marlec HRDi Rutland Controller Remote Display Instruction Manual
- June 12, 2024
- marlec
Table of Contents
Rutland Remote Display
-Model HRDi
Installation and Operation
Introduction
The Rutland Remote 1200 Model is designed for use with the Rutland 1200 Wind Turbine. It enables convenient viewing of the wind generator and PV solar panel charge currents, power, battery Voltages, charging status and accumulated ampere hours of charge to the batteries. It connects to the Rutland 1200 Hybrid Controller via a serial cable and mounting is optional between surface and recessed.
Exploded View
Technical Specifications
Dimensions
Surface Mount: 125x75x50mm Weight: 203g
Recess Mount: 125x75x9mm Weight: 132g Recess Mount Cut Out: 100x62mm
Power Supply: via 3m serial cable supplied. Longer cables available at
www.marlec.co.uk
Mounting—2 Options are Available
Surface mount using the supplied back box. Fix the back box using suitable
screws and fit the display using screws supplied.
Recess mount by discarding the back box and mount directly to a panel with a
100mm x 62mm cut out, using suitable screws .
Fit the screw caps supplied to finish.
Electrical Connection
The power supply for the unit is provided from the WG1200 controller via the serial data cable supplied. Locate the RJ11 sockets on the controller and display unit to connect the 2 devices. The screen will power up. Press any button to illuminate the backlight.
Power Up to Default Screen
Flashing empty battery | Indicates low battery warning |
---|---|
Flashing full battery | Indicates regulating mode |
WG or PV Switched OFF | Coincides with Red illuminated button on controller |
Start Monitoring
Press the WG and PV buttons on the 1200 Hybrid Controller.
Amps and Watts for each charge source are displayed. Any one of the following
is also displayed:
CHG— Charging,
ON— Charge source is on but there is no voltage to start charging.
SBY– Standby, charge source is on but there is insufficient voltage to start
charging.
Note: Any button press on the remote with the backlight off will switch
it on and start it’s countdown timer (default 30s), further button presses
when the backlight is on perform functions as shown below.
Using the Remote Display
Press the DOWN and UP buttons to scroll through the available screens;
WG (Amps) – PV (Amps) – Total (Amps) – Default Screen
The screen can be left to display on any screen, the default screen is
recommended.
When the charge source, WG or PV, has been shutdown, either at the controller or via the Remote, SWITCHED OFF is displayed.
Settings
These are accessed via the ENTER key. The first screen displayed shows the controller serial number.
Press ENTER to view the programming menu. Use the UP and DOWN keys to scroll through and ENTER to select an option. A cursor indicates the option available to select.
Option 1: Charge Sources On/Off
Toggle the UP and DOWN buttons to change between ON and OFF. Press ENTER to
Exit.
Note that when switching WG to OFF the controller enters a soft stall routine,
this slowly applies the stall to decelerate the turbine. During this routine,
the following is displayed and when complete the display returns to the
programming menu.
Option 2: Zero Ah Reading
This function sets to zero all accumulated Ah and elapsed time for both the WG
and PV simultaneously.
To Confirm | Press ENTER |
---|---|
To Exit and return to the programming menu | Press UP or DOWN |
Option 3: Backlight On Time
This function adjusts the length of time the backlight will remain on
following a button press. The default On time duration is 30 seconds.
Adjust the seconds using the UP and DOWN buttons to the desired duration, one press adjusts one second. Press ENTER to save this time to non volatile memory and return to the programming menu.
Other Display Indications
Controller Over Temperature and Over Current
The following displays coincide with the controller LED display for these
conditions. The WG or PV or both will shutdown and display according to the
screen selected as follows:
-
If default screen is selected:
When the condition subsides the normal display is automatically resumed except in the case of PV over current. See below. -
If Current screen is selected the WG and PV screens will display as follows:
Caution: PV Over Current
PV Over Current is a permanent error indicating that a PV array current
exceeding the maximum possible 20A has been connected. The error indication is
only removed following a controller reset. A PV array within permissible
rating should be connected.
Consult the Rutland 1200 installation manual for further advice.
LIMITED WARRANTY
The Marlec Engineering Company Limited Warranty provides free replacement
cover for all defects in parts and workmanship for 24 months from the date of
purchase. Marlec’s obligation in this respect is limited to replacing parts
which have been promptly reported to the seller and are in the seller’s
opinion defective and are so found by Marlec upon inspection. A valid proof of
purchase is required if making a warranty claim.
Defective parts must be returned by prepaid post to the manufacturer Marlec
Engineering Company Limited, Rutland House, Trevithick Road, Corby,
Northamptonshire, NN17 5XY, England, or to an authorised Marlec agent.
This Warranty is void in the event of improper installation, owner neglect,
misuse, damage caused by external factors. This warranty does not extend to
ancillary equipment not supplied by the manufacturer.
No responsibility is assumed for incidental damage. No responsibility is
assumed for consequential damage. No responsibility is assumed for damage
caused by user modification to the product or the use of any unauthorised
components.
Manufactured in the UK by
Marlec Engineering Co Ltd
Distributed in the UK by
Sunshine Solar Ltd
www.sunshinesolar.co.uk
Doc No: SM-351 Iss A 18.07.16
Sunshine Solar Ltd
References
- Marlec - A UK Manufacturer of Battery Charging Off-Grid Wind Turbines
- Solar Panel Products by Sunshine Solar - Sunshine Solar Limited
Read User Manual Online (PDF format)