welldana DVS050 DVS Pool Lamps Instruction Manual
- June 13, 2024
- welldana
Table of Contents
- Technical specifications
- Remarks
- Box contents
- Installation instructions
- Wiring instructions Setup 1
- Wiring instructions Setup 2
- Retrofit in PAR56 niche (only Vision Spectra 170mm)
- Color programs
- Color Locking (only for TW lamps)
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DVS050 DVS Pool Lamps
Instruction Manual
VISION SpectraManual
DVS050, DVS100 ,DVS170
DVM050 ,DVM100 , DVM170
Visit www.duratech.be for other available languages
Technical specifications
Lamp Type| Description| Voltage| Power| Color temp|
**Luminous flux***
---|---|---|---|---|---
DVS050-RGB
DVS050-TW
DVS050-WH
DVM050-WH| RGB color 50 mm
Tunable white 50mm
Day white 50mm
Low Day white 50mm| 10-14 VAC
10-14 VAC
10-14 VAC
10-14 VAC| 8 W
8 W
10 W
5 W| All colors
2000-17500K
5000K
5000K| 450 lm
550 lm
700 lm
375 lm
DVS100-RGB
DVS100-TW
DVS100-WH
DVM100-WH| RGB color 100mm
Tunable white 100mm
Day white 100mm
Low Day white 100mm| 10-14 VAC
10-14 VAC
10-14 VAC
10-14 VAC| 20 W
20 W
26 W
9 W| All colors
2000-17500K
5000K
5000K| 1550 lm
1500 lm
2300 lm
875 lm
DVS170-RGB
DVS170-TW
DVS170-WH
DVM170-WH
DVM170-RGB| RGB color 170mm
Tunable white 170mm
Day white 170mm
Low Day white 170mm
Low RGB color 170mm| 10-14 VAC
10-14 VAC
10-14 VAC
10-14 VAC
10-14 VAC| 32 W
32 W
40 W
17 W
20 W| All colors
2000-17500K
5000K
5000K
All colors| 2450 lm
2400 lm
3950 lm
1675 lm
1600 lm
(*) Propulsion systems remains a tolerance of +/- 10% on luminous flux
measurements @ 25°C ; 12VAC
For operation only with a safety isolation transformer
Minimum input voltage: (at lamp terminals) | 10 VAC 50 Hz |
---|---|
Nominal input voltage: (at lamp terminals) | 12 VAC 50 Hz |
Maximum input voltage: (at lamp terminals) | 14 VAC 50 Hz |
IEC Protection Class III
Operation on DC voltages is NOT allowed
Maximum water temperature:| +40°C
Lamps have to be kept out of ice zones
---|---
Ingress protection rate:| IP68
measured at 3m max depth = 3m
Remarks
Water conditions
Prevent damage to your pool lamps and wires due to unstable water conditions.
Your local government may have enacted guidelines for your pool water
conditions to apply by. If not we strongly advise the following parameter
specifications to be applied:
pH level | 6,8 – 7,6 |
---|---|
Free Chlorine | max. 3ppm |
Combined chlorine | max. 1 ppm |
Water temperature | max +40°C and lamps need to be kept out of ice zones |
Always adhere to the instructions provided by your chemical brand/supplier for
the correct use and application of pool chemicals.
Salt water pools, or pools fitted with a salt water chlorine generator contain
salt in the pool water. Salt is a corrosive material. Overdosage and/or
consistent levels of salt increase the possibility of deterioration of your
pool lamps and cables. As a rule of thumb, a concentration of 35gr/l salt can
be accepted when pH values are between 7,2-7,4. In any case, we urge proper
use, care and maintenance of your installation, in order to minimize the
effect of corrosion and deterioration.
Please be aware that pool lamps and cables with defects caused due to
abnormalities in the water condition are not covered by our factory warranty.
Installation/maintenance
The luminaire is maintenance free
If the luminaire needs to be replaced, it needs to be completely removed
from the water If the external flexible cable or cord of this luminaire is
damaged, it shall be exclusively replaced by the manufacturer or his service
agent or a similar qualified person in order to avoid hazard
Vision Spectra Pool lamps must be completely submerged into water during
operation. Fixing the lamps with adhesives or silicone kit into a niche is not
allowed Not following these instructions, will void warranty.
Box contents
Installation instructions
mounting face plate mounting the connector Connector installation
Wiring instructions Setup 1
For new installations
Each lamp is connected to the transformer by a separate cable ** Always use a toroïdal transformer
SELECT CABLE SECTION & MAXIMUM LENGTH**
| LAMP TYPE| 1,5mm 2| 2,5mm2| 4,0mm 2| 6,0mm2|
10mm2| **VA TRANSFORMER (12VAC)***
---|---|---|---|---|---|---|---
| DVS050-TW
DVS050-RGB
DVS050-WH| 75m| 125m| 200m| 300m| 500m| 13 VA
DVM050-WH| 150m| 250m| 400m| 600m| 1000m| 7 VA
| DVS100-TW
DVS100-RGB
DVS100-WH| 25m| 45m| 75m| 115m| 195m| 34 VA
DVM100-WH| 85m| 140m| 200m| 300m| 550m| 12 VA
| DVS170-TW
DVS170-RGB
DVS170-WH| 20m| 30m| 50m| 75m| 125m| 52 VA
DVM170-WH| 45m| 75m| 120m| 180m| 300m| 22 VA
DVM170-RGB| 35m| 60m| 100m| 150m| 250m| 26 VA
STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED
CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE
The transformer VA rating must be greater or equal to the sum of VA ratings of
all connected lamps.
These cable lenghts are calculated with worst case voltage drops in the
electrical wiring.
Wiring instructions Setup 2
For existing or other installations
All lamps are connected to the transformer via 1 cable **** Always use a toroïdal transformer
SELECT CABLE SECTION & MAXIMUM LENGTH
| LAMP TYPE| QTY| 2,5mm2| 4,0mm 2| 6,0mm 2| 10mm
2| VA TRANSFORMER (12VAC)
---|---|---|---|---|---|---|---
| DVS050-TW
DVS050-RGB
DVS050-WH| 1
2
3
4| 125m
63m
42m
31m| 200m
100m
67m
50m| 300m
150m
100m
75m| 500m
250m
167m
125m| 13
26
39
52
DVM050-WH| 1
2
3
4| 250m
125m
83m
63m| 400m
200m
133m
100m| 600m
300m
200m
150m| 1000m
500m
333m
250m| 7
14
21
28
| DVS100-TW
DVS100-RGB
DVS100-WH| 1
2
3
4| 45m
23m
15m
11m| 75m
38m
25m
19m| 115m
58m
38m
29m| 195m
98m
65m
49m| 34
68
102
136
DVM100-WH| 1
2
3
4| 140m
70m
47m
35m| 75m
38m
25m
19m| 300m
150m
100m
75m| 550m
275m
183m
138m| 12
24
36
48
| DVS170-TW
DVS170-RGB
DVS170-WH| 1
2
3
4| 30m
15m
10m
8m| 50m
25m
17m
13m| 75m
38m
25m
19m| 125m
63m
42m
31m| 52
104
156
208
DVM170-WH| 1
2
3
4| 75m
38m
25m
19m| 120m
60m
40m
30m| 180m
90m
60m
45m| 300m
150m
100m
75m| 22
44
66
88
DVM170-RGB| 1
2
3
4| 60m
30m
20m
15m| 100m
50m
33m
25m| 150m
75m
50m
38m| 250m
125m
83m
63m| 26
52
78
104
STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE
Retrofit in PAR56 niche (only Vision Spectra 170mm)
Color programs
RGB LAMPS
1 | CANDLE LIGHT | 2000K very warm white |
---|---|---|
2 | WARM WHITE | 3000K warm white |
3 | NEUTRAL WHITE | 5000K neutral white |
4 | COLD WHITE | 9500K cold white |
5 | CARIBEAN BLUE | cyan |
6 | BLUE | blue |
7 | GREEN | green |
8 | RED | red |
9 | PURPLE | purple |
10 | YELLOW DYNAMIC | slow animation yellow |
11 | BLUE DYNAMIC | fast animation blue |
TW LAMPS
1 | CANDLE LIGHT | 2000K |
---|---|---|
2 | WARM WHITE | 3000K |
3 | NEUTRAL WHITE | 5000K |
4 | COLD WHITE | 9500K |
5 | BLUE-WHITE | 13500K |
6 | COOL BLUE | 17500K |
Synchronizing & color changing (for RGB and TW lamps only)
Manual synchronization
- Switch ON the 12 VAC line voltage and make sure that all lamps light up.
- Switch OFF the 12 VAC line voltage and wait for at least 20 sec (max 60 sec)
- Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF)
- Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF)
- Switch ON
- The lamps should now all be on color program 6: Blue
- TW lamps: the lamps will all flicker after 15 seconds on color program 6. You can now choose to lock the lamp on a desired color program by switching off/on within the next 5 seconds. After 5 seconds the flickering will stop and the lamp is locked.
See next page for details. If you did not select a color when flickering, the lamps will stop flickering after 5 seconds and the lamp will be unlocked.
Changing colors
Quickly turn the lamps OFF and back ON
The lamp will jump to the next color program
Memorizing the actual color
Turn the lamp OFF for MINIMUM 20 seconds
The last chosen color has now been memorized
Color Locking (only for TW lamps)
If desired, TW lamps can be “locked” on a color program of choice. This means
the lamp will only light up in that specific color, and it is no longer
possible to change the color program of the lamp.
This process can be reversed anytime by “unlocking” the color program. All
color programs will then be available again, and can be changed at any time.
Locking/Unlocking procedure
Locking the color of a lamp starts with a synchronisation procedure:
- Switch ON the 12 VAC line voltage
- Switch OFF the 12 VAC line voltage and wait for at least 20 sec (max 60 sec)
- Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF)
- Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF)
- Switch ON
- Wait for about 15 seconds. The lamp(s) will now flicker
LOCKING: – during the flickering of the lamp, select the desired color program by switching (within 5 seconds) the lamps OFF and ON quickly.
– When the right color is selected, then wait 5 seconds, until the flickering stops
– The lamp is now locked on the chosen color program
UNLOCKING: – When the lamps flicker, then do nothing for 5 seconds.
– The flickering will stop, and it is again possible to change the color program of the lamps.
Troubleshooting
PROBLEM | SOLUTION |
---|---|
The pool light is flickering | 1. Switch the lamps ON and select Cold white |
color program
2. Remove the lamp from the water, unscrew the fix nut, pull back the gasket
and the black cable jacket, so you can reach the brass contacts inside the
connector block (do not remove the connector block)
3. Measure the voltage at the lamp terminals (while the lamp is still ON)
4. The voltage at the lamp should be at least 10VAC 50Hz. If the measured
line voltage is below 10VAC:
A. Check the output voltage at the transformator terminals. This voltage
should be between 12VAC and 14VAC. Verify that the used transformator VA
rating is sufficient for powering all connected lamps
B. If the transformator output voltage is ok, then install a thicker cable
between the transformator and the lamp. (wiring instructions p. 10-13)
In case of TW lamps: make sure the lamp is not in color locking mode
Several pool lights in the pool show different
color programs| Make sure that all lamps are connected to the same 12VAC power
line. Execute the synchronization as explained on p.16
Declaraction of Conformity
Declarations of conformity covering this product are available for download
from the House of Duratech website:
www.duratech.be
Contact details
Propulsion Systems bv
Dooren 72
1785 Merchtem, Belgium
Tel +32 2 461 02 53
www.duratech.be
info@propulsionsystems.be
http://www.propulsionsystems.be
We reserve the rights to change all or part of the contents of this document
without prior notice
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>