GYS MULTICOOL 500, 1300 Arc Welding Battery Chargers and Body Repair User Guide
- June 4, 2024
- GYS
Table of Contents
- GYS MULTI COOL 500, 1300 Arc Welding Battery Chargers and Body Repair
- GENERAL INSTRUCTIONS
- RECOMMENDATIONS TO ASSES THE AREA AND WELDING INSTALLATION
- INSTALLATION
- MAINTENANCE / RECOMMENDATIONS
- INSTALLATION PRODUCT OPERATION
- EQUIPMENT DESCRIPTION
- STARTUP
- INITIATING THE COOLANT CIRCULATION
- SPARE PARTS
- TECHNICAL SPECIFICATIONS
- WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GYS MULTI COOL 500, 1300 Arc Welding Battery Chargers and Body Repair
GENERAL INSTRUCTIONS
Read and understand the following safety recommendations before using or
servicing the unit. Any change or servicing that is not specified in the
instruction manual must not be undertaken.
The manufacturer is not liable for any injury or damage caused due to non-
compliance with the instructions featured in this manual. In the event of
problems or uncertainties, please consult a qualified person to handle the
installation properly.
ENVIRONMENT
This equipment must only be used for welding operations in accordance with the limits indicated on the descriptive panel and/or in the user manual. The operator must respect the safety precautions that apply to this type of welding. In case of inadequate or unsafe use, the manufacturer cannot be held liable for damage or injury. This equipment must be used and stored in a place protected from dust, acid or any other corrosive agent. Operate the machine in an open, or well-ventilated area.
- Operating temperature: Use between -10 and +40°C (+14 and +104°F).
- Store between -20 and +55°C (-4 and 131°F).
- Air humidity: Lower or equal to 50% at 40°C (104°F).
- Lower or equal to 90% at 20°C (68°F).
- Altitude: Up to 1000 meters above sea level (3280 feet).
PROTECTION OF THE INDIVIDUALS
Arc welding can be dangerous and can cause serious injury or even death. Welding exposes the user to dangerous heat, arc rays, electromagnetic fields, the risk of electric shock, noise, and gas fumes. People wearing pacemakers are advised to consult a doctor before using the welding machine. To protect oneself as well as others, ensure the following safety precautions are taken:
- In order to protect you from burns and radiation, wear clothing without turn-ups or cuffs. These clothes must be insulating, dry, fireproof, in good condition, and cover the whole body.
- Wear protective gloves which guarantee electrical and thermal insulation.
- Use sufficient welding protective gear for the whole body: hood, gloves, jacket, trousers… (varies depending on the application/ operation). Protect the eyes during cleaning operations. Contact lenses are prohibited during use. It may be necessary to install fireproof welding curtains to protect the area against arc rays, weld spatter, and sparks. Inform the people around the working area to never look at the arc or the molten metal, and to wear protective clothing.
- Ensure ear protection is worn by the operator if the work exceeds the authorized noise limit (the same applies to any person in the welding area).
- Keep hands, hair and clothes away from moving parts such as fans, and engines. Never remove the safety covers from the cooling unit when the machine is plugged in. The manufacturer is not liable for any injury or damage caused due to non-compliance with the safety precautions.
- Parts that have just been welded will be hot and may cause burns when touched. When servicing the torch or electrode holder, make sure that it is cold enough by waiting at least 10 minutes before doing so. When using a water-cooled torch, make sure that the cooling unit is switched on to avoid any burns that could potentially be caused by the liquid. It is important to secure the working area before leaving it to ensure the protection of the goods and the safety of people.
WELDING FUMES AND GAS
The fumes, gases and dust produced during welding are hazardous. It is
mandatory to ensure adequate ventilation and/or extraction to keep fumes and
gases away from the work area. An air-fed helmet is recommended in cases of
insufficient air supply in the workplace. Check that the air intake is in
compliance with safety standards.
Care must be taken when welding in small areas, and the operator will need
supervision from a safe distance. Welding certain pieces of metal containing
lead, cadmium, zinc, mercury or beryllium can be extremely toxic. The user
will also need to degrease the workpiece before welding. Gas cylinders must be
stored in an open or ventilated area. The cylinders must be in a vertical
position secured to support or trolley. Do not weld in areas where grease or
paint are stored
FIRE AND EXPLOSION RISKS
Protect the entire welding area. Compressed gas containers and other
inflammable material must be moved to a minimum safe distance of 11 meters. A
fire extinguisher must be readily available. Be careful of spatter and sparks,
even through cracks. It can be the source of a fire or an explosion.
Keep people, flammable objects, and containers under pressure at a safe
distance. Welding of sealed containers or closed pipes should not be
undertaken, and if opened, the operator must remove any inflammable or
explosive materials (oil, petrol, gas…). Grinding operations should not be
directed towards the device itself, the power supply or any flammable
materials.
ELECTRIC SAFETY
The machine must be connected to an earthed electrical supply. Use the
recommended fuse size. An electrical discharge can directly or indirectly
cause serious or deadly accidents.
Do not touch any live part of the machine (inside or outside) when it is
plugged in (Torches, earth cable, cables, electrodes) because they are
connected to the welding circuit. Before opening the device, it is imperative
to disconnect it from the mains and wait 2 minutes, so that all the capacitors
are discharged. Do not touch the torch or electrode holder and earth clamp at
the same time. Damaged cables and torches must be changed by a qualified and
skilled professional. Make sure that the cable cross-section is adequate with
the usage (extensions and welding cables). Always wear dry clothes in good
condition, in order to be insulated from the electrical circuit. Wear
insulating shoes, regardless of the environment in which you work in.
CLASSIFICATION
This equipment is Class B. This equipment complies with the IEC 61000-3-12 standard. This equipment complies with the IEC 61000-3-11 standard.
RECOMMENDATIONS TO ASSES THE AREA AND WELDING INSTALLATION
Overview
The user is responsible for installing and using the arc welding equipment in accordance with the manufacturer’s instructions. If electromagnetic disturbances are detected, it is the responsibility of the user of the arc welding equipment to resolve the situation with the manufacturer’s technical assistance. In some cases, this remedial action may be as simple as earthing the welding circuit. In other cases, it may be necessary to construct an electromagnetic shield around the welding power source and around the entire piece by fitting input filters. In all cases, electromagnetic interferences must be reduced until they are no longer bothersome.
Welding area assessment
Ce Before installing the machine, the user must evaluate the possible
electromagnetic problems that may arise in the area where the installation is
planned.
In particular, it should consider the following:
- the presence of other power cables (power supply cables, telephone cables, command cables, etc…)above, below, and on the sides of the arc welding machine.
- television transmitters and receivers
- computers and other hardware;
- critical safety equipment such as industrial machine protections;
- the health and safety of the people in the area such as people with pacemakers or hearing aids;
- calibration and measuring equipment
- The isolation of the equipment from other machinery. The user will have to make sure that the devices and equipment that are in the same room are compatible with each other. This may require extra precautions;
- make sure of the exact hour when the welding and/or other operations will take place.
The surface of the area to be considered around the device depends on the building’s structure and other activities that take place there. The area taken in consideration can be larger than the limits determined by the companies.
Welding area assessment
Besides the welding area, the assessment of the arc welding systems installation itself can be used to identify and resolve cases of disturbances. The assessment of emissions must include in situ measurements as specified in Article 10 of CISPR 11: 2009. In situ measurements can also be used to confirm the effectiveness of mitigation measures.
RECOMMENDATION ON METHODS OF ELECTROMAGNETIC EMISSIONS REDUCTION
- National power grid: The arc welding machine must be connected to the national power grid in accordance with the manufacturer’s recommendation. If interferences occur, it may be necessary to take additional preventive measures such as the filtering of the power supply network. Consideration should be given to shielding the power supply cable in a metal conduit. It is necessary to ensure the shielding’s electrical continuity along the cable’s entire length. The shielding should be connected to the welding current’s source to ensure good electrical contact between the conduct and the casing of the welding current source.
- Maintenance of the arc welding equipment: The arc welding machine should be submitted to a routine maintenance check according to the manufacturer’s recommendations. All accesses, service doors and covers should be closed and properly locked when the arc welding equipment is on.. The arc welding equipment must not be modified in any way, except for the changes and settings outlined in the manufacturer’s instructions. The spark gap of the arc start and arc stabilization devices must be adjusted and maintained according to the manufacturer’s recommendations.
- Welding cables: Cables must be as short as possible, close to each other, and close to the ground, if not on the ground.
- Electrical bonding : consideration should be given to bonding all metal objects in the surrounding area. However, metal objects connected to the workpiece increase the riskof electric shock if the operator touches both these metal elements and the electrode. It is necessary to insulate the operator from such metal objects.
- Earthing of the welded part: When the part is not earthed – due to electrical safety reasons or because of its size and its location (which is the case with ship hulls or metallic building structures), the earthing of the part can, in some cases but not systematically, reduce emissions It is preferable to avoid the earthing of parts that could increase the risk of injury to the users or damage other electrical equipment. If necessary, it is appropriate that the earthing of the part is done directly, but in some countries that do not allow such a direct connection, it is appropriate that the connection is made with a capacitor selected according to national regulations.
- Protection and plating: The selective protection and plating of other cables and devices in the area can reduce perturbation issues. The protection of the entire welding area can be considered for specific situations.
TRANSPORTATION OF THE MACHINE
It is preferable to drain the cooling unit before transport. Do not place/carry the unit over people or objects.
INSTALLATION
- Put the machine on the floor (maximum incline of 10°.)
- Ensure the work area has sufficient ventilation for welding, and that there is easy access to the control panel.
- The machine must be placed in a sheltered area away from rain or direct sunlight.
- The machine must not be used in an area with conductive metal dust.
- The MULTI COOL 500 machine protection level is IP21, which means:
- Protection against access to dangerous parts from solid bodies of a 12.5mm diameter and,
- Protection against vertically falling drops
- The MULTI COOL 1300 machine protection level is IP23S, which means :
- Protection against access to dangerous parts from solid bodies of a 12.5mm diameter and,
- Protection against the rain inclined at 60% towards the vertical.
- These devices can be used outside in accordance with the IP23S protection index.
- The manufacturer does not incur any responsibility regarding damages to both objects and persons that result from an incorrect and/or dangerous use of the machine.
- The power cables, extensions, and welding cables must be fully uncoiled to prevent overheating.
MAINTENANCE / RECOMMENDATIONS
· Maintenance should only be carried out by a qualified person. Annual
maintenance is recommended. · Ensure the machine is unplugged from the mains,
and wait for two minutes before carrying out maintenance work. DANGER High
Voltage and Currents inside the machine.
· Remove the casing 2 or 3 times a year to remove any excess dust. Take this
opportunity to have the electrical connections checked by a qualified person,
with an insulated tool. · Regularly check the condition of the power supply
cable. If the power cable is damaged, it must be replaced by the manufacturer,
its after-sales service or an equally qualified person. · Ensure the
ventilation holes of the device are not blocked to allow adequate air
circulation.
The cooling liquid must be changed every 12 months in order to avoid sediments
that could block the torch cooling circuit.
Any leak or residual fluid, after use, must be handled within the appropriate
purification factory. If possible, recycle the product. It is prohibited to
empty the product in a river, a sceptic tank or a draining system. The diluted
fluid must not be emptied in the sewers unless authorised by the local
regulations.
INSTALLATION PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the welding equipment. During the installation, the operator must ensure that the machine is disconnected from the mains.
EQUIPMENT DESCRIPTION
The MULTI COOL cooling unit is a system designed to cool the water-cooled
torches connected to all types of welding machines (MIG/MAG and TIG). This
device is autonomous and has its own power supply.
The MULTI COOL 1300 is equipped with water flow protection to protect the
torch against a plug on the water circuit or a deterioration of the torch
beam.
- Water inlet
- Water outlet
- ON/OFF button
- Filling cap
- Flow sensor connector (MULTI COOL 1300 only)
- Tank level indicator
- Power supply cable
- Fuse
POWER SUPPLY
This machine is fitted with a 16A socket type CEE7/7 which must be connected to a single-phase 230V (50 – 60 Hz) power supply fitted with three wires and one earthed neutral. The absorbed effective current (I1eff) is indicated on the machine, for optimal use. Check that the power supply and its protection (fuse and/or circuit breaker) are compatible with the current needed by the machine. In some countries, it may be necessary to change the plug to allow the use at maximum settings.
STARTUP
- Fill the tank (see «Cooling liquid» section below).
- Connect the torch to the Multicool.
- Connect the MULTICOOL power supply cable to a single-phase 230V +/- 15% (50 – 60 Hz) power supply WITH earth.
- This machine must only be used with a single phase electricity supply system with three wires and one earthed neutral The absorbed effective current (I1eff) is indicated on the machine, for optimal use. Check that the power supply and its protection (fuse and/or circuit breaker) are compatible with the current needed by the machine.
- Turn on the MULTICOOL with the ON/OFF button located on the front of the machine.
- After 1 minute, check the coolant level and fill if necessary.
COOLANT
Make sure that the cooling unit is turned off before disconnecting the liquid
inlet and/or outlet hoses of the torch. The coolant is harmful and irritates
the eyes, the mucous membranes and the skin. Hot liquid may cause burns.
Risk of burns due to hot liquid Never drain the cooling unit immediately after
use. The liquid contained inside is boiling, wait until it cools down before
draining.
INITIATING THE COOLANT CIRCULATION
When using the product for the first time or after completely emptying the coolant tank, the following procedure must be followed to start the circulation:
- – Fill the tank to its maximum level with coolant.
- Connect the coolant starting kit to the cold liquid connector on the unit (blue connector).
- Place the other end of the kit in an empty container.
- Switch on the liquid pump. To activate it, depending on the products, it will be necessary to connect a torch and then push the trigger, or simply turn on the device.
- The pump should start instantly and the liquid should flow into the container.
- If the pump still does not start, cut off its supply, inject compressed air into the starting kit to remove the liquid from the pipes and then restart the pump.
- Once the liquid starts flowing, the pump is running.
- Turn off the unit, disconnect the staring kit, refill the coolant in the tank and connect your system to the liquid connectors on the unit.
- Your cooling unit is ready to be operated.
FLOW SENSOR WIRING – MULTICOOL 1300 ONLY (EXAMPLE WITH A MIG TORCH)
SPARE PARTS
1 | ON/OFF button | 52460 |
---|---|---|
2 | Power supply cable | 21487 |
3
| Fuse holder| 51387
Fuse| 51330
4| Water outlet| 71694
5| Water inlet| 71695
6| Retractable handle| 72125
7| Pad| 56120
8| 1.5 L tank| M0228
9| Membrane pump
| 71772
10| Silent block| 71136
11| Vibration absorber| 71966
12| Ventilador| 51023
13| Water radiator| 71751
1 | Pad | 56120 |
---|
2
| 8 L/min pump with integrated fan| ****
71793
3| Water radiator| 71779
4| 7 L tank| 71794
5| Flow sensor connector| 51126
| Water flow sensor| 71795
7| Water inlet| 71695
8| Water outlet| 71694
9| ON/OFF button| 52460
10| Fuse holder| 51387
11| Power supply cable| 21487
12| Filling cap| 71800
13| Drain plug| 71801
| Fuse| 51330
TECHNICAL SPECIFICATIONS
GROUPE FROID / COOLING UNIT| MULTICOOL
500
| MULTICOOL
1300
---|---|---
Primary
Power supply voltage| 230 V +/- 15%
Mains frequency| 50 / 60 Hz
Fuse| 1.6 A
Cooling power at 1l/min at 25°C| ****
465 W
| ****
1 300 W
Correction factor at 40°C| ****
0.574
| ****
–
Maximum pressure| 0.6 MPa| 0.28 MPa
Tank capacity| 1.5 L (0.4 gal)| 7 L
(1.85 gal)
Maximum flow| 6 L/min
(1.6 gal/min)
Functionning temperature| -10° +40°C
Storage temperature| -20° +55°C
Protection level| IP21| IP23S
Dimensions (LxWxH) /| 47 x 24 x 15.5 cm| 70 x 29 x 39 cm
Weight| 8 kg| 19 kg
SYMBOLS
- Warning! Read the user manual before use
- Single phase power supply 50 or 60 Hz
- Assigned voltage
- Hertz
- Assigned voltage
- Volt
- Maximum rated power supply current (effective value).
- Amperes
- Cooling unit system
- Cooling capacity for 1 litre per minute
- Kilowatt
- Maximum outlet pressure
- Megapascal
- Fuse
- Cooling liquid input
- Cooling liquid output
- Maximum coolant level
- Minimum coolant level
- Device complies with europeans directives, The EU declaration of conformity is available on our website
- Equipment in compliance with British requirements. The British Declaration of Conformity is available on our website
- Equipment in conformity with Moroccan standards. The declaration C م (CMIM) of conformity is available on our website
- The device is compliant with standard EN60974-2 and EN60971-10 class A device
- This hardware is subject to waste collection according to the European directives 2012/19/EU. Do not throw out in a domestic bin !
- This product should be recycled appropriately
- EAEC Conformity marking (Eurasian Economic Community).
- Temperature information (thermal protection)
- On (power on) / Off (power off)
- Protected against access to dangerous parts of solid bodies with diam >12.5 mm and protected against rain directed at 60° to the vertical when the moving parts of the device are not yet in operation.
- Protected against access to dangerous parts of solid bodies with a diameter >12.5mm (equivalent to the finger of the hand) and against vertical drops of water
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour). The warranty does not cover:
- Transit damage.
- Normal wear of parts (eg. : cables, clamps, etc..).
- Damages due to misuse (power supply error, dropping of equipment, disassembling).
- Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc …)
- A description of the fault reported
GYS SAS
1, rue de la Croix des Landes CS 54159 53941 SAINT-BERTHEVIN Cedex