SPECIFICATION

Item No

| Range| Resolution| Accuracy| Micrometer head| Anvils types| Protection
---|---|---|---|---|---|---

| mm| inch| mm|

μm

| | |
1105500251| 0-20| 0-0.8”| 0,001| ±4| Friction rotating| Point & Blade 0.75×6.5|

IP-65

FUNCTION

OPERATION

  1. Clean the oil from the measuring surfaces of micrometer by cloth.

  2. If necessary, open the battery cover; insert the battery (type CR2032) according to the polarity of the electrodes. Blinking display information or absence suggests replacing battery. After battery replacement on the screen will be ———- indication. Press SET button for setting 0.000 .

  3. Turn on the display by pressing 0/MODE button.

  4. Check the setting display to zero. Contact with each other (or with setting gauge) measuring surfaces of the anvil and the spindle, using the ratchet and take a measurement.
    Rotation the micrometer screw in the direction of convergence measuring surfaces using the ratchet. ip located at the end of screws, used only for reverse spindle.

  5. For zero setting, press the O/MODE or SET button and hold it to reset to Zero.

  6. After switching on, the display shows the measured value of the metric/ English system of units. Press UNIT button to switch between metric/ English measurement systems.

  7. After switching on, the display shows in absolute or relative terms. Press O/MODE button to switch between absolute and relative measurement

  8. During measure, thimble should rotate only by ratchet. Ensure contact of workpiece with measuring surfaces of the micrometer so tightly to ratchet cranked 2-3 times. Try to prevent warping measuring surfaces.

  9. This micrometer has auto switch off function (10 min non using) ot press UNIT button during 2 sec. to switch off.

  10. After work the measuring surfaces of the micrometer wipe with a cloth and apply ant corrosive oil.

WARNING !

  • Avoid contact with the body electronics unit micrometer emulsions and oils.

  • During the measurements, periodically check the zero setting micrometer.

  • Do not make the rotation of the micrometer screw in close measuring surfaces using a thimble.

  • Avoid shocks or falling, even with a small height.

  • Do not disassemble or adjust the micrometer persons who unrelated to the repair.

CUSTOMERS SUPPORT

MICROTECH
innovative measuring instruments
61001, Kharkiv, Ukraine, str. Rustaveli, 39
tel.: +38 (057) 739-03-50
www.microtech.ua
tool@microtech.ua

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals