Product Information

The DDSU666 Energy Meter is a device that can achieve energy management together with the Solar  single phase inverter. It is designed for use in a 80A system or below, and is capable of measuring the import, export, and total power and energy. The meter is equipped with a single phase input port and an RS485 port for communication.

Specifications

  • Model DDSU666
  • Frequency 60Hz
  • Voltage 230V
  • Current Type 0.25-5(80)A Direct connection

Notes and Safety

cut off all power of inverter before installation  Wait for 5 minutes after power off.
donger of high voltage  Danger to life due to high voltage of this machine.

Introduction

DDSU666 Meter can achieve energy management together  with solar  single phase inverter. It applies to 80A system on  below, measure the import, export and total power and energy.

Terminals and DimensionSo lax- Power- DDSU666 Energy- Meter-
fig-2

1,2,3 Single phase input port
24,25 RS485 port

Only authorized personnel is allowed to seethe  connection.

Performance and Specie  cation

Installation

Mounting
DDSU666 meter is designed for indoor installation ,It could be installed on the wall or other place indoor.So lax- Power-DDSU666-Energ- Meter-User-
fig

Wiring diagram
cable size  5AWG or ≤16mm²

Direct access to the instrument

Communication cable size 17~23AWG or 0.25~1mm²


Wiring Connection

Step 1
RS485 terminal connection

  1. Prepare a communication cable
  2. Trip the insulation from the communication cable.
  3. Connect the meter communication cable and inverter with reference to the inverter manual
  4. Connect the other end of the communication  cable to the port 24 and 25 of meter. See the guru for the connection.

PS The color of the communication cable in the figure is for reference only. Please refer to the  actual situation for the specific connection.

Step 2
Current wire connection

  1. Insert the L wires to the ports 1 and 3 of the meter  respectively. Connect port 1 with Grid terminal and port  3 with Load terminal.
  2. Connect N wires with the port 2 of the meter.

LCD description

  1. Meaning that the meter is showing the voltage, the unit is ‘V’

  2. Meaning that the meter is showing the current, the unit is ‘A’

  3. Meaning that the meter is showing   power, the unit is ‘W

  4. Meaning that the meter is showing the   active energy, the A

  5. Meaning that the meter is showing the communication protocol

  6. Meaning that the current 645 address is 100000000011

  7. Meaning that the current 645 address is 100000000011

  8. Meaning that the baud rate is 24

Exclusion of liability
Warranty claims are excluded for direct or indirect damage  due to

  1. Use of unit in ways not intended, improper installation and  installation that does not comply with standards, improper  operation and unauthorized m cation to the units or repair  attempt.
  2. Without warranty card and serial number.
  3. Operating the units with defective protective equipment.
  4. Nuance  of deign  objects and force majeure.
  5. Inadequate ventilation.
  6.  Violate relevant safety regulations

To register your So lax  product, please mail this warranty card to:

SolaX Power Network Technology (Zhejiang) Co., Ltd.
ADD. No.288 shizhu Road, Tonglu Economic Zone,
Tonglu City, Zhejiang Province, China.
Tel. +86 571 56260011
FAX +86 571 56075753
EMAIL service@solaxpower.com

WEB www.solaxpower.com 

Online warranty registration is available at
http://www.solaxpower.com

Warranty Registration Form

Name
Product Serial Number
Date of Commissioning Installation Company Name
Phone Number

Email
Address
Country
Zip Code

Product Serial Number
Date of Commissioning
Installation Company Name

Date of Delivery
Signature

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SOLAX POWER User Manuals

Related Manuals