sensor settings as needed to optimize its performance and functionality.
- If you encounter any issues or need further assistance, refer to the troubleshooting section of the user manual or contact the manufacturer’s customer support.
For more detailed information on the product, including advanced configurations and features, please refer to the complete user manual available on the manufacturer’s website: www.aiphone.com.
PACKAGE CONTANTS
Installation Example
Networking Examples
UL 294 / S319 Compliance Notices
This product complies with the following UL294 Access Control Performance Levels when installed as part of the Listed AC-NIO system :
Endurance Level IV (100,000c) Line Security Level I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Part I, local codes, and the authorities having jurisdiction. All interconnecting devices must be UL Listed, low-voltage Class 2 power limited. The minimum permissible wire size to be used shall not be less than 26 AWG (0.24 mm2).
Products have been evaluated for “Indoor Use” only, and to be installed within the “protected” or “restricted” area. This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70. Products are not intended to be installed or mounted in air handling spaces. Products are intended to be installed by manufacturer-trained service installers only. All recommended connected peripherals such as power supplies, UPS/battery backups, PoE switches, electrified strikes, readers are required to be UL Listed. Please refer to the AC-NIO UL Reference document for more comprehensive information available via the installation USB drive or downloadable from our website. Hard copy of the AC-NIO UL Reference Manual document is available – call for pricing.
Readers & **Usage Example**
Wiring Specification
Ground | Black and shield wires 0 |
---|---|
Power (12V DC) | Red wire @ |
LED | Brown wire @ |
Buzzer | Blue wire 0 |
Data 1 | White wire 0 |
Data 0 | Green wire 0 |
Note : Reader Test
- 1 Get in Setup Menu Edit Mode by pressing Enter Key and hold.
- 2 Select Reader Test menu. (+ + Enter keys )
- Scan a card or press numbers and # (keypad reader only ). LCD shows the data infomation.
Outputs & **Usage Example**
Specification
P1 (Relay1, Lock power)| Lock power relay 0 , GND, @ 12V DC
500mA
---|---
PB (12V DC out)| 12V DC output, 0 GND, @ 12V DC 200mA
P6 (Relay2)| 24V DC 1A limit
P7 (Relay3)| 24V DC 1A limit
All the relay outputs are configurable.
For example, Relay2 can be configured to a door strike.
Note : Output Test
- Get in Setup Menu Edit Mode by pressing Enter Key and holding it.
- ( Select Output Test menu. († ≤ Enter keys )
- ® Toggle selected relay by pressing Enter. ( Select change : * – keys, 0 = Off, 1 = On )
Inputs & Usage Example
Specification
P2 1-2 Pin (lnput1) | Olnput | @Common | (GND) | |
---|---|---|---|---|
P2 2-3 Pin (lnput2) | @Common | (GND) | @Input | |
P3 1-2 Pin (lnput3) | Olnput | @Common | (GND) | |
P3 2-3 Pin (lnput4) | @Common | (GND) | @Input |
Note : Input Test
- Get in Setup Menu Edit Mode by pressing the Enter Key and holding it.
- Select Input Test menu.
- Enter keys ) © LCD displays current input states.
- D = Digital, S = Supervised,
- O = Open, C = Closed )
Input Types
Specification
-
Digital
Off(DO). On(DC) -
Supervised
Off(SO). On(SC). Short(DC). No connection(DO)
Software selectable
Dimensions
Board I/0 and Connections
LEDs
01 | System heart beat |
---|---|
02 | Server log on/off state Key pressed |
03 | On: Server log off Blink: Server log in |
04 | Green: Motion detected Red: Door Opened |
05 | Relay2 on |
06 | Relay3 on |
07 | Relay1 on |
08 | Reader1 data flow |
09 | Reader2 data flow |
017 | POE power |
024 | CPU power |
LINK | Ethernet linked |
ACT | Ethernet Activity |
Connectors
P1 | Relay1. DC 12V wet contact |
---|---|
P2 | lnput1. Common, lnput2 |
P3 | lnput3, Common, lnput4 |
P4 | Reader1 |
P5 | Reader2 |
P6 | Relay2 |
P7 | Relay3 |
PB | DC 12Vout |
P11 | Sensor module |
P21 | Expansion |
P22 | Expansion |
J1 | Ethernet |
Keys
SW1 | Left(+-). down(.J, ) |
---|---|
SW2 | Right( ), up(f- ) |
SW3 | Enter, get in |
SW4 | Esc, exit |
Etc
LS1 | Tamper sensor |
---|---|
S1 | Motion sensor |
BZ1 | Embedded buzzer |
P20 | LCD display |
VR1 | LCD contrast |
Setup Menu Edit Mode
Get in | Press and hold Enter (beeps after 2 sec) Enter password** |
---|---|
Toggle cursor | Enter |
White blink: move Black blink: edit
Get out| Esc
Move cursor| Up(Right),Down(Left)
Select menu| Enter
Exit menu| Esc
Setup Menu View Mode
Get in | Press and hold Esc (beeps after 2 sec) |
---|---|
Get out | Esc |
Move cursor | Up(Right),Down(Left) |
Select menu | Enter |
Exit menu | Esc |
Note
For a first-time installation, use this mode to do the following tests.
- Output Test: Toggle relays with Enter
- Input Test: Shows input states
- Reader Test: Shows scanned card info
- The factory default password is 0000.
- Toll Free: 1-800-692-0200
Motion Sensor
Specification Cable Requirements
Name
| Maximum Distance|
Cable Type
|
Code
---|---|---|---
Network Cable***| 100 m (328′)| twisted pair, 4 pairs| Cat5 100BASE-T or
better
Reader Cable| 18 AWG: 152 m
(500′)
22 AWG: 76.2 m
(250′)****
|
6 conductor stranded not twisted, 22 AWG or thicker,
100% overall shielded
|
Belden 5304FE or equivalent
Door Strike Cable| 152 m (500′)| 2 conductor stranded 18 AWG| Aiphone 821802
or equivalent
Output Cable| 152 m (500′)| 2 conductor stranded 22 AWG| Aiphone 822202 or
equivalent
Input Cable| 152 m (500′)| 2 conductor stranded 22 AWG, shielded| Aiphone
822202 or equivalent*
RS-485 Cable with Power| 600 m (2000′)| 4 conductor stranded, twisted pair, 2
pairs, 22 ~ 16 AWG*, shielded| Belden 9402 or equivalent
- Unless otherwise specified by
- Varies by current consumption of the other side.
- RecommendedT T568B wiring for both ends.
- Max distance may vary depending on cable gauge, environmental conditions and reader model.
- White/Orange
- Orange
- White/Green
- Blue
- White/Blue
- Green
- White/Brown
- Brown
Two Door Typical
(with motion, two readers, two door contacts, auto door opener)