 SPECIFICATION

Item No| Range| Resol.| Accu- racy| Hyste- resis| Force| Preset| Go/NoGo| Max/Min| Formula| Timer| Temp comp| Linear corr| Calibr date| Connect. status| Recharge batt| Memory| Wireless| USB| Color Display
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
| mm| inch| mm| μm| μm| N| Functions
120129133| 0-13| 0-0,5”| 0,0001 / 0.001 / 0.01 /| ±5|

0,5

| 0,6-1| •| •| •| •| •| •| •| •| •| •| Folders / 2000 val| Long range / HID| USB HID / Update| Touchscreen 1,54”
120129135| ±3| •| •| •| •| •| •| •| •| •| •
120129137| ±2| •| •| •| •| •| •| •| •| •| •
120129138| ±1.6| •| •| •| •| •| •| •| •| •| •
120129252| 0-25,4| 0-1”| ±7| 0.7-1.2| •| •| •| •| •| •| •| •| •| •
120129253| ±5| •| •| •| •| •| •| •| •| •| •
120129257| ±3| •| •| •| •| •| •| •| •| •| •
120129258| ±2| •| •| •| •| •| •| •| •| •| •
120129503| 0-50,8| 0-2”| ±10| 1,2-2,2| •| •| •| •| •| •| •| •| •| •
120129507| ±4| •| •| •| •| •| •| •| •| •| •
120129508| ±3| •| •| •| •| •| •| •| •| •| •
120129903| 0-100| 0-4”| ±15| 3.2-5.2| •| •| •| •| •| •| •| •| •| •
120129907| ±5| •| •| •| •| •| •| •| •| •| •

‘TECHNICAL DATA

Parameters|
---|---
|
LED display| color 1,54 inch
Resolution| 240×240
Indication system| MICS 4.0
Power supply| Rechargeable Li-Pol battery
Battery capacity| 450 mAh
Charging port| micro-USB / Magnetic port
Case material| Aluminium
Buttons| Switch (Multifuntional), Reset
Wireless data transfer| Ultra long range
USB data transfer| USB HID

MAIN INFO

SWITCH ON DEVICE – button push (1 sec)
SWITCH OFF DEVICE – button push (2 sec)/ auto switch off
DATA TRANSFER – programming throw menu
Device Using Instruction
BUILT-IN BATTERY – rechargeable Li-Pol battery
For charging connect USB cable

 DIMESIONAL DRAWINGS

Dimension

DATA TRANSFER

3 MODES OF DATA TRANSFER (USB + 2 WIRELESS MODES)
Connection

WIRELESS CONNECTION TO MDS app

FREE SOFTWARE
WIRELESS data transfer to MICROTECH MDS app for Windows, Android, iOS
**

**

**WIRELESS HID CONNECTION

** WIRELESS HID data transfer (like keyboard) direct to any customers app and system

**USB HID CONNECTION




USB HID data transfer (like keyboard) direct to any customers app and system

7 WAYS HOW TO TRANSFER DATA TO PC OR TABLET

  • TOUCHSCREEN TAP

  • BUTTON PUSH

  • SELECTED FORCE
    Connection

  • BY TIMER

  • FROM MEMORY

  • IN MDS APP
    Configuration

  • FROM PAIRED DEVICE
    Device

MAIN SCREEN

Configuration

  • IRELESS DISCONNECTED

  • WIRELESS CONNECTED

  • WIRELESS HID CONNECTED

  • USB HID CONNECTED

  • USB HID DISCONNECTED

MEMORY

For save measuring data to internal device memory touch data area on screen or button push. You can view saved data throw menu or send Wireless or USB connection to Windows PC, Android or iOS devices.

It’s possible to use Standard or Folders system with 2000 values in memory.

  • FOLDERS SYSTEM

  • MEMORY 2000 val

  • MEMORY EXPORT

  • STATISTIC
    Configuration

Basic STATISTIC functions:

  • MAX – maximum saved value
  • MIN – minimum saved value
  • AVG – average value
  • D -difference between MAX & MIN

STANDARD or FOLDER system can be activated throw MEMORY menu

MENU CONFIGURATION
Configuration
USE TOUCHSCREEN TO OPERATE MENU SWIPE TO MOVE INSIDE

Configuration
z

Configuration

FUNCTIONS

**LIMITS mode GO/NOGO

MAX – NoGo more Upper limit
MIN – NoGo less Lower limit
RANGE – Go between Limitscc
COLOR INDICATION LIMITS ON MAIN SCREEN Go NoGo
Configuration
PEAK mode MAX/MIN

INDICATION AND SAVING MAX OR MIN VALUES
Configuration
TIMER mode

SAVING DATA TO MEMORY OR SENDING WIRELESS/USB BY TIMER
Configuration
FORMULA mode

RESOLUTION selection
Resolution

DISPLAY settings
Light Icon
Configuration
LINEAR error compensation

Re-calculation detail size to calibration conditions (20°C)

WIRELESS data transfer

Configuration**

USB OTG data transfer

**RESET to Factory settings

**

EXTRA

Configuration
RESET to Factory settingsRESET to Factory settingsz MEMORY manager setting
Download Icon

QR Link to MICROTECH web site page with MDS Software download

  • Android, iOS, Windows versions
  • Free and Pro versions
  • Manuals



**CALIBRATION date info

Device INFO

** Information about device

  • Firmware version
  • MAC adress for WIRELESS connection

INDUSTRY 4.0 INSTRUMENTS

Instrument
Instrument

Instrument

MICROTECH
innovative measuring instruments
61001, Kharkiv, Ukraine, str. Rustaveli, 39
tel.: +38 (057) 739-03-50
www.microtech.ua
tool@microtech.ua

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals