LIGHTRONICS FXLD2512B5I6 LED Wash Bar Fixture Owner’s Manual

June 12, 2024
LIGHTRONICS

LIGHTRONICS FXLD2512B5I6 LED Wash Bar Fixture

Product Information

Feature/Specification Value
LEDS 12, 25W each (RGBWA, 5 in 1)
Beam angle 60
Control system DMX-512 + Stand Alone Modes
DMX channels 5/9
DMX connectors 3 pin XLR I/O
Refresh Rate >3000 Hz
Voltage 100 – 240 VAC 50/60Hz
Max power consumption 330 Watts
Ingress Protection IP20 – Indoor Use Only
Cooling Intelligent Fans (2)
Body material Sheet steel
Body color Black
Size 42.7L x 5D x 5.4H (with brackets)
Weight 19.8 pounds

Product Usage Instructions

DMX Connections
A system using DMX control must be connected as a chain of devices. The control signal cable should proceed from the controller to the first receiving device and then to others in one continuous chain. The fixture has a DMX IN and a DMX OUT connector to be used to connect the chain. The control cable should NOT be split into a multiple run star arrangement with a cable running from the controller directly to each receiving device pack.

Installation
Location: Locate the unit indoors in a well-ventilated area away from moisture and heat. Keep the vent holes clear. Holes are provided on the brackets to install a lighting bar pipe clamp. Use a safety cable when hanging the fixture.

Power Connections
CAUTION: RISK OF ELECTRIC SHOCK
The FXLD2512B5I6 has a blue turn and lock connector for power input. A compatible power cable is provided for connection to a 120 VAC, 15 Amp, 60Hz, grounded service. Push the blue connector on the cable straight into the blue connector on the unit and twist approx. 1/8 turn clockwise to latch it. The white turn and lock connector on the unit is used to pass power on to another FXLD2512B5I6 unit. A mating white connector is also provided.

DMX Connector Pin Assignments
This unit uses 3 pin XLR type connectors. The FXLD2512B5I6 receives DMX on the 3 pin MALE connector on one side of the unit. On the other side of the unit, the 3 pin FEMALE connector is used to connect to the next DMX device on the control chain.

PIN # SIGNAL NAME
1 DMX COMMON
2 DMX DATA
3 DMX DATA +

DMX Termination
A DMX chain should be terminated at the last receiving device on the chain. This is done by installing a commonly available 1/4 Watt, 120 Ohm resistor across the DATA – and DATA + wires at the last device. If you have only a few fixtures very close together and a very short run to the controller, then you may be able to operate without the terminator.

Operation
A control panel on the back of the unit is used to set the operating options. It consists of an LED display and four buttons (MENU, UP, DOWN, and ENTER). Push MENU to access the operating options. Push UP or DOWN to cycle through options. When you reach the option you want to set or change, use the ENTER button to select the option to change. Then use the UP and DOWN buttons to modify the values. Push ENTER to save your changes and activate the option. See the MENU NAVIGATION diagram for additional details.

FEATURES AND SPECIFICATIONS

  • LEDS: 12, 25W each (RGBWA, 5 in 1)
  • Beam angle: 60ᵒ
  • Control system: DMX-512 + Stand Alone Modes DMX channels: 5/9
  • DMX connectors: 3 pin XLR I/O
  • Refresh Rate: >3000 Hz
  • Voltage: 100 – 240 VAC 50/60Hz
  • Max power consumption: 330 Watts
  • Ingress Protection: IP20 – Indoor Use Only
  • Cooling: Intelligent Fans (2)
  • Body material: Sheet steel
  • Body color: Black
  • Size: 42.7″L x 5″D x 5.4″H (with brackets)
  • Weight: 19.8 pounds

DESCRIPTION

The FXLD2512B5I6 is an RGBWA LED lighting fixture. It is suitable for stage, houses of worship, entertainment venues, and other artistic applications. It has several stand-alone control modes and can operate via a DMX-512 external signal.

INSTALLATION

LOCATION
Locate the unit indoors in a well ventilated area away from moisture and heat. Keep the vent holes clear. Holes are provided on the brackets to install a lighting bar pipe clamp. Use a safety cable when hanging the fixture.

POWER CONNECTIONS

The FXLD2512B5I6 has a blue turn and lock connector for power input. A compatible power cable is provided for connection to a 120 VAC, 15 Amp, 60Hz, grounded service. Push the blue connector on the cable straight into the blue connector on the unit and twist approx. 1/8 turn clockwise to latch it. The white turn and lock connector on the unit is used to pass power on to another FXLD2512B5I6 unit. A mating white connector is also provided.
THE LINE CORD IS RATED FOR 7 AMPS MAXIMUM
THE SAFETY GROUND TERMINAL ON THE POWER CABLE MUST BE USED.

DMX CONNECTIONS
A system using DMX control must be connected as a chain of devices. In other words, the control signal cable should proceed from the controller to the first receiving device and then to others in one continuous chain.
The fixture has a DMX IN and a DMX OUT connector to be used to connect the chain. The control cable should NOT be split into a multiple run star arrangement with a cable running from the controller directly to each receiving device pack.

DMX CONNECTOR PIN ASSIGNMENTS
This unit uses 3 pin XLR type connectors. The FXLD2512B5I6 receives DMX on the 3 pin MALE connector on one side of the unit. On the other side of unit, the 3 pin FEMALE connector is used to connect to the next DMX device on the control chain.

PIN # SIGNAL NAME
1 DMX COMMON
2 DMX DATA –
3 DMX DATA +

DMX TERMINATION
A DMX chain should be terminated at the last receiving device on the chain. This is done by installing a commonly available 1/4 Watt, 120 Ohm resistor across the DATA – and DATA + wires at the last device. If you have only a few fixtures very close together and a very short run to the controller, then you may be able to operate without the terminator.

OPERATION

  • A control panel on the back of the unit is used to set the operating options. It consists of an LED display and four buttons (MENU, UP, DOWN, and ENTER).

  • Push MENU to access the operating options. Push UP or DOWN to cycle through options. When you reach the option you want to set or change use the ENTER button to select the option to change. Then use the UP and DOWN buttons to modify the values. Push ENTER to save your changes and activate the option. See the “MENU NAVIGATION” diagram for additional details.

  • There are 8 operation modes: DMX 5 channel, DMX 9 channel, Color Fade, Color Change, Color Select, Manual Level (5 selections), Demo, and Sound.

  • Pushing MENU alternates to display 0XXC for current LED plate temperature. The fan turns on at low speed when temperature is at or above 45° C and will turn back off at or below 34° C. The fan shifts to high speed if temperature increases to 55° C and back to low speed once temperature reaches 49° C.

DMX OPERATION

  • For DMX operation the FXLD2512B5I6 fixture can be configured as a 5 channel or 9 channel unit.
  • Use the dXXX (5 ch) or AXXX (9 ch) menu to set the starting address of the unit. You can select the starting address of the unit with the UP and DOWN buttons.
  • The unit has an LED on the menu display (decimal point). If the LED is flashing, the unit is not receiving signal either from a DMX controller or from a master fixture. LED will disappear once DMX is present.
  • Detailed information on DMX channel operation is given in the tables DMX VALUES AND FUNCTIONS.

MANUAL OPERATION

  • If there is no DMX signal provided to the unit, then setting any of these will result in the unit that was set acting as a master. DMX signals will override all manual settings.

Color Fade (CFXX)

  • The Color Fade mode cycles smoothly through a sequence of colors. Use the CFXX menu to set the speed and activate the option. The range is from 00 to 99 with 99 as the fastest.

Color Change (CCXX)

  • The color change mode cycles through a variety of colors at a user defined speed. Use the CCXX menu to set the rate of speed at which the colors change. The  range is from 00 to 99 with 99 as the fastest.

Color Select (CSXX)

  • For additional manual operations you can use the Color Select menu CSXX to select one of 16 colors and levels. Options from 00-99.

R, G, B, W, A Manual Level Control
You can operate the individual color levels manually using the r000, G000, b000, E000, and Y000 menus. Use the UP and DOWN buttons to change the level, push ENTER when done. The range is 000 – 255 with 255 as the maximum.

Demo Mode (dENo)
The unit cycles through a fixed series of colors and fades. There are no adjustments or settings in this mode. Return to Channel mode to exit Demo.

Sound Mode (Soun)

  • The unit reacts to sounds by changing colors randomly. There are no other settings within this mode.
  • Sound mode can also be activated in 9 channel mode with DMX channel 9 set to 240-255. Intensity can be controlled with DMX channel 1 (0-255).

Dimmer Delay (dEL0)

  • The operation of this function has been discontinued.

MAINTENANCE AND REPAIR

CAUTION DO NOT OPEN UNIT

TROUBLESHOOTING

  • Check that you have power applied to the unit.
  • Check the DMX control cable.
  • Check the address settings of the unit and the controller.

CLEANING

  • Do not use harsh chemicals or solvents when cleaning the fixture. A mild detergent can be used sparingly if needed. Use a cloth, do not spray or apply direct to fixture. Ensure the unit is completely dry before re-use.

REPAIR

  • The fixture contains a 2 Amp 250VAC, fast acting, 5mm x 20mm externally accessible fuse. Replace the fuse ONLY with the same size and type.
  • The FXLD2512B5I6 does not contain any other user serviceable parts. Internal service on the unit by other than Lightronics authorized agents will void the warranty.
  • If service is required, contact the dealer from whom you purchased the item, or contact the Lightronics Service Department, 509 Central Drive, Virginia Beach, VA 23454. Tel: 757 486 3588.

WARRANTY INFORMATION AND REGISTRATION – CLICK LINK BELOW

www.lightronics.com/warranty.html

DMX VALUES AND FUNCTIONS

5 CHANNEL MODE (MODE dXXX)

CHANNEL VALUE FUNCTION
1 0-255 Red Level
2 0-255 Green Level
3 0-255 Blue Level
4 0-255 White Level
5 0-255 Amber Level

9 CHANNEL MODE (MODE AXXX)
*Channel 9 additional characteristics.

  • If DMX is raised to 64-127, then back down, 10-63 colors become Red & Green.
  • If DMX is raised to 128-191, then back down, 64-127 colors become Blue & Green.
  • If DMX is raised to 192-239, then back down, 128-191 colors become Cool White/Warm White.
  • If DMX is raised to 240-254, then back down, 192-239 colors become Cool White/Warm White
CHANNEL FUNCTION VALUE DESCRIPTION
1 Master Dimmer 0-255 Master Dimmer
2 Strobe Control 0-255 Strobe slow to fast
3 Red 0-255 Red Intensity
4 Green 0-255 Green Intensity
5 Blue 0-255 Blue Intensity
6 White 0-255 White Intensity
7 Amber 0-255 Amber Intensity





8

| ****





Color Macro

| 0-9| Applicable to CH2-CH7
10-34| Red Fade In
35-64| Red Full, Green Fade In
65-96| Green Full, Red Fade Out
97-127| Green Full, Blue Fade In
128-159| Blue Full, Green Fade Out
160-190| Blue Full, Red Fade In
191-225| Red, Blue Full, Green Fade In
226-255| RGBW Full, Amber Fade In







9*

| ****

Color Effect Raising DMX Value

| 0-9| CH2-CH7 functions
10-63| Red & Blue (slow to fast)
64-127| Red & Blue (slow to fast)
128-191| Red & Green (slow to fast)
192-239| Blue & Green (slow to fast)


Color Effect Lowering DMX Value

| 239-192| Blue & Green (fast to slow)
191-128| Cool/Warm White (fast to slow)
127-064| Blue & Green (fast to slow)
63-10| Red & Green (fast to slow)
9-0| CH2-CH7 functions
Sound Control| 240-255| Sound Control Activate

www.lightronics.com
Lightronics Inc.
509 Central Drive, Virginia Beach, VA 23454

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

LIGHTRONICS User Manuals