Lightronics FXLD618FR2I Flat Round PAR 18 x 6 Watt LED Lighting Fixture Owner’s Manual

June 12, 2024
LIGHTRONICS

FXLD157FR6I LED FIXTURE
Version 1.1
OWNER’S MANUALLightronics FXLD618FR2I Flat Round PAR 18 x 6 Watt LED
Lighting Fixture

FEATURES AND SPECIFICATIONS

LEDS: 7, 15W each (RGBWA+UV, 6in1)
White LED Color Temperature: 6500K
Beam angle: 25 º (15° Optional)
Control system: DMX-512 + Stand Alone Modes
DMX channels: 6/10
DMX connector: 3 pin XLR I/O
Refresh Rate: >3000 Hz
Voltage: 120 – 240 VAC 50/60Hz
Max power consumption: 105 Watts + Auto Switching
Power Supply
Ingress Protection: IP20 – Indoor Use Only
Cooling: Intelligent Fan
Body material: Die Cast Aluminum
Body color: Black
Size: 9.25″L x 4.65″W x 11.42″H (With Yoke)
Weight: 8.82 lbs. (4.0 kg)

DESCRIPTION

The FXLD157FR6I is a RGBWA+UV LED lighting fixture. It is suitable for stage, houses of worship, entertainment venues, and other artistic applications.
It has several stand-alone control modes and can operate via a DMX-512 external signal. A double yoke enables the fixture to be operated in several positions.

INSTALLATION

LOCATION
Locate the unit indoors in a well ventilated area away from moisture and heat. Keep the vent holes clear. Holes are provided on the yokes to install a lighting bar pipe clamp. Use a safety cable when hanging the fixture.

POWER CONNECTIONS

CAUTION
RISK OF ELECTRIC SHOCK
The FXLD157FR6I has a blue turn and lock connector for power input. A compatible power cable is provided for connection to a 120 VAC, 15 Amp, 60Hz, grounded service. Push the blue connector on the cable straight into the blue connector on the unit and twist approx. 1/8 turn clockwise to latch it. The white turn and lock connector on the unit is used to pass power on to another FXLD157FR6I unit. A mating white connector is also provided. THE LINE CORD IS RATED FOR 7 AMPS MAXIMUM. THE SAFETY GROUND TERMINAL ON THE POWER CABLE MUST BE USED.
DMX CONNECTIONS
A system using DMX control should be connected as a chain of devices. In other words, the control signal cable should proceed from the controller to the first receiving device and then to others in one continuous chain.
The fixture has a DMX IN and a DMX OUT connector to be used to connect the chain. The control cable should NOT be split into a multiple run star arrangement with a cable running from the controller directly to each receiving device.
DMX CONNECTOR PIN ASSIGNMENTS
The FXLD157FR6I uses 3 pin XLR connectors. DMX is received on the MALE connector on the back of the unit. The FEMALE connector is used to connect to the next DMX device on the control chain. The table below shows the pin assignments for the 3 pin DMX cable.

PIN # SIGNAL NAME
1 DMX COMMON
2 DMX DATA –
3 DMX DATA +

DMX TERMINATION
A DMX chain should be terminated at the last receiving device on the chain. This is done by installing a commonly available 1/4 Watt, 120 Ohm resistor across the DATA – and DATA + wires at the last device. If you have only a few fixtures very close together and a very short run to the controller, then you may be able to operate without the terminator.

OPERATION

A control panel on the back of the unit is used to set the operating options. It consists of an LED display and four buttons (MENU, UP, DOWN, and ENTER).

Push MENU to access the operating options. When you reach the option you want to set or change, press ENTER and use UP or DOWN to set a value. Push ENTER again to save your changes and activate the option. See the “MENU NAVIGATION” diagram for
additional details.
The fan on the unit will turn on when temperature is at or above 45° C and will turn back off at or below 34° C.
There are 8 operation modes: DMX 6 channel, DMX 10 channel, Color Fade, Color Change, Color Select, Manual Level (6 selections), Demo and Sound.
DMX OPERATION
For DMX operation, the FXLD157FR6I fixture can be configured as a 6 channel, or 10 channel unit. Use the dXXX (6 ch) or AXXX (10 ch) menu to set the starting address of the unit. You can select the starting address of the unit with the UP and DOWN buttons. Detailed information on DMX channel operation is given in the tables DMX VALUES AND FUNCTIONS.
The unit has an LED on the menu display (decimal point). If the LED is flashing, the unit is NOT receiving signal either from a DMX controller or from a master fixture. The LED will disappear once a valid signal is present.

MANUAL OPERATION

Color Fade (CFXX)
The Color Fade mode cycles smoothly through a sequence of colors. Use the CFXX menu to set the speed and activate the option. The range is from 00 to 99 with 99 as the fastest.
Color Change (CCXX)
The Color Change mode switches continuously through a sequence of colors. Use the CCXX menu to set the sequence speed. The range is from 00 to 99 with 99 as the fastest.
Color Select (CSXX)
The Color Select mode provides a multitude of preprogrammed color macros at various intensities. Use the CSXX to select the desired color and intensity. The range is from 00 to 99.
R, G, B, W, A + UV Manual Level Control You can operate the individual color levels manually using the r000, G000, b000, E000, u000 and Y000 menus. Use the UP and DOWN buttons to change the level, push ENTER when done. The range is 000 – 255 with 255 as the maximum. Demo Mode (dENo) The unit cycles through a fixed series of color and fades. There are no other adjustments or settings in this mode.
Sound Mode (Soun)
The unit reacts to sounds by changing colors randomly. There are no other settings within this mode. Sound mode can also be activated in 10 channel mode with DMX channel 10 set to 240-255. Brightness can be controlled with DMX channel 1 (0-255). Dimmer Delay (dEL0) The operation of this function has been discontinued.

MAINTENANCE AND REPAIR

CAUTION DO NOT OPEN UNIT
RISK OF ELECTRIC SHOCK
RISK OF FIRE

TROUBLESHOOTING

Check that you have power applied to the unit. Check the DMX control cable. Check the address settings of the unit and the controller. If no DMX signal is present, there will be a flashing decimal point between 1 st & 2 nd character on display.
CLEANING
Do not use harsh chemicals or solvents when cleaning the fixture. A mild detergent can be used sparingly if needed. Use a cloth, do not spray or apply direct to fixture. Ensure that the unit is completely dry before reuse.
REPAIR
The fixture contains a 2 Amp 250VAC, fast acting, 5mm x 20mm externally accessible fuse. Replace the fuse ONLY with the same size and type. The FXLD618FR2I does not contain any other user serviceable parts. Internal service on the unit by other than Lightronics authorized agents will void the warranty. If service is required, contact the dealer from whom you purchased the item, or contact the Lightronics Service Department, 509 Central Drive, Virginia Beach, VA 23454. Tel: 757 486 3588.

WARRANTY INFORMATION AND REGISTRATION – CLICK LINK BELOW

www.lightronics.com/warranty.html

DMX VALUES AND FUNCTIONS

  1. CHANNEL MODE
    CHANNEL| VALUE|

FUNCTION

---|---|---
1| 0-255| Warm & Cool White Intensity
2. CHANNEL MODE
CHANNEL| VALUE|

FUNCTION

---|---|---
1| 0 – 255| Warm White Intensity
2| 0 – 255| Cool White Intensity
3. CHANNEL MODE
CHANNEL| VALUE|

FUNCTION

---|---|---
1| 0-255| Dimmer
2| 0-255| Warm White Intensity
3| 0-255| Cool White Intensity
4. CHANNEL MODE
CHANNEL| FUNCTION| VALUE|

DESCRIPTION

---|---|---|---
1| Master Dimmer| 0-255| 0%-100%

Intensity



2

| ****

Strobe Control

| 0-3| No Strobe
4-127| Slow to Fast
128-131| No Strobe
132-255| Random
3| Warm White| 0-255| 0%-100%

Intensity

4| Cool White| 0-255| 0%-100%

Intensity

  1. CHANNEL MODE
    CHANNEL| FUNCTION| VALUE|

DESCRIPTION

---|---|---|---
1| Master Dimmer| 0-255| 0%-100%
Intensity
2| Strobe Control| 0-3| No Strobe
4-127| Slow to fast
128-131| No Strobe
132-255| Random Strobe
3| Warm White| 0-255| 0%-100%
Intensity
4| Cool White| 0-255| 0%-100%
Intensity
5| Static Preset| 0-63| Off
64-127| Warm White
128-191| Cool White
192-255| Neutral White

Lightronics FXLD618FR2I Flat Round PAR 18 x 6 Watt LED Lighting Fixture
-MENU NAVIGATION

www.lightronics.com
Lightronics Inc.
509 Central Drive, Virginia Beach, VA 23454
757 486 3588

Documents / Resources

| Lightronics FXLD618FR2I Flat Round PAR 18 x 6 Watt LED Lighting Fixture [pdf] Owner's Manual
FXLD618FR2I Flat Round PAR 18 x 6 Watt LED Lighting Fixture, FXLD618FR2I, Flat Round PAR 18 x 6 Watt LED Lighting Fixture, Round PAR 18 x 6 Watt LED Lighting Fixture, Watt LED Lighting Fixture, LED Lighting Fixture, Lighting Fixture, Fixture
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LIGHTRONICS User Manuals

Related Manuals