axema VAKA A45 EM and MIFARE Proximity Reader User Manual
- June 12, 2024
- axema
Table of Contents
axema VAKA A45 EM and MIFARE Proximity Reader![](https://manuals.plus /wp-content/uploads/2023/08/axema-VAKA-A45-EM-and-MIFARE-Proximity-Reader- User-Manual-7.png)
Screw connectors
Connector | Function | B17/B27B28 | B18 |
---|---|---|---|
1-2 | Power supply (connector 1 is positive (+)) | 8-9 | 1-2 |
3-4 | Communication, termination (100Ω) | 10-11 | 3-4 |
Termination and addressing
Unit | A45 | B17, B27 and B28 |
---|---|---|
Termination | Mount the termination jumper | Mount the termination jumper |
Address a B unit (inside reader) | Remove the addressing jumper |
The unit is named in the VAKA software.
Cable
Cable type | Maximum cable length at 24V |
---|
150m
Cat
| 150m
Cat 5/6| 200m
How a UTP Cat 5 should be connected for maximum length.
Maximum cable length between B16/B26 and the reader is 10m. No termination
resistor should be used.
Reading
Present the credential against centre of the reader. A successful reading is
indicated by a red or green LED depending on if the credential do have access
or not.
If a reading not is indicated, the credential lacks compatibility, or that the
MIFARE or EM reading has been disabled. This is set in the in the VAKA
software under Settings, Card/Code, Cards.
Vandal proof cover C811
Mounting
Detach the plastic cover from the A45 and fixate the C811 with the attached
screws. Full stability is obtained after installation when resistance is
provided by the A45 for the vandal protection polycarbonate insert. Without
resistance, the bonding is not strong enough in itself, but should only
facilitate the assembly of the C811.
Please use the screws provided as far as possible as these are customized for
the product’s various installation options.
Tecnical data C811
l 2mm stainless steel
l Mounting screws are includes
l Dimensions: 150x54x19 (HxWxD)
Technical data
Attribute | A45 |
---|---|
Reading distans in optimal conditions | 7 cm with EM, 3 cm with MIFARE |
Power supply | From door controller |
IP-rating | IP44 |
IP rating | IK06 (IK08 with C811) |
Temperature range | -30° to +55C° |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>