JET AFS-400 Air Filtration System Instruction Manual
- June 12, 2024
- JET
Table of Contents
- JET AFS-400 Air Filtration System
- Product Information
- Product Usage Instructions
- CE-Conformity Declaration
- Warranty
- Safety
- Machine specifications
- Assembly and start up
- Machine operation
- Maintenance and inspection
- Trouble shooting
- Available accessories
- Environmental protection
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
JET AFS-400 Air Filtration System
Product Information
- Product Name: AFS-400 Air Filtration System
- Brand: Tool France SARL
- Model Number: AFS-400-M (708612M)
- Year of Manufacture: 2019
Compliance:
- Complies with the 2006/42/EC Machinery Directive
- Meets the requirements of EN ISO 12100:2010 and EN 61029-1:2009+A11/2010
Warranty:
- Tool France SARL guarantees that the supplied product(s) is/are free from material defects and manufacturing faults.
- Warranty does not cover defects caused by incorrect use, carelessness, accidents, repairs, inadequate maintenance or cleaning, and normal wear and tear.
- Further details on warranty can be found in the General Terms and Conditions (GTC) that are an integral part of the contract.
Product Usage Instructions
Safety Precautions
- Read and understand the entire instruction manual before attempting assembly or operation of the air cleaner.
- Keep the operating instruction close to the product, protected from dirt and humidity, and pass it over to the new owner if you part with the tool.
- The air cleaner is designed for the filtration of air-borne wood dust only. Any other application is not permitted without consulting the manufacturer.
- Do not use the product in wet or humid environments.
- Do not use the appliance in places with a risk of explosion.
- Ensure compliance with the operating and maintenance instructions given in this manual.
- The air cleaner should only be operated by persons familiar with its operation an maintenance, and who are aware of its hazards.
- Observe the required minimum age for operation.
- The air cleaner must only be used in a technically perfect condition.
- Before connecting the air cleaner to electric power, ensure that all safety mechanisms and covers are properly mounted.
- Additionally, observe the generally recognized technical rules concerning dust collection on woodworking machines.
Assembly and Start-up
- Follow the assembly instructions provided in the manual.
- Install the air cleaner according to the specified guidelines.
- Connect the air cleaner to the mains power supply following the instructions.
Machine Operation
- Familiarize yourself with the remote control operation of the air cleaner.
- Ensure proper overload protection during operation.
Maintenance and Inspection
Follow the instructions for changing filters as outlined in the manual.
Troubleshooting
Refer to the troubleshooting section of the manual for guidance on resolving
any issues.
Available Accessories
Check the list of available accessories for the air filtration system.
Environmental Protection
Observe and follow environmental protection guidelines related to the use and
disposal of the product.
CE-Conformity Declaration
Product
Air filtration system
AFS-400-M
(708612M)
Brand
JET
Manufacturer
TOOL FRANCE SARL, 9 Rue des Pyrénées, 91090 Lisses France
We hereby declare that this product complies with the regulations
- 2006/42/EC Machinery Directive
- 2014/30/EU electromagnetic compatibility
- designed in consideration of the standards
EN ISO 12100:2010
EN 61029-1:2009+A11/2010
EN 61000-6-1:2007
EN 61000-6-3:2007
Responsible for the Documentation
TOOL France SARL
Dear Customer,
Many thanks for the confidence you have shown in us with the purchase of your
new JET-machine. This manual has been prepared for the owner and operators of
a JET AFS-400 air filtration system to promote safety during installation,
operation and maintenance procedures. Please read and understand the
information contained in these operating instructions and the accompanying
documents. To obtain maximum life and efficiency from your air cleaner, and to
use it safely, read this manual thoroughly and follow instructions carefully.
Declaration of conformity
On our own responsibility we hereby declare that this product complies with
the regulations and standards listed on page 2.
Warranty
Tool France SARL guarantees that the supplied product(s) is/are free from
material defects and manufacturing faults.
This warranty does not cover any defects which are caused, either directly or
indirectly, by incorrect use, carelessness, damage due to accidents, repairs
or inadequate maintenance or cleaning as well as normal wear and tear.
Further details on warranty (e.g. warranty period) can be found in the General
Terms and Conditions (GTC) that are an integral part of the contract. These
GTC may be viewed on the website of your dealer or sent to you upon request.
Tool France SARL reserves the right to make changes to the product and
accessories at any time.
Safety
Authorized use
- This air cleaner is designed for the filtration of air borne wood dust only. Any other application is not permitted and may be carried out in specific cases only after consulting with the manufacturer.
- The product is not suitable for use in wet or humid environment.
- Don’t use appliance in places with a risk of explosion.
- Don’t use appliance at temperatures below 0°C.
- The proper use also includes compliance with the operating and maintenance instructions given in this manual.
- The air cleaner must be operated only by persons familiar with its operation and maintenance and who are familiar with its hazards.
- The required minimum age must be observed.
- The air cleaner must only be used in a technically perfect condition.
- Before connecting the air cleaner to electric power, all safety mechanisms and covers must be mounted.
- In addition to the safety requirements contained in these operating instructions and your country’s applicable regulations, you should observe the generally recognized technical rules concerning the dust collection on woodworking machines.
- Any other use exceeds authorization.
- In the event of unauthorized use of the product, the manufacturer renounces all liability and the responsibility is transferred exclusively to the operator.
General safety notes
- Read and understand the entire instruction manual before attempting assembly or operation of the air cleaner.
- Keep this operating instruction close by the product, protected from dirt and humidity, and pass it over to the new owner if you part with the tool.
- No changes to the air cleaner may be made.
- Daily inspect the function and existence of the safety appliances before you start the air cleaner.
- Do not attempt operation in this case, protect the air cleaner by unplugging the power cord.
- Always disconnect the air cleaner from the power source (unplug) before servicing or changing filters.
- Never reach into the machine while it is operating or running down.
- Replace contaminated filters.
- Clogged filters will reduce the amount of air circulation.
- During the changing or cleaning of the filters it’s necessary to use a mask (mask with filtration).
- The machine is designed to operate in closed rooms and can be placed on a stable and levelled surface, or can be wall or ceiling mounted.
- If ceiling mounted, the bottom of the air cleaner must be at least 2,1m above the floor.
- Mounts must be anchored to building structure, which will support a minimum of 30 kg.
- Never mount to surfaces such as dry wall or false ceiling grids, etc.
- Make sure that the power cord does not impede work and cause people to trip.
- Do not operate the machine under the influence of drugs, alcohol or any medication. Be aware that medication can change your behaviour.
- Never leave a running machine unattended. Before you leave the workplace switch off the unit.
- Keep children and visitors a safe distance from the work area.
- Do not operate the electric tool near inflammable liquids or gases.
- Observe the fire fighting and fire alert options, for example the fire extinguisher operation and place.
- Do not use the air cleaner in a dump environment and do not expose it to rain.
- Never duct a machine directly into the air cleaner.
- Do not use this equipment to filter volatile fumes or smoke.
- Wood dust is explosive and can also represent a risk to health. Dust form some tropical woods in particular, and from hardwoods like beach and oak, is classified as a carcinogenic substance.
- The air filtration system will support, but cannot subsidise the application of a suitable dust extraction device for your woodworking machines.
- Do not stand on or hang on the air cleaner.
- Connection and repair work on the electrical installation may be carried out by a qualified electrician only.
- Have a damaged or worn power cord replaced immediately.
Remaining hazards
- When using the unit according to regulations some remaining hazards may still exist.
- Woodworking dust can be a health hazard. The air filtration system will support but cannot subsidise the application of a suitable dust extraction device for your woodworking machines.
- The use of incorrect mains supply or a damaged power cord can lead to injuries caused by electricity.
Machine specifications
Technical data
- Air volume flow 8, 10, 11.5 m³/min
- Programmable timer 1, 2, 4 hours
- Replacement outer filter 5 micron
- Washable inner filter 1 micron
- Overall (LxWxH) 520x440x265mm
- Net weight 14 kg
- Mains 1~230V, PE, 50Hz
- Output power 0,1 kW (0,13HP) S1
- Reference current 1 A
- Extension cords (H05RN-F): 3×1,5mm²
- Installation fuse protection 10A
- Protection class I
Noise emission
Acoustic pressure level (according to EN ISO 11202):
- low speed LpA 51 dB(A)
- medium speed LpA 57 dB/A)
- high speed LpA 61 dB(A)
The specified values are emission levels and are not necessarily to be seen as safe operating levels. This information is intended to allow the user to make a better estimation of the hazards and risks involved.
Content of delivery
- Air filtration unit
- Infrared remote control unit
- AA batteries
- Eye-bolts and nuts
- Mounting hook screws
- Chain sections
- Operating manual
- Spare parts list
Assembly and start up
Assembly
If you notice transport damage while unpacking, notify your supplier
immediately. Do not operate the unit!
Remove all packing from the inside of the unit by removing the outer filter
and the inner filters.
Install the supplied AA batteries into the remote control unit.
Dispose of the packing in an environmentally friendly manner.
Installation
This unit will work best if it is located away from corners, and
heating/cooling vents.
This unit is specifically designed to circulate air and filter non-metallic
dust, which is generated throughout the work area.
The air cleaner is designed to operate in closed rooms in a horizontal
position.
-
Placed on levelled surface:
Place the unit on a stable and levelled surface. -
Hanging from ceiling:
Remove four screws (A, Fig 2) from the cabinet top.
Fig 2
Install four eyebolts (B) and tighten hex nuts (C).
Drill holes and securely mount the four provided hook screws (Y) in the
ceiling.
Note:
- Mounting hook screws must be anchored to building structure (X), which will support a minimum of 30 kg.
- Never mount to surfaces such as dry wall or false ceiling grids, etc.
- Use the provided sections of chain (Z) for mounting the air filtration system.
- The bottom of the air cleaner must be at least 2,1m above the floor.
Mains connection
- Mains connection and any extension cords used must comply with applicable regulations.
- The mains voltage must comply with the information on the machine licence plate.
- The mains connection must have a 10 A surge-proof fuse.
- Only use extension cords marked H05RN-F, with wires 1,5mm2 or more.
- The total length of cords may not exceed 25 Meter.
- Connections and repairs to the electrical equipment may only be carried out by qualified electricians.
Machine operation
Remote control operation
The TIME button (F, Fig 3) controls the timer setting.
The air filtration system will operate for either 1, 2 or 4 hours before it
shuts off.
The ON SPEED button (E) turns unit on and controls the air volume flow. You
can choose between low, medium and high.
The OFF button (D) turns the unit off.
There are also manual ON / OFF buttons on the backside of the unit (Fig 4).
Overload protection
In case of overload, the motor control unit switches the unit off. Wait 5
minutes to cool down and then re-start the unit.
The fuse (G, Fig 5) protects the electrical system in case of high Amp-
overload.
Maintenance and inspection
General notes:
- Maintenance, cleaning and repair work may only be carried out after the machine is protected against accidental starting by pulling the mains plug.
- Inspect the proper function of the air filtration system daily.
- Replace clogged filters.
- Clean the unit regularly.
- Defective safety devices must be replaced immediately.
- Repair and maintenance work on the electrical system may only be carried out by a qualified electrician.
Changing Filters
Disconnect the machine from the power source.
During the changing or cleaning of the filters it’s necessary to use a mask
(mask with filtration).
There are two filters that need to be cleaned or changed.
The outer filter can easily be removed by disengaging the two clips (Fig 6).
Now you can simply pull the filter out, or carefully use a screwdriver to pop
the filter out.
Make sure the filter is inserted facing the proper direction (JET-Logo
visible)
The outer filter should be replaced depending on the amount of usage and the
environment of your shop.
The inner filter can be pulled out of the unit (Fig 7).
The inner filter can be blown out with air (to be done outside of building only!), or can be washed out.
Trouble shooting
Unit doesn’t start
- No electricity- check mains and fuse.
- Defective switch, motor or cord- consult an electrician.
- Motor overload protection has reacted-Wait 5 minutes to cool down, re-start the unit.
- Overload fuse has blown- Change the fuse.
Remote control doesn’t work
- Batteries are down- replace AA Batteries.
- Infrared light transmission blocked- visual contact must be given.
- Defective remote control or sensor- consult an electrician.
Air flow too weak
- Clogged outer filter-Replace filter.
- Clogged inner filter-
- Blow out with air or wash filter.
Available accessories
-
Stock number 710621
Inner filter (1 Micron, washable). -
Stock number 710622
Electrostatic outer filter (5 Micron, replacement filter)
Environmental protection
Protect the environment.
Your appliance contains valuable materials which can be recovered or recycled.
Please leave it at a specialized institution. This symbol indicates separate
collection for electrical and electronic equipment required under the WEEE
Directive (Directive 2012/19/EC) and is effective only within the European
Union.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>