The product is a pump designed for water gardening purposes. It is available in three models: 472, 473, and 474. The pump operates on a voltage of 220-230V and a frequency of 50Hz. Each model has a different power rating and flow rate. Model 472 has a power of 52W  and a flow rate of 5000 liters per hour. Model 473 has a power of  70W and a flow rate of 6500 liters per hour. Model 474 has a power  of 80W and a flow rate of 8500 liters per hour. The pump is suitable for use with ponds, filters, waterfalls, and fountains.

IMPORTANT SAFETY INSTRUCTIONS

WARNING  To guard against  injury or death, basic safety precautions should be  observed, including the following .

READAND FOLLOW ALL SAFETY INSTRUCTIONS

  •  Register your purchase on-line  at www.closerpets.com (segue ante overleaf).
  • All electrical work must be carried out  by a competent electrician.
  • Check that the voltage label on the motor conforms with your supply voltage.
  • The pump MUST be wired into a  ground fault circuit interrupter  (G.F.C.I.) maximum 30mA and a3 AMP (maximum) fuse.
  • Connection to the power supply  should be made through a double pole switched enclosure with minimum 1/8″  (3mm) contact separation in all poles.
  • This appliance must be earthed. It  is essential that all connections are  securely made using the following code.
  • Brown
  • Live
  • Blue
  • Neutral
  • Green
  • Yellow
  • Earth
  • Do not carry or pull the pump using the supply cord.
  • Disconnect electrical supply from  all appliances in the pond including  pumps and filters before contact with the pond water or pump.
  •  Maximum operation depths 5ft(1.5m).
  • Do not use with water above 35℃.
  • Closely supervise children when near  to pond or pond equipment.
  • Use pump only for ponds – do not use  pump in connection with swimming  pools, showers, etc.
  •  Use conduit approved by your electricity authority to protect supply  cord where damage from gardening equipment, children and animals may occur.
  • Discard pump if motor shows visual defects (e.g. cracks or swelling).
  • The supply cord of this appliance  cannot be replaced; if the cord is damaged the appliance should be discarded.
  •  Do not allow the pump to run dry.
  •  Do not operate the pump in freezing conditions. Remove, disassemble  and dry pump if there is a risk of pump being frozen.
  •  This pump is provided with a thermal cut-out switch that temporarily  switches off the pump in case of  overheating. The pump may restart  when it has cooled.
    SAVE THESEINSTRUCTIONS

Pond Pump   Instructions
IMPORTANT READ BEFORE USEClose- Pets472,-473,-474 -Pond Pump-
fig1

PUMP INSTALLATION

Ideally and for convenience the pump should be positioned within reach of the side of the pond on a solid platform (e.g. paving slabs).  The pump must be at least 200mm (8″) below water level to avoid problems of freezing and  low water levels in summer. All electrical work should be completed by qualified electrician.

Waterfall/Filter Only
For use with a pond filter you will often get  improved results with the pump sited at the  opposite end of the pond to the filter return.  The pump comes as standard with pond-life  friendly slots to help protect spawning life. In  some ponds this may not be necessary and you may want to modify the pump to enable solids handling as below. The pump may be connected to a waterfall or filter using 19mm (3/4″), 25mm (1″) or 32mm    (11/4″) bore hose. For maximum flow use 32mm (11/4″) hose connected directly to  the hose adaptor on the rotor cover.  The rotor assembly can be rotated through  90° as required by twisting the front end of the pump.

Fountain (and Waterfall/Filter)
Insert fountain components as instructed IN Fountain  Kit.

MAINTENANCE

TROUBLESHOOTING IMPORTANT SAFETY INSTRUCTIONS

  • Disconnect electrical supply from  removing from pond or contacting pond water.
  • Do not carry or pull the pump by the cable.

When flow from your pump is noticeably  reduced or fountain display has deteriorated

  1. Remove strainer cover by squeezing sides and pulling off.
  2.  Clean cover and remove any weed or blockage around pump inlet rotor inlet.
  3. If you are using a fountain, remove and clean fountain  head in water with a brush.

Reassemble. If flow is still poor check to see if   outlet pipe has become kinked or blocked.

If flow is stopped

  1. Disconnect power
  2. Remove cover and check for free rotation/  breakage of rotor.
  3. If rotor will not turn or is broken, remove and clean replace if broken or worn.  If in doubt please contact Closer Pets Customer Service.
  4. Reassemble in reverse order after careful  cleaning of all components.
  5. Replace the pump in water before reconnecting  power to start pump. If pump does not start or stops again please contact Closer Petco’s  Tomer  Service.
Model Voltage Power (W) Flow Rate Lift (M)
472 220-230V 50HZ 52 5000 L/H 4.0
473 220-230V 50HZ 70 6500 L/H 5.0
474 220-230V 50HZ 80 8500 L/H 5.5

www.closerpets.com

SPARES

Pump Model Spares Kit Code Product
472 485 5000 Intermediate Pump Service Kit
473 486 7000 Intermediate Pump Service Kit
474 487 9000 Intermediate Pump Service Kit

GUARANTEE

We offer a 1-year standard warranty. However, if you register your product at www.closerpets.  com pages/product-registration within 14 days of your purchase you get an additional 2-years warranty and Pet Mate Ltd. will guarantee your product for a period of 3 years from the date of  purchase. If you do not have access to a computer, please send details of your purchase with a copy of the receipt along with your name and address, and our Customer Services team will handle this for you. Please get  in touch with Closer Pets Customer Services if you have a problem with your purchase. The guarantee is here to protect you if any defect arises due to  faulty materials or manufacture. Any defective items will be repaired  or replaced free of charge by Pet Mate Ltd, provided the defect has not been caused by neglect, misuse conormal wear and tear. Your statutory rights are not affected. To get started, register now by scanning the QR

code or by following the link here: www.closerpets.com/pages/product- registration
IMPORTANT

your country. UK/EU: Refer to Terms and Conditions section EU Waste Electrical and Electronic Equipment (WEEE) Directive on www.closerpets.com for more information. Hereby, Pet Mate Ltd., declares that this product is in compliance with the essential requirements and other relevant provisions of EU and UK Directives. All Declarations of  Conformity (Dock ) may be viewed at www.closerpets.com/pages/eu-doc. Designed  and Manufactured by Pet Mate Ltd: Lyon Road, Horsham, Surrey KT12 3PU, UK Imported to the EU by Closer Pets BV Newtonian  115, 3584 BH Utrecht, The Netherlands Imported to North America by Ani Mate: 104A Longview Street.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals