Knightsbridge POTHB1 Potentia IP65 Adjustable Wattage and CCT High Bay Instructions
- June 12, 2024
- Knightsbridge
Table of Contents
Knightsbridge POTHB1 Potentia IP65 Adjustable Wattage and CCT High Bay
Product Information
Product Name | POTHB1 / POTHB2 |
---|---|
Installation & Maintenance Manual | Available |
Safety | This product must be disconnected from the circuit if subjected |
to any high voltage or insulation resistance testing. Irreparable
damage will occur if this instruction is not followed.
General Information| This product contains a light source of energy efficiency
class
D to Regulation (EU) No. 2019/2015 and (UK) 2021 No. 1095. This
product contains a non-replaceable light source and non-replaceable
control gear. Clean with a soft dry cloth only, do not use
aggressive cleaning products or solvents which may damage the
product. Do not use any source of high-pressure washers to maintain
or clean this luminaire. This product should be dismantled for
disposal when it reaches the end of its life. Please see the
website for dismantling instructions. This product should be
recycled in the correct manner when it reaches the end of its life.
Check local authorities for where facilities exist.
Warranty| Manufacturers Declaration of Conformity For ML Accessories
(Knightsbridge)
Electrical products in accordance with UKCA marking
ML Accessories Ltd. declare that all products have been designed,
manufactured, and tested in accordance with the requirements of the
relevant legislation
Product Usage Instructions
Bracket Mounting
- Identify the location for bracket mounting.
- Drill 2 x 10mm holes, ensuring not to infringe with any gas/water pipes or electrical cables.
- Securely tighten the bracket to the surface.
Wiring
Connect the wires as follows:
Wire Color | Connection |
---|---|
Brown | Phase (Live) |
Green/Yellow | Earth |
Blue | Neutral |
Brown and White | Switched Live |
Purple | 0-10V Control Signal |
Function Settings
To change the settings, use the remote control:
- ON/OFF: Hold the ON/OFF button until the brightness indicator light is on. Press once to turn the sensor on/off. When the sensor is off, all functions except BRIGHTNESS and SEND are disabled. The remote control needs to be turned on to change any settings.
- BRIGHTNESS: Press to adjust the dimming level (70% / 80% / 90% / 100%).
- SEND: Press to save the setting after each change. The indicator light will illuminate to confirm the setting. After each setting change, SEND must be pressed to save the setting.
- HOLD TIME STANDBY DIM: Press to adjust the hold time (10s / 1min / 10min / 30min). Press to adjust the standby dimming level (10% / 20% / 30% / 50%).
- STANDBY TIME: Press to adjust the standby time (+ / 1min / 30min / 60min).
- SENSITIVITY: Press to adjust the sensitivity (20% / 50% / 75% / 100%).
- DAYLIGHT LEVEL: Press to cycle through daylight threshold settings (10lx / 30lx / 50lx / 100lx).
- RESET: Press for factory settings: Brightness 70% / Hold time 10s / Sensitivity 20% / Daylight level disabled / Standby dimming level 10% / Standby time +.
- + : Press to increase brightness (0-100%).
- – : Press to reduce brightness (100%-0).
- TEST: Press to test the sensor. In test mode, hold time is 3s and all functions except SENSITIVITY and SEND are disabled.
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by
the end user for future reference and maintenance.
These instructions should be used to aid installation of the following
products: POTHB1 / POTHB2
SAFETY
- This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
- Please isolate mains prior to installation or maintenance
- Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse, or circuit breaker
- Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
- Do not overload this accessory or subject it to conditions outside its rating
- This product is for indoor use only
- This product is Class I and must be earthed
- This product is IP65 rated
INSTALLATION
Note – Microwave sensors may not be suitable for all installations, for example, enclosed spaces, as they are able to detect movement through non- metallic surfaces like plasterboard and thin doors.
Suspension mounting
- To suspend the fitting, screw the mounting hoop into the top of the luminaire (see Fig. 1) then secure using suitable fixing accessories.
Bracket mounting
- Using the POTHB1BRAC or POTHB2BRAC mounting bracket as a template (sold separately), mark the location of the fixing holes, and drill 2 x 10mm holes ensuring not to infringe with any gas/water pipes or electrical cables
- Using a hammer, tap the expansion bolts provided into the 10mm fixing holes (see Fig. 2)
- align the mounting bracket with the expansion bolts, attach the nuts and washers to the bolts, and tighten securely to the surface
- Align the luminaire with the holes on the sides of the bracket then adjust to the desired angle using the screws and nuts attaching the main body to the bracket (see Fig. 3)
WIRING
- Provide power to the required point of installation
- Connect the luminaire to the mains supply ensuring the correct polarity is observed: Live (brown), Earth (green/yellow), Neutral (blue)
- Select the desired power output and color temperature via the switches on the rear of the luminaire (see Fig. 4)
POTHBDALI DALI control module
- The luminaire can be connected to a 0-10V dimmer or controlled via DALI (POTHBDALI is required, control gear and software not supplied)
- Connect the luminaire to the DALI module ensuring the correct polarity is observed: GND (pink), +12V (black and white), 0-10V (purple) (see Fig. 5)
POTHBDALI DALI control module
- The luminaire can be connected to a 0-10V dimmer or controlled via DALI (POTHBDALI is required, control gear and software not supplied)
- Connect the luminaire to the DALI module ensuring the correct polarity is observed: GND (pink), +12V (black and white), 0-10V (purple) (see Fig. 5)
POTHBMS Microwave sensor
- POTHBRC (sold separately) is required to operate the sensor
- Using a screwdriver remove the blanking piece from the centre of the lens
- Insert the sensor into the hole and screw clockwise ensuring a tight seal is made to maintain the IP rating (see Fig. 6)
POTHBRC Remote control
- Insert 2 x AAA batteries (not included)
- Adjust sensor settings as required (see table below)
WARNING
This product must be disconnected from the circuit if subjected to any high
voltage or insulation resistance testing. Irreparable damage will occur if
this instruction is not followed
GENERAL
This product contains a light source of energy efficiency class D to Regulation (EU) No. 2019/2015 and (UK) 2021 No. 1095. This product contains a non-replaceable light source and non-replaceable control gear.
- Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents that may damage the product.
- Do not use any source of high-pressure washers to maintain or clean this luminaire.
- This product should be dismantled for disposal when it reaches the end of its life. Please see the website for dismantling instructions.
- This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities for where facilities exist.
WARRANTY
This product has a warranty of 5 years from the date of purchase. Failure to install this product in accordance with the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of purchase for a free-of-charge replacement. ML Accessories does not accept responsibility for any installation costs associated with the replacement product. Your statutory rights are not affected.
Manufacturers Declaration of Conformity
For ML Accessories (Knightsbridge)
Electrical products in accordance with UKCA marking
ML Accessories Ltd. declares that all products have been designed,
manufactured, and tested in accordance with the requirements of the relevant
legislation
UKCA marking legislation
- UK SI 2016 No. 1091 Electro Magnetic Compatibility Regulations 2016
- UK SI 2016 No. 1101 The Electrical Equipment (Safety) Regulations 2016
- UK SI 2012 No. 3032 Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
- UK SI 2017 No. 1206 Radio Equipment Regulations 2017
- UK SI 2021 No. 1095 The Ecodesign for Energy-Related Products and Energy Information (Lighting Products) Regulations 2021
Included Legislation
- UK SI 2008 No. 2852 UK REACH
- UK SI 2013 No. 3113 WEEE
Safety Standards
Full individual declarations and specific safety standards applicable to
relevant product series can be found on our website
www.mlaccessories.co.uk hereby declare that
the equipment named above has been designed to comply with the relevant
sections of the above-referenced specifications. The products comply with all
essential requirements of the directiveML Accessories Ltd. Unit E Chiltern
Park, Boscombe Road, Dunstable. Bedfordshire, LU5 4LT This declaration becomes
invalid if technical or operational modifications are introduced without ML
Accessories Ltd.’s written consent
SUPPLIED BY (UK) MANUFACTURER
ML ACCESSORIES LTD, UNIT E CHILTERN PARK, BOSCOMBE ROAD, DUNSTABLE LU5 4LT,
WWW.MLACCESSORIES.CO.UK
(EU) AUTHORISED REPRESENTATIVE SLV LIGHTING GROUP, DAIMLERSTRASSE 21-23, 52531
ÜBACH-PALENBERG, GERMANY
EMAIL: EPREL@GROUP.SLV.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>