MICROTECH 25111026 Dial Indicator Calibration Stand User Manual

June 13, 2024
microtech

MICROTECH 25111026 Dial Indicator Calibration Stand

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-
PRODUCT

MICROTECH Dial Indicator Calibration Stand

User Manual
Calibration ISO 17025:2017
ISO 9001:2015

Non-Rotating Positioning scale
Preset Go/NoGo Max/Min Formula Timer Temp comp Linear corr Calibr date Connect. status Recharge batt Memory Wireless

USB Color Display
Folders / 2000 val Long range / HID USB HID / Update Touchscreen 1,54

Specification

Item No Type Calibr. Range Resol Range Accur.
25111026 Dial 0-25 mm 0.0001 mm 25 m
25111027 Dial 0-50 mm 0.0001 mm 50 m
25111051 Dial & Lever 0-25 mm 0.001 mm 25 m
25113025 Dial 0-50 mm 0.001 mm 50 m
25113027 Dial & Lever 0-100 mm 0.001 mm 100 m
25113050 Dial & Lever 0-150 mm 0.001 mm 150 m
25113100 Dial & Lever 0-8 inch 0.0001 inch 8 m
25113150 Dial & Lever 0-150 mm 0.001 mm 150 m

Technical Data

  • Parameters:
  • LED display Indication system
  • Power supply Charging port
  • Case material Wireless data transfer
  • USB data transfer color 2.4 inch 320×240 MICS 4.0
  • Rechargeable Li-Pol battery 500 mAh micro-USB
  • Aluminium Long range / HID USB HID

Switch On/Off and Data Transfer

SWITCH ON DEVICE – button push (1 sec) SWITCH OFF DEVICE – button push (3 sec)/ auto switch off DATA TRANSFER – programming throw menu BUILT-IN BATTERY – rechargeable Li-Pol battery 3 MODES OF DATA TRANSFER (USB + 2 WIRELESS MODES) WIRELESS CONNECTION TO MDS APP WIRELESS data transfer to MICROTECH MDS app for Windows, Android,iOS SAVING DATA TO XLS. CSV FORMATS FREE SOFTWARE TRANSFER DATA TO CAD, SPC OR OTHER SOFTWARE NO DONGLE TRANSFER DATA TO EXCEL OR OTHER TABLE EDITORS WIRELESS HID CONNECTION USB HID CONNECTION
NO DONGLE WIRELESS HID and USB HID data transfer (like keyboard) direct to any customers app and system SAVING GRAPH TRANSFER DATA TO CAD, SPC OR OTHER SOFTWARE TRANSFER DATA TO EXCEL OR OTHER TABLE EDITORS TRANSFER DATA TO ANY BROWSWE OR APP

Product Usage Instructions

Memory and Data Saving
STANDARD or FOLDER system can be activated through MEMORY menu.
To save measuring data to internal device memory, touch the data area on the screen or press the button. You can view saved data or send it via WIRELESS or USB connection to a Windows PC, Android, or iOS device. It’s possible to use Standard or Folders memory modes.

Analog Scale and Probe Mode
ANALOG SCALE can be used in PROBE MODE. ON-LINE GRAPHIC MODE
FOLDERS SYSTEM MEMORY 2000 VAL. MEMORY EXPORT STATISTIC MAIN SCREEN on 2D mode 2D AND HUB MODE
PROBE – Saving data when Probe will reach value
PROBE Auto – Saving data when Probe will reach value with this value compensation
2D – 2 axis data reading
2D Sync- Synchronized 2 axis data reading

Functions

  • LIMITS mode GO/NOGO
  • COLOR INDICATION LIMITS ON MAIN SCREEN Go NoGo
  • MAX – NoGo more Upper limit
  • Upper limit
  • MIN – NoGo less Lower limit
  • RANGE – Go between Limits
  • NONE – Analog scale active
  • Lower limit Yellow zone on analog scale

PEAK mode MAX/MIN

  • INDICATION AND SAVING MAX OR MIN VALUES
  • DISABLE – non-active mode
  • ENABLE – activating mode
  • MAX – indicating MAX measured value
  • REFRESH – refresh peak value
  • MIN – indicating MIN measured value according to timer

TIMER mode
SAVING DATA TO MEMORY OR SENDING WIRELESS/USB BY TIMER

FORMULA mode
Select timer period
Reset to deactivate mode

RESOLUTION selection
Select FORMULA Type (Math, Radius or other)
Select arguments

DIAL INDICATOR
CALIBRATION STAND

USER MANUAL

Calibration ISO 17025:2017
ISO 9001:2015

SPECIFICATION

Item No

|

Type

|

Calibr.

|

Range

|

Resol

| Micrometer head| Positioning scale| Preset| Go/NoGo| Max/Min| Formula| Timer| Temp comp| Linear corr| Calibr date| Connect. status| Recharge batt| Memory| Wireless| USB| Color Display
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---

Range

|

Accur.

| Non- Rotating
mm| inch| mm| mm| μm
25111026| Horiz| Dial| 0-25| 0-1”|

0,0001

| 25| ±2| | | •| •| •| •| •| •| •| •| •| •| Folders / 2000 val| Long range / HID| USB HID / Update| Touchscreen 1,54”
25111027| •| | •| •| •| •| •| •| •| •| •| •
25111051| 0-50| 0-2”| 50| ±3| | | •| •| •| •| •| •| •| •| •| •
25113025| Vertical|

Dial & Lever

| 0-25| 0-1”| 25| ±2| | | •| •| •| •| •| •| •| •| •| •
25113027| ±2| •| | •| •| •| •| •| •| •| •| •| •
25113050| 0-50| 0-2”| 50| ±2| | | •| •| •| •| •| •| •| •| •| •
25113100| 0-100| 0-4”| ±2| | •| •| •| •| •| •| •| •| •| •| •
25113150| 0-150| 0-8”| ±2| | •| •| •| •| •| •| •| •| •| •| •

TYPES

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-1

TECHNICAL DATA

Parameters|
---|---
LED display| color 2,4 inch 320×240
Indication system| MICS 4.0
Power supply| Rechargeable Li-Pol battery 500 mAh
Charging port| micro-USB
Case material| Aluminium
Wireless data transfer| Long range / HID
USB data transfer| USB HID

  • SWITCH ON DEVICE – button push (1 sec)
  • SWITCH OFF DEVICE – button push (3 sec)/ auto switch off
  • DATA TRANSFER – programming throw menu

3 MODES OF DATA TRANSFER (USB + 2 WIRELESS MODES)

WIRELESS CONNECTION TO MDS app

WIRELESS data transfer to MICROTECH MDS app for Windows, Android, iOS

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-3

WIRELESS HID and USB HID data transfer (like keyboard) direct to any customers app and system

MAIN SCREEN

CONNECTION STATUS

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-4 MICROTECH-25111026-Dial-Indicator-Calibration-
Stand-5

MEMORY

STANDARD or FOLDER system can be activated throw MEMORY menu
For save measuring data to internal device memory touch data area on screen or button push. You can view saved data or send by WIRELESS or USB connection to Windows PC, Android or iOS It’s possible to use Standard or Folders memory modes

MAIN SCREEN on 2D mode

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-6

FUNCTIONS

LIMITS mode GO/NOGO

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-7

PEAK mode MAX/MIN

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-8

TIMER mode

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-9

FORMULA mode

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-10

RESOLUTION selection

DISPLAY settings

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-12

LINEAR error compensation

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-13

TEMP compensation

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-14

WIRELESS data transfer

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-15

USB OTG data transfer

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-16

HUB connection

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-17

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-18

LINK to app’s

RESET to Factory settings

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-20

EXTRA

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-21

MEMORY manager setting

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-22

CALIBRATION date info

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-23

Device INFO

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-24

INDUSTRY 4.0 INSTRUMENTS

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-25

MICROTECH-25111026-Dial-Indicator-Calibration-Stand-26

MICROTECH

innovative measuring instruments
61001, Kharkiv, Ukraine, str. Rustaveli, 39
tel.: +38 (057) 739-03-50
www.microtech.ua
tool@microtech.ua

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals