BROAN AR80MB Roomside Series 80 CFM Decorative Ventilation Fan Installation Guide

June 12, 2024
Broan

BROAN AR80MB Roomside Series 80 CFM Decorative Ventilation Fan

Product Information:

ROOMSIDE SERIES AR80MB

The ROOMSIDE SERIES AR80MB is a fan and light combination unit designed for installation in residential spaces. It provides quiet and efficient operation, long life, and an attractive appearance. The fan features a permanently lubricated motor that never needs oiling. The unit is equipped with a blower assembly that includes the motor and impeller.

This product is suitable for use in various rooms of the house, excluding cooking areas. It is important to ensure proper installation and maintenance for optimal performance.

Cleaning & Maintenance

To maintain the performance of the fan, it is recommended to remove the grille and vacuum the interior of the unit using the dusting brush attachment. The motor does not require oiling, but if excessive or unusual noises are heard from the motor bearings, it is advisable to replace the blower assembly.

Operation

The fan and light can be operated using separate switches. An on/off switch or speed control can be used to operate the fan, while a separate switch is needed for the light. Refer to the Wiring Diagram section for detailed instructions.

Safety

It is essential to follow safety precautions during installation and use to reduce the risk of fire, electric shock, or injury to persons.

Installation

  • Step 1: Start by removing the blower and all packing material from the fan housing.
  • Step 2: If required, attach a pair of flanges to the housing by snapping both flange pieces under the rolled-over edge of the housing on all four sides.
  • Step 3: Attach grille brackets to the housing.
  • Step 4: Mount the housing to the ceiling structure.
  • Step 5: Connect a 4-inch round duct to the housing for proper ventilation.
  • Step 6: Attach the damper/duct connector to the fan housing by pushing it through the opening from the inside of the housing. Engage the tabs and secure with the provided screw.
  • Step 7: Install the blower by securing it with the two screws provided and plugging it into the black receptacle.
  • Step 8: Connect the wiring by using an appropriate UL approved connector to connect the power cable to the housing. Follow the wiring connections as shown in the Wiring Diagram section. Reinstall the wiring panel and secure it with the screw from the parts bag.

Note: For retrofit installations, refer to page 5 of the user manual for specific instructions.

For further information, warranty details, or to order service parts, please visit our website and enter the model number in the Model Search field.

Register this product at broan-nutone.com or broan-nutone.ca. For Warranty Statement, or to order Service Parts: go to the appropriate website and type the model number in the “Model Search” field.
Installer: Leave this manual with the homeowner.

READ AND SAVE THESE INSTRUCTIONS

WARNING
To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  • Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
  • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • Ducted fans must always be vented to the outdoors.
  • This unit must be grounded.

CAUTION

  • For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  • For installation in flat ceilings only.
  • To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
  • Please read specification label on product for further information and requirements.

CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance – remove grille and vacuum interior of unit with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).

OPERATION
Use an on/off switch or speed control to operate this fan and a separate switch to operate the light.
See “Wiring Diagram” for details.

ALL INSTALLATIONS

Start here.

IMPORTANT – The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.

OPTION – To mount housing anywhere between ceiling framing: Use optional Hanger Bar Kit (sold separately from local distributors or website). Follow mounting instructions included with kit.

  1. Remove blower and all packing material from fan housing.

  2. Remove wiring panel from fan housing (if already installed).

  3. A pair of flanges may be attached to housing if desired or required.
    Snap both flange pieces under rolled-over edge of housing (all four sides).

  4. Attach grille brackets to housing.

NEW CONSTRUCTION
For Retrofit Installation

  1. Mount housing to ceiling structure.
    Make sure bottom of housing will be flush with finished ceiling.
    For proper location when using ½” ceiling material: Bend out housing tabs to fit against bottom of structure.
    Secure housing through mounting ears with appropriate fasteners (not included).
    If mounting housing to I-joist, use wood blocking as shown.

  2. Attach damper/duct connector to fan housing.
    Push connector through opening from inside of housing. Engage tabs and secure with screw from parts bag.

  3. Connect 4-in. round duct.

  4. Connect wiring.
    Connect power cable to housing with appropriate UL approved connector (not included). Make wiring connections as shown in “Wiring Diagram” section. Re- install wiring panel and secure with screw from parts bag.

  5. Install blower.
    Re-install blower. Secure blower with (2) screws from parts bag and plug blower into black receptacle.

BROAN AR80MB Roomside Series 80 CFM Decorative Ventilation Fan-
fig11

  1. Finish ceiling, then install grille.
    NOTE: The MOUNTING PLATE and GRILLE PAN need to be disassembled before installing.
    Attach MOUNTING PLATE to housing with (2) SCREWS, using the GRILLE BRACKETS installed in step 4. The MOUNTING PLATE hole that does not have a triangle next to it must be aligned with the LIGHT PLUG.
    Connect LIGHT PLUG to receptacle in corner of housing.
    Secure GRILLE PAN to MOUNTING PLATE USING (3) GRILLE PAN MOUNTING SCREWS.
    Line up GLASS SHADE with GRILLE PAN openings and rotate GLASS SHADE clockwise to secure it to GRILLE PAN.

BROAN AR80MB Roomside Series 80 CFM Decorative Ventilation Fan-
fig12

RETROFIT

Remove old fan.
Enlarge ceiling opening (if necessary) to 9¾” (parallel to joist) by 10½” (perpendicular to joist). Leave ductwork and wiring in place.

Fold mounting ears flat against housing.

Connect wiring.
Connect power cable to housing with appropriate
UL approved connector (not included). Make wiring connections as shown in “Wiring Diagram” section. Re-install wiring panel and secure with screw from parts bag.

Mount fan to ceiling structure.
Mount housing to ceiling structure with standard drywall or wood screws (not included) in locations shown.
*Center hole optional.

Connect 4-in. round duct.

  1. Pull existing ducting through housing discharge opening.
  2. Attach and tape ducting to duct connector.
  3. Push connector/ducting back through opening.
  4. Engage tabs and secure with screw from parts bag.

Install blower. Finish ceiling, then install grille.

WIRING DIAGRAM

BROAN AR80MB Roomside Series 80 CFM Decorative Ventilation Fan-
fig18

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Broan User Manuals

Related Manuals