14-RK10 Ridge ResKey User Guide
- June 13, 2024
- RIDGE
Table of Contents
14-RK10 Ridge ResKey
Product Information
The product is the Ridge ResKey Unit, model 14-RK10. It is a device that is used in conjunction with a receiver (Security Brands 14-REC20 or 14-REC300) to control automatic gates and doors. The unit is powered by two AAA batteries and has an IP44-rating for protection from the elements. It is important to mount the unit in a covered location away from metal objects and anything that may interfere with RF transmission.
Product Usage Instructions
- Unpack the box and ensure that all items are present, except for mounting screws and wall anchors which are not included.
- Remove the single screw from the bottom of the unit and detach it from the mounting plate by pulling it away from the bottom end.
- Take out the screws from the back of the unit housing and carefully remove the back cover to access the battery holders.
- Hold the circuit board in place and insert the AAA batteries into the battery holders, ensuring correct orientation.
- Replace the back cover of the unit and secure it with the screws.
- Install the mounting plate in the desired location using the provided hardware. It can also be done after programming.
- Attach the unit to the mounting plate and secure it with a screw. The mounting plate hook should be slipped into the unit groove before pressing it into place.
Important Safety Information
Automatic gates and doors can cause serious injury or death. Always check
that the gate/door path is clear before operating. Reversing or other safety
devices should always be used.
Note: The following usage instructions pertain to programming the Ridge 2.0 Transceiver 14-REC20, which operates at 433-MHz:
- Press and hold the programming button on the Ridge 2.0 Transceiver for 3 seconds and release. The LED will light up.
- Follow the specific procedures below based on the desired action:
- Pair Keypad Unit with Ridge 2.0 Receiver (14-REC20)
* Enter the Master Code (default is 1251).
* Enter the Sub Mode.
* Enter the Channel (1 for A, 2 for B).
* Add a 433-MHz Access Code by entering the Master Code and the Access Code to be added (4 digits, numbers only).
* Delete a 433-MHz Access Code by entering the Master Code and the Access Code to be deleted (4 digits, numbers only).
* Change the 433-MHz Master Code by entering the Master Code and the New Master Code (4 digits, numbers only).
* Add a 433-MHz Limited-Use Code (Channel A Only) by entering the Master Code and the Code to be added (4 digits, numbers only).
* Delete all 433-MHz Codes by entering the Master Code twice.
2. Follow the same procedure as above, but with different codes, for adding, deleting, and changing 300-MHz Access Codes when using a different receiver (Receiver 300 14-REC300).
Note: It is recommended to use custom DIP switch positions for security reasons. After completing the programming steps, the unit will beep, flash, and emit a good tone to indicate successful completion.
- Unpack the box and make sure you have all the items shown here. (Screwdriver not shown.)
- Remove single screw from bottom of unit and remove unit from mounting plate, pull away from bottom end.
- Remove screws from back of unit housing and carefully remove back cover to gain access to battery holder.
- Hold the circuit board in place and insert the batteries into the battery holder, making sure to place in the correct orientation.
- Replace the back cover of the unit and fasten with screws.
- Install the mounting plate where you want (Hardware not included).(Can be done after programming.) IMPORTANT: This unit is IP44 rated and has some protection from the elements, but it should be mounted in a covered location. Make sure the unit is away from metal objects and anything that interferes or blocks RF transmission.
- Attach unit and fasten with screw.(Can be done after programming.)
433-MHz programming
(Only for the Ridge 2.0 Transceiver 14-REC20)
Pair keypad unit with Ridge 2.0 receiver (14-REC20)
On Ridge 2.0 transceiver, press and hold the programming button for two
seconds and release. LED will light. Complete the procedure below, and the LED
will go out when pairing is successful.
Add 433-MHz access code
Delete 433-MHz access code
Change 433-MHz master code
Add 433-MHz Limited Use Code (Channel A Only)
Delete All 433-MHz Codes
300-MHz programming
(For 300 MHz receivers including the 300 14-REC300 receiver)
IMPORTANT: For security reasons, we recommend using custom DIP switch positions.
Add 300-MHz access code
Delete 300-MHz access code
Change 300-MHz master code
Delete All 300-MHz Codes
Additional information can be found at securitybrandsinc.com/ridge/
NEED HELP
Call 972-474-6390
Email
techsupport@securitybrandsinc.com
We are available Mon–Fri / 8 am–5 pm Central
QSG-14RK10-EN Rev. B (12/2021)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>