CASPR Compact Portable Air and Surface Purification
Product Information
The CASPR Compact is a compact and efficient air purifier designed to provide years of trouble-free service when properly maintained. It is equipped with a remote control for easy operation and offers different modes for air purification. The unit can be purchased from authorized distributors or directly from CASPR Group.
Product Usage Instructions
- Place the CASPR Compact on a counter top or shelf, ensuring there is enough space in front and back of the unit for air to flow through.
- Plug the unit in using the included power cable.
- Insert the battery inside the remote control.
- Power on the unit using the remote control or by pressing the display screen.
- Set the fan to a comfortable sound level.
- Leave the CASPR Compact in NORMAL Mode, which is the standard mode for occupied rooms. The screen will read PCO or NCC depending on the purchase date.
- For higher disinfection levels when the space is occupied, use the AWAY MODE. Pressing the Away Mode key will start a timer (2 to 8 hours). The CASPR Compact will automatically switch back to Standard Mode when the timer ends or when you push NORMAL Mode again.
- NEVER USE AWAY MODE WHEN THE ROOM IS OCCUPIED.
Warnings
- Never operate the unit near a heat source, open flame, or flammable/combustible fluids.
- Do not operate the unit unless all parts (including Cell, Purification Plate, Rear Filter Assembly, and Rear Cover) are properly installed.
- Directly viewing the lamp inside the unit for an extended period (longer than 20 min.) may result in eye damage.
- When using AWAY Mode, never adjust the setting to exceed the square footage of the ventilated space being treated. The ventilation system from the room should provide a minimum of three air exchanges per hour for this mode to be effective.
- Do not use AWAY MODE in occupied spaces. Short-term exposure to ozone levels exceeding 0.5 ppm can cause temporary adverse reactions, especially in pets, children, the elderly, and individuals with preexisting conditions such as asthma, heart conditions, or high blood pressure.
- Before cleaning, disassembling, reassembling, or servicing the unit, make sure it is powered OFF and the power cord is disconnected.
Note: Some CASPR Compact Versions (CASPR COMPACT-CA) do not include purification plates. These versions will remain in Normal PCO/NCC Mode regardless of what mode is displayed on the screen, and can always be used in occupied spaces. If you are unsure of which version you own, please contact your distributor.
Welcome to CASPR COMPACT.
CASPR COMPACT is designed to provide years of trouble-free service when it is
properly maintained. Even when properly cared for, some parts of your CASPR
COMPACT will need to be replaced periodically. Replacement parts can be
purchased from your authorized distributor or directly from CASPR Group.
(www.casprgroup.com)
Quickstart
-
Place CASPR COMPACT on a counter top or shelf approximately 6-feet or higher, never on the floor. Ensure there is room in front and back of the unit for air to flow through.
-
Plug the unit in with the included power cable.
-
Insert the CR2025 battery inside the remote control.
-
Power on with the remote or by pressing the display screen then set the fan to a comfortable sound level. Leave the CASPR COMPACT in NORMAL Mode – Screen will read PCO or NCC (depending on the purchase date). This is the standard mode for occupied rooms. High mode is used for high burst of disinfection and should not be used for more than one hour in any occupied space.
Note: Some CASPR Compact Versions (CASPR COMPACT-CA) do not include purification plates. These versions will remain in Normal PCO/NCC Mode regardless of what mode is displayed on screen, and can always be used in occupied spaces. If you are unsure of which version you own, please contact your distributor. -
Only use the AWAY MODE for a higher level of disinfection when space is NOT occupied. Pressing the Away Mode key will start a timer (2 to 8 hours). The CASPR COMPACT will go back to Standard Mode when the timer ends or when you push NORMAL Mode again.
Warnings
Review this list before using or performing any maintenance or cleaning of
your unit.
- WARNING: Never operate unit near a heat source, open flame or flammable/combustible fluids.
- WARNING: Do not operate unit unless all parts (including Cell, Purification Plate, Rear Filter Assembly and Rear Cover) are properly installed.
- CAUTION: Directly viewing the lamp inside unit for an extended period (longer than 20 min.) may result in eye damage.
- CAUTION: When using AWAY Mode, never adjust setting to exceed square footage of ventilated space being treated. To use this mode, the ventilation system from the room should provide a minimum of three air exchanges per hour.
- CAUTION: Do not use AWAY MODE in occupied spaces. Short term exposure to ozone levels exceeding 0.5 ppm can cause temporary adverse reactions, including irritation in the eyes, nose and throat, shortness of breath, chest pain, and wheezing. Pets, children, the elderly, and individuals with preexisting conditions such as asthma, heart conditions, or high blood pressure are especially at risk.
- CAUTION: Unit should be powered OFF and Power Cord should be disconnected when Cleaning/Disassembling/ Reassembling/Servicing.
Set up and Operation
(Initial Setup)
Ideal Placement
- Make sure the location you choose is as close to an air supply duct as possible and as far away from the HVAC air return duct as possible. This will ensure that the oxidizing molecules produced by the CASPR COMPACT are optimally circulated.
- Each CASPR COMPACT can effectively treat 1,500 sq feet of space as long as there is air circulation in the space. Be sure doors are open in areas that you wish to treat.
- To ensure the unit works properly, there should be as much space as possible in front of your CASPR COMPACT so that It can efficiently process the air in the area.
- Place CASPR COMPACT on a shelf or counter top.
Never place an operating unit on the floor.
Operating CASPR COMPACT
- Connect the Power Cord to the Power Adapter and the Power Adapter Plug into the unit. (Check to be sure your power supply is properly assembled. The Power Cord should be inserted far enough into the Power Adapter so that a space of only about 1/8 in. is left between the widest part of the power cord and the edge of the Power Adapter).
- Insert the Power Plug into the wall outlet.
- Turn on the unit by pressing the POWER button and set it to NORMAL mode. The screen will read PCO or NCC (Depending on the purchase date). This is the optimal setting for running CASPR COMPACT continuously in your office or home. Adjust the fan to a comfortable sound level using the up and down buttons next to the display.
- CASPR COMPACT comes with a remote control, and one CR2025 battery, for easier operation when the unit is placed on a high shelf, approximately 6-feet or higher.
Note: Some CASPR Compact Versions (CASPR COMPACT-CA) do not include purification plates. These versions will remain in Normal PCO/NCC Mode regardless of what mode is displayed on screen, and can always be used in occupied spaces. If you are unsure of which version you own, please contact your distributor.
Operating Modes
Normal: Continual Usage: 24/7; High: Set Accurate Square Footage; Away: Limit to Unoccupied Spaces ONLY
-
When to use NORMAL Mode
NORMAL mode is the default mode for continually running your CASPR COMPACT. -
When to use HIGH Mode
- High mode is used for burst purification, removing pollutants like smoke or other significant odors. Do not run HIGH mode for more than one hour with occupants in the room.
- When CASPR COMPACT is set to HIGH Mode the display will ask you to set the square footage. Press the PURIFIER button up or down to set the square footage of the room for the most effective treatment.
-
When to use SLEEP Mode
Access SLEEP mode on your remote control. Activating this setting will dim the display screen settings. -
When to use AWAY Mode
- AWAY Mode generates ozone for deep cleaning an area. This mode can be used for removing smoke, cooking odors, mold spores, viruses and bacteria. AWAY mode runs on a timer and once it completes the cycle, it returns to Normal Mode.
- Set AWAY Mode by pressing the AWAY Mode button. Each time you press the button it will increase the time of the cycle from 2:00, 4:00, 6:00 or 8:00 hours.
- If AWAY Mode is running when you enter the room, push the NORMAL/HIGH button once to return to NORMAL Mode.
NEVER USE AWAY MODE IN OCCUPIED SPACES INCLUDING SPACES OCCUPIED BY PETS.
Note: Some CASPR Compact Versions (CASPR COMPACT-CA) do not include purification plates. These versions will remain in Normal PCO/NCC Mode regardless of what mode is displayed on screen, and can always be used in occupied spaces. If you are unsure of which version you own, please contact your distributor.
Diagrams
Unit
- **Front of Unit
**
1. Ionization Needle
2. Front Grille
3. Control Panel
- **Rear of unit
**
1. Rear Cover Screw
2. Rear Cover Grooves
3. Power Adapter Inlet
- **Side of Unit
**
1. Rear Cover
2. Unit Rear
3. Unit Front
- Rear of Unit
(Rear Cover Removed)
1. Filter Assembly
- Rear of Unit
(Filter Assembly Removed)
1. NCC Cell
2. Cell Nuts
3. Cell Connector
4. Purification Plate*
- **Power Supply
**
1. Power Cord
2. Power Cord Plug
3. Power Adapter
4. Power Adapter Plug
Controls
Remote
- Power Button
- Toggle Switch (Normal PCO or NCC/High Mode)
- Unit control (whether in ft’ or m’)
- Must be in high mode first
- LED Display (sleep mode control) Fan Level Control
- Purification Level (High Mode)
- Away Mode
Control Panel
- Power Button
- Fan Speed Control
- Purifier Level Control
- Away Mode Toggle
- Normal/High Toggle
Control Panel Screen
- Fan Speed Indicator
- Mode specific display
- Mode Indicator
- Purification level warning
- Maintenance Reminders
- Away Mode Warning
Mode specific display
Mode Specific Display
- Normal – Technology Indicator (PCO/NCC*)
- High- Square Footage Indicator
- Away – Mode Duration Indicator (hours:minutes)
Routine Maintenance
To run efficiently, your CASPR COMPACT CA requires cleaning on a 60 to 90 day cycle. The best way to tell if the Filter Assembly needs to be cleaned is to check the front grill for dust. If the front grill is dusty, you should remove and clean the Filter Assembly. The NCC cell should also be replaced once every 2-years.
- Removing the Rear Cover
1. Turn off the unit with the Power button.
2. Unplug the unit from the power source and then remove the power cord from the back of the unit.
3. Unscrew and remove the Rear Cover screw located above the Power Cord Port.
4. With two hands, slide the back cover up and lift it away from the machine.
5. Wipe the rear cover with a damp cloth and set to the side.
- Removing and Cleaning the Filter Assembly
1. Unit should be powered OFF and Power Cord should be disconnected when Cleaning/Disassembling/
2. Reassembling/Servicing.
3. Remove the rear cover.
4. Grasp the top of the Filter, lift slightly and pull it away from the unit.
5. Thoroughly rinse the filter with warm water. Shake excess water from the filter and let it dry for an hour before reattaching it.
- Replacing the NCC Cell
1. Unit should be powered OFF and Power Cord should be disconnected when Cleaning/Disassembling/
Reassembling/Servicing.
2. Remove the Rear cover.
3. Remove the filter assembly.
4. Unscrew the cell nuts and disconnect the cell connector.
5. Pull the NCC cell away from the unit and attach the new NCC cell into the nut and connector assembly.
- Reattaching the Filter
1. Gently lay the filter back onto the machine with the diamond pattern facing the interior of the unit and the honeycomb pattern facing out.
2. Replace the rear cover to secure the filter in place.
- Reattaching the Rear Cover
1. Slide the rear cover back into place. You will hear a click.
2. Insert the Rear Cover Screw into the hole above the Power Cord Port and tighten.
- Removing and Cleaning the Front Grille
1. Locate the Front Grille Screw on the front of the machine above the CASPR logo.
2. Using your screwdriver, carefully remove the Front Grille Screw and place where you will easily find it later.
3. Remove the Front Grille by pushing up from the bottom of the Front Grille with your fingers. Be careful to ensure the Ionization Needle (in the top center of the front of the unit) is not damaged.
4. Clean the Front Grille using (compressed air, vacuum cleaner, damp cloth or warm soapy water) and set the Front Grille aside.
5. If the Ionization Needle is visibly dusty, gently clean it with a cotton swab and clear alcohol-based cleaner or rubbing alcohol
- Reattaching the Front Grille
1. Align the Front Grille to the front of the unit, being careful not to damage the Ionization Needle at the top center of the unit.
2. Insert the screw and tighten it.
Troubleshooting
- The Unit Fails to Turn on
1. Verify that the Power Plug is plugged into an operational wall outlet.
2. Ensure that the Power Cord is fully inserted (leaving less than an 1/8”) to the Power Adapter.
3. Ensure that the Power Adapter Plug is fully seated in the receptacle on the back of the unit.
4. Verify the Power Button has been activated on the Control Panel.
5. If the Power Button on the Control Panel fails, use the Power Button on the Remote Control. If the Control Panel fails, contact your distributor or CASPR Group ([www.casprgroup.com](http://www.casprgroup.com)).
- The Unit is Operating in High Mode or Away Mode, but No Noticeable Purification is Being Produced
1. Ensure that the Purification Plate is clean (See Next Page.)
2. The Purification Plate may not be working because it needs to be replaced. Try installing a new Purification Plate.
3. Check the electrical contact arms which touch the plate to ensure that they are making proper contact with the metal weave on the Purification Plate.
4. Ensure the electrical contact arms which touch the plate are clean. Clean them with a soft cloth and rubbing alcohol.
Note: Some CASPR Compact Versions (CASPR COMPACT-CA) do not include purification plates. These versions will remain in Normal PCO/NCC Mode regardless of what mode is displayed on screen.
- Removing and Cleaning the Purification Plate
1. Follow the instructions for removing the Rear Cover and Filter Assembly on Page 12.
2. Grasp the Purification Plate on the ceramic surface and gently pull it out of the grooves on the sides.
3. Using a 50/50 mix of warm water and clear ammonia, or in place of the water and ammonia mixture use 100% white vinegar, soak the Purification Plate for 8 to 10 hours. Do not exceed 10 hours. Using a soft bristled tooth brush, scrub the wire mesh to remove debris lodged inside the mesh. Rinse thoroughly. Allow the Purification Plate to dry completely before reinstalling.
4. Use a soft cloth and rubbing alcohol to clean the metal contacts that touch the Purification Plate.
5. Holding the Purification Plate by the ceramic, align it with the grooves on either side and slowly insert it into the Purification Plate Slot.
Note: Some CASPR Compact Versions (CASPR COMPACT-CA) do not include purification plates.
-
The Purification Plate Generates an Electrical Arc, an Arcing Noise or a Burning Odor
This means the Purification Plate is damaged and must be replaced. The unit may or may not display the Replace Plate LCD reminder. To order a replacement, contact your distributor or CASPR Group (www.casprgroup.com). -
The Cell Does Not Light Up
1. Ensure the Cell Power Connector is properly seated in the Cell Power Connector Outlet.
* Follow the instructions for removing the Rear Cover and Filter Assembly on Page 12.
* Check to see if the Cell Power Connector is properly inserted in the Cell Power Connector Outlet. To ensure the proper connection, gently push until the tabs at the top and bottom of the Cell Power Connector snap into place, securing it to the Cell Power Connector Outlet.
2. If the Cell still fails to operate, it needs to be replaced. Contact your distributor or CASPR ([www.casprgroup.com](http://www.casprgroup.com)).
Limited Warranty
- Your CASPR COMPACT is warranted to be free from all defects in material and workmanship in normal household use for a period of one (l) year from date of purchase. The warranty is granted only to the original purchaser and is subject to the following provisions. This warranty does not cover parts of the CASPR COMPACT that require replacement under normal use. This includes the purifier plate and rear filter assembly. Although the Cell requires periodic replacement, the cell is warranted for the same 1 year period as the purifier. Any damages or malfunctions caused by negligence, abuse, or use not in accordance with the Owner’s Manual are not covered by this warranty. Likewise, any defects or damages caused by unauthorized service or the use of other than Genuine CASPR parts are not covered. CASPR Group will, at its option, repair or replace a defective CASPR COMPACT or part(s) for the CASPR COMPACT that is covered by this warranty As a matter of warranty policy, CASPR Group will not refund the customer’s purchase price.
- To obtain warranty service you must return the defective CASPR COMPACT unit or parts along with proof of purchase to your CASPR distributor. All transportation charges on parts, or units, submitted under this Warranty shall be borne by purchaser. Unless this Warranty is expressly renewed or extended by CASPR Group, any repaired or replaced part of unit shall be warranted to the original purchaser only for the length of the unexpired portion of the original warranty.
- For additional service information, please visit us online at:
www.casprgroup.com
Further Limitations And Exclusions Are as Follows
- Any warranty that may be implied in connection with your purchase or use of the CASPR COMPACT* including any warranty of merchantability or any warranty for Fitness For A Particular Purpose is limited to the duration of this warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
- Your relief for breach of this warranty is limited to the relief expressly provided above. In no event shall CASPR Group be liable for any consequential or incidental damages you may incur in connection with your purchase or use of the CASPR COMPACT. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
- This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
*This warranty remains active for units sold without purification plates, if removed by manufacturer.
Specifications
- Unit
- Size: 13” high x 8.75” wide x 10.75” deep
- Weight: 10.2 lb.
- Coverage: 1500 ft2
- Power Cord
- Fuyuang Switching Power Supply
- Model Number: FY3803000
- Input: 100-240VAC 50/60Hz 2.5A Output: 38VDC 3A
- See the power supply label for certifications and warnings.
- Cell
- Normal Mode Output
- Purification Plate
- High Mode Output: 25-360mg ozone per hour
- Ionization Needle
- 24 to 30 KV, 20-30 Khz Ion Generation Pulsator
- 6 KV DC Needle Ion Generator