ABB 1SAM350200R1002 Motor Protection Switch For Railways User Manual

June 13, 2024
ABB

ABB 1SAM350200R1002 Motor Protection Switch For Railways

Product Information

  • Product Name: MS132-0.25B Manual Motor Starter
  • Product ID: 1SAM350200R1002
  • EAN: 4013614521324
  • Catalog Description: MS132-0.25B Manual Motor Starter 0.16 … 0.25 A

Description: MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm. It complies with the latest railway rolling stock standards and allows installation in passengers or driver cabins for trains frequently operating in tunnels or undergrounds. The manual motor starter offers reliable protection for motors in the event of overload or phase failure. It has a trip class 10 and a clear indication of fault in a separate window in case of short-circuit tripping. The device also features a built-in disconnect function, temperature compensation, trip-free mechanism, and a lockable rotary handle with a clear switch position indication. It is suitable for three- and single-phase applications.
Auxiliary contacts, signaling contacts, under voltage releases, shunt trips, and power in-feed blocks are available as accessories.

Product Usage Instructions

  1. Ensure that the power supply to the motor is disconnected before installing or operating the MS132-0.25B Manual Motor Starter.
  2. Choose the appropriate accessories, if required, for your specific application.
  3. Mount the MS132-0.25B Manual Motor Starter on a DIN rail, following the recommended mounting position and minimum mounting distance guidelines.
  4. Connect the main circuit wires to the terminal using the recommended tightening torque and stripping length.
  5. Check that the actuator type and contact position indication align with your motor control requirements.
  6. Once the connections are secure, restore the power supply to the motor.
  7. Use the lockable rotary handle to select the desired motor operation mode.
  8. Monitor the separate fault indication window for any short-circuit tripping or other faults.
  9. If any unauthorized changes need to be prevented, ensure that the handle is locked.
  10. Regularly inspect and maintain the MS132-0.25B Manual Motor Starter for optimal performance and safety.

Note: The product specifications and features mentioned above are subject to change without notice. Please refer to the latest version of the user manual for accurate information.

General Information

  • Extended Product Type :MS132-0.25B
  • Product ID : 1SAM350200R1002
  • EAN : 4013614521324
  • Catalog Description :  MS132-0.25B Manual Motor Starter 0.16 … 0.25 A
  • Long Description MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.
  • They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.
  • This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single phase applications.
  • The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, under voltage releases, shunt trips, power in-feed blocks are available as accessory.

These are suitable throughout the MS132-B/MS165-B range.

  • designed in accordance to the applicable parts of IEC 60077 standard
  • shocks and vibration withstand conforming to IEC 61373 (category 1, class B)
  • usable according to European fire and smoke safety standard EN 45545-2

Ordering

  • Minimum Order Quantity 1 piece
  • Customs Tariff Number 85362010

Popular Downloads

  • Data Sheet, Technical  Information :1SBC100200C02__
  • Instructions and Manual s :2CDC131022M6802
  • Instructions and Manuals (Part 2)   :2CDC131060M0202
  • Time-Current Characteristic Curve : 1SAM300505F0102
    • 1SAM300507F0001
    • 1SAM300507F0003
  • I²t Characteristic
    • 1SAM300508F0001
    • 1SAM300508F0003
  • Cut-off Current
    • Characteristic
  • CAD Dimensional 2CDC001079B0201

Dimensions

  • Product Net Width 45 mm
  • Product Net Height 90 mm
  • Product Net Depth  Length / 86.75 mm
  • Product Net Weight 0.215 kg

Technical

  • Rated Service Short-  Circuit Breaking Capacity (Ics)
    • (230 V AC) 100 kA
    • (250 V DC) 3 Poles in Series 10 kA
    • (400 V AC) 100 kA
    • (440 V AC) 100 kA
    • (500 V AC) 100 kA
    • (690 V AC) 100 kA
  • Rated Ultimate Short- Circuit Breaking Capacity (Icu)
    • (230 V AC) 100 kA
    • (400 V AC) 100 kA
    • (440 V AC) 100 kA
    • (500 V AC) 100 kA
    • (690 V AC) 100 kA
  • Rated Instantaneous Short-Circuit Current Setting (Ii) :  3.1 A
  • Setting Range :0.16 … 0.25 A
  • Rated Operational Power  AC-3 (Pe) (400 V) Three Phase 0.06 kW
  • Rated Operational Power  AC-3e (Pe) (400 V) Three Phase 0.06 kW
  • Rated Operational Voltage
  • Main Circuit 690 V AC
  • Main Circuit 250 V DC
  • Rated Operational Current (Ie) : 0.25 A
  • Rated Operational Current  AC-3 (Ie ): 0.25 A
  • Rated Operational Current  AC-3e (Ie) :0.25 A
  • Rated Operational Current
  • DC-5 (Ie) : 0.25 A
  • Main Circuit 50 Hz
  • Main Circuit 60 Hz
  • Rated Frequency (f)
  • Rated Impulse Withstand  Voltage (Uimp )  :  Main Circuit 6 kV
  • Rated Insulation Voltage (Ui) :  690 V
  • Power Loss :at Rated Operating Conditions per Pole 0.7 … 1.6 W
  • Number of Poles: 3
  • Conventional Free-air  Thermal Current (Ith) : Main Circuit 0.25 A
  • Degree of Protection :   Housing IP20 Main Circuit Terminals IP1
  • Pollution Degree : 3
  • Electrical Durability :50000 cycle
  • Mechanical Durability :100000 cycle
  • Terminal Type : Screw Terminals
  • Connecting Capacity Main Circuit
    • Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
    • Flexible with Insulated Ferrule 1/2x 0.75 … 2.5 mm²
    • Flexible 1/2x 0.75 … 2.5 mm²
    • Rigid 1/2x 1 … 4 mm²
  • Tightening Torque : Main Circuit 0.8 … 1.2 N·m
  • Wire Stripping Length : Main Circuit 9 mm
  • Recommended Screw  Driver : Pozidriv 2
  • Mounting Position :  1 … 6
  • TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
  • TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting on DIN Rail
  • Minimum Mounting Distance
    • Electrical Conductive Board, Horizontal – Up to 400 V 0 mm
    • Electrical Conductive Board, Horizontal – Up to 690 V 1.5 mm
    • Electrical Conductive Board, Vertical 75 mm
    • Other Device Same Type, Horizontal 0 mm
    • Other Device Same Type, Vertical 150 mm
  • Actuator Typ e : Rotary Handle
  • Contact Position  Indication :ON / OFF / TRIP
  • Standards
    • IEC 60077-1 (applicable parts)
    • IEC 60077-2 (applicable parts)
    • IEC/EN 60947-1
    • IEC/EN 60947-2
    • IEC/EN 60947-4-1
  • Remarks
    • UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical UL/CSA

  • Short-Circuit Current : Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47
  • Rating (SCCR)
    • Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
    • Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
    • Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
    • Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
    • Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group
    • Installations (480Y / 277 V AC) 65 kA
    • Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group
    • Installations (600Y / 347 V AC) 47 kA
  • Maximum Operating : Main Circuit
  • Full Load Amps Motor Use
    • 600 V AC Voltage UL/CSA
    • (200 V AC) Three Phase 0.25 A
    • (208 V AC) Three Phase 0.25 A
    • (220 … 240 V AC) Three Phase 0.25 A
    • (440 … 480 V AC) Three Phase 0.25 A
    • (550 … 600 V AC) Three Phase 0.25 A
  • Locked Rotor Amps
    • (200 V AC) Three Phase 1.5 A
    • (208 V AC) Three Phase 1.5 A
    • (220 … 240 V AC) Three Phase 1.5 A
    • (440 … 480 V AC) Three Phase 1.5 A
    • (550 … 600 V AC) Three Phase 1.5 A
  • General Use Rating  UL/CSA :(600 V AC) 0.25 A
  • Connecting Capacity Main Circuit UL/CSA
    • Flexible 1/2x 16-12 AWG
    • Stranded 1/2x 16-12 AWG
  • Tightening Torque :Main Circuit 10 … 12 in·lb

Environmental

  • Ambient Air Temperature Yes
    • Around the Enclosure 0 … +40 °C
    • Operation -25 … +70 °C
    • Operation Compensated -25 … +60 °C
    • Storage -50 … +80 °C
  • Ambient Air Temperature Compensation : Yes
  • Maximum Operating  Altitude Permissibl e : 2000 m
  • Shock and Vibration  Withstand acc to IEC  61373 :Category 1, Class B
  • Resistance to Shock acc  to IEC 60068-2-27 : 11 ms Pulse 25g
  • Resistance to Vibrations   acc. to IEC 60068-2-6 :   5g / 3 … 150 Hz
  • RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Certificates and Declarations

  • CB Certificate: 1SAA963002-2002
  • CQC Certificate : CQC2010010307387700
  • Cut-off Current  :1SAM300508F0001
  • Characteristic :1SAM300508F0003
  • Declaration of Conformity 2020980307003526 – CCC
  • Declaration of Conformity 1SAD101100-3407 – CE
  • Declaration of Conformity 1SAD201100-3407 – UKCA
    • 1SAM300507F0001
    • 1SAM300507F0003
  • I²t Characteristic
  • KC Certificate 1SAA963002-1502
  • UL CertificateE137861-20090225
    • E345003-20090225

Container Information

  • Package Level 1 Units box 1 piece
  • Package Level 1 Width 92 mm
  • Package Level 1 Depth  Length / 95 mm
  • Package Level 1 Height 50 mm
  • Package Level 1 Gross Weight  0.23 kg
  • Package Level 1 EAN 4013614521324
  • Package Level 2 Units carton 40 piece
  • Package Level 2 Width 280 mm
  • Package Level 2 Depth  Length / 395 mm
  • Package Level 2 Height 210 mm
  • Package Level 2 Gross  Weight 14.026 kg
  • Package Level 2 EAN 4013614522918

Classifications

  • Object Classification Code : F
  • ETIM 5 :EC000074 – Motor protective circuit-breaker
  • ETIM 6 : EC000074 – Motor protection circuit-breaker
  • ETIM 7 : EC000074 – Motor protection circuit-breaker
  • ETIM 8 :EC000074 – Motor protection circuit-breaker
  • eClass : V11.0 : 27370401
  • UNSPSC : 39121521
  • IDEA Granular Category Code (IGCC) 4731 >> Manual Starters

Accessories

Identifier                                    Description Type Quantity| Measure
---|---
1SAM201901R1001| HKF1-11 Auxiliary Contact| HKF1-11| 1| piece
1SAM201901R1201| HKF1-11K Auxiliary Contact| HKF1-11K| 1| piece
1SAM201901R1002| HKF1-20 Auxiliary Contact| HKF1-20| 1| piece
1SAM201901R1202| HKF1-20K Auxiliary Contact| HKF1-20K| 1| piece
1SAM201901R1004| HKF1-01 Auxiliary Contact| HKF1-01| 1| piece
---|---|---|---|---
1SAM201901R1003| HKF1-10 Auxiliary Contact| HKF1-10| 1| piece
1SAM201902R1002| HK1-20 Auxiliary Contact| HK1-20| 1| piece
1SAM201902R1202| HK1-20K Auxiliary Contact| HK1-20K| 1| piece
1SAM201902R1001| HK1-11 Auxiliary Contact| HK1-11| 1| piece
1SAM201902R1201| HK1-11K Auxiliary Contact| HK1-11K| 1| piece
1SAM201902R1003| HK1-02 Auxiliary Contact| HK1-02| 1| piece
1SAM201902R1203| HK1-02K Auxiliary Contact| HK1-02K| 1| piece
1SAM201902R1004| HK1-20L Auxiliary Contact| HK1-20L| 1| piece
1SAM201902R1204| HK1-20LK Auxiliary Contact| HK1-20LK| 1| piece
1SAM201903R1002| SK1-20 Signaling Contact| SK1-20| 1| piece
1SAM201903R1202| SK1-20K Signaling Contact| SK1-20K| 1| piece
1SAM201903R1005| SK1-20AR Signaling Contact| SK1-20AR| 1| piece
1SAM201903R1205| SK1-20ARK Signaling Contact| SK1-20ARK| 1| piece
1SAM201903R1001| SK1-11 Signaling Contact| SK1-11| 1| piece
1SAM201903R1201| SK1-11K Signaling Contact| SK1-11K| 1| piece
1SAM201903R1004| SK1-11AR Signaling Contact| SK1-11AR| 1| piece
1SAM201903R1204| SK1-11ARK Signaling Contact| SK1-11ARK| 1| piece
1SAM201903R1003| SK1-02 Signaling Contact| SK1-02| 1| piece
1SAM201903R1203| SK1-02K Signaling Contact| SK1-02K| 1| piece
1SAM201903R1006| SK1-02AR Signaling Contact| SK1-02AR| 1| piece
1SAM201903R1206| SK1-02ARK Signaling Contact| SK1-02ARK| 1| piece
1SAM301901R1002| CK1-20 Short Circuit Signaling Contact| CK1-20| 1| piece
1SAM301901R1001| CK1-11 Short Circuit Signaling Contact| CK1-11| 1| piece
1SAM301901R1003| CK1-02 Short Circuit Signaling Contact| CK1-02| 1| piece
1SAM201910R1001| AA1-24 Shunt Trip| AA1-24| 1| piece
1SAM201910R1002| AA1-110 Shunt Trip| AA1-110| 1| piece
1SAM201910R1003| AA1-230 Shunt Trip| AA1-230| 1| piece
1SAM201910R1004| AA1-400 Shunt Trip| AA1-400| 1| piece
1SAM201904R1010| UA1-20 Undervoltage Release| UA1-20| 1| piece
1SAM201904R1001| UA1-24 Under voltage Release| UA1-24| 1| piece
1SAM201904R1002| UA1-48 Under voltage Release| UA1-48| 1| piece
1SAM201904R1003| UA1-60 Under voltage Release| UA1-60| 1| piece
1SAM201904R1004| UA1-110 Under voltage Release| UA1-110| 1| piece
1SAM201904R1008| UA1-208 Under voltage Release| UA1-208| 1| piece
1SAM201904R1005| UA1-230 Under voltage Release| UA1-230| 1| piece
1SAM201904R1006| UA1-400 Under voltage Release| UA1-400| 1| piece
1SAM201904R1007| UA1-415 Under voltage Release| UA1-415| 1| piece
1SAM201904R1009| UA1-575 Under voltage Release| UA1-575| 1| piece
1SAM201906R1102| PS1-2-0-65 Busbar| PS1-2-0-65| 1| piece
1SAM201906R1112| PS1-2-1-65 Busbar| PS1-2-1-65| 1| piece
1SAM201906R1122| PS1-2-2-65 Busbar| PS1-2-2-65| 1| piece
1SAM201916R1103| PS1-3-0-100 Busbar| PS1-3-0-100| 1| piece
1SAM201906R1103| PS1-3-0-65 Busbar| PS1-3-0-65| 1| piece
1SAM201916R1113| PS1-3-1-100 Busbar| PS1-3-1-100| 1| piece
1SAM201906R1113| PS1-3-1-65 Busbar| PS1-3-1-65| 1| piece
1SAM201916R1123| PS1-3-2-100 Busbar| PS1-3-2-100| 1| piece
---|---|---|---|---
1SAM201906R1123| PS1-3-2-65 Busbar| PS1-3-2-65| 1| piece
1SAM201916R1104| PS1-4-0-100 Busbar| PS1-4-0-100| 1| piece
1SAM201906R1104| PS1-4-0-65 Busbar| PS1-4-0-65| 1| piece
1SAM201916R1114| PS1-4-1-100 Busbar| PS1-4-1-100| 1| piece
1SAM201906R1114| PS1-4-1-65 Busbar| PS1-4-1-65| 1| piece
1SAM201906R1124| PS1-4-2-65 Busbar| PS1-4-2-65| 1| piece
1SAM201916R1105| PS1-5-0-100 Busbar| PS1-5-0-100| 1| piece
1SAM201906R1105| PS1-5-0-65 Busbar| PS1-5-0-65| 1| piece
1SAM201916R1115| PS1-5-1-100 Busbar| PS1-5-1-100| 1| piece
1SAM201906R1115| PS1-5-1-65 Busbar| PS1-5-1-65| 1| piece
1SAM201906R1125| PS1-5-2-65 Busbar| PS1-5-2-65| 1| piece
1SAM201907R1101| S1-M1-25 Power Infeed Block| S1-M1-25| 1| piece
1SAM201907R1102| S1-M2-25 Power Infeed Block| S1-M2-25| 1| piece
1SAM201907R1103| S1-M3-25 Power Infeed Block| S1-M3-25| 1| piece
1SAM201913R1103| S1-M3-35 Power Infeed Block| S1-M3-35| 1| piece
1SAM201914R1002| S1-PB1-25 Power Infeed Block| S1-PB1-25| 1| piece
1SAM301911R1001| TS1-M3-S1 Terminal Spacer| TS1-M3-S1| 1| piece
1SAM301912R1001| TS1-M3-S2 Terminal Spacer| S1-M3-S2| 1| piece
1SAM201908R1001| BS1-3 Protection Cover| BS1-3| 1| piece
1SAM201909R1001| FS116 Screw Fixing Kit| FS116| 1| piece
1SAM201914R1001| PB1-1-32 Connecting Link| PB1-1-32| 1| piece
GJF1101903R0002| SA2 Terminals and Installation Material| SA2| 1| piece
1SAM201911R1012| IB132-F Enclosure| IB132-F| 1| piece
1SAM201911R1010| IB132-G Enclosure| IB132-G| 1| piece
1SAM201911R1011| IB132-Y Enclosure| IB132-Y| 1| piece
1SAM201912R1010| DMS132-G Door Mounting Kit| DMS132-G| 1| piece
1SAM201912R1011| DMS132-Y Door Mounting Kit| DMS132-Y| 1| piece
1SAM201909R1021| MSAH1 Shaft Supporter| MSAH1| 1| piece
1SAM201920R1011| MSHD-LTB Handles| MSHD-LTB| 1| piece
1SAM201920R1012| MSHD-LTY Handles| MSHD-LTY| 1| piece
1SAM101923R0002| MSMN Driver| MSMN| 1| piece
1SAM101923R0012| MSMNO Driver| MSMNO| 1| piece
1SCA101647R1001| OXS6X85 SHAFT| OXS6X85| 1| piece
1SCA108043R1001| OXS6X105 SHAFT| OXS6X105| 1| piece
1SCA101655R1001| OXS6X130 SHAFT| OXS6X130| 1| piece
1SCA101659R1001| OXS6X180 SHAFT| OXS6X180| 1| piece

Categories

  • Low Voltage Products and Systems → Circuit Breakers → Manual Motor Starters
  • Low Voltage Products and Systems → Control Products → Manual Motor Starters → Manual Motor Starters

© 2023 ABB. All rights reserved.

  • 2023/08/10
  • Subject to change without notice
  • MS132-0.25B

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals