Product Usage Instructions:

  1. Before starting the installation, gather the necessary supplies:
    • Wrench
    • Screwdriver
    • Level
    • Duct Tape
    • Teflon Tape (for Gas Models)
  2. Position and Level the Dryer
    • Install the dryer before the washer to allow room for attaching the exhaust duct.
    • Select a location with a solid floor. If installing in a residential garage, elevate the dryer 18 inches [457 mm] above the floor.
    • Ensure that no other fuel-burning appliance is installed in the same closet as the dryer.
    • Do not install or store the dryer in an area exposed to water and/or weather.
    • Adjust the leveling legs from inside the dryer using a 1/4 inch driver. All four legs must rest firmly on the floor to evenly distribute the weight of the dryer.
    • The dryer requires sufficient clearance and an adequate air supply for proper operation, ventilation, installation, and servicing. Refer to Figure 3 for minimum clearances.
    • Do not install the dryer behind a lockable, sliding, or hinged door that restricts the full opening of the dryer door.
  3. Attach Exhaust Duct:
    • Use 4-inch [102 mm] metal ducting for exhaust openings.

Note: For detailed dimensions of electric and gas models, refer to the respective diagrams provided in the user manual. For more information and additional instructions, please refer to the complete user manual available at www.alliancelaundry.com using Part Number D510963R11.

DimensionsSpeed -Queen- DV2000WG-Commercial-Dryers
\(2\)

A 22.38 in. [569 mm]
B 8.0 in. [203 mm]
C * 36 in. [914 mm]
D * 40.25 in. [1022 mm]
E * 43 in. [1092 mm]
F 15.4 in. [391 mm]
G * 15.44 in. [392 mm]
H 26.9 in. [683 mm]
I * 4.0 in. [102 mm]
J 0.4 in. [11 mm]
K * 4.5 in. [114 mm]
L 28 in. [711 mm]
M 23.5 in. [597 mm]
NOTE: Exhaust openings are 4 inch [102 mm] metal ducting. * With

leveling legs turned into base.

Speed -Queen- DV2000WG-Commercial-Dryers \(2\)

A 22.38 in. [569 mm]
B 8.0 in. [203 mm]
C * 36 in. [914 mm]
D * 40.25 in. [1022 mm]
E * 43 in. [1092 mm]
F 15.4 in. [391 mm]
G * 15.44 in. [392 mm]
H * 2.8 in. [70 mm]
I 2.3 in. [60 mm]
J 26.9 in. [683 mm]
K * 4 in. [102 mm]
L 0.4 in. [11 mm]
M * 4.5 in. [114 mm]
N 28 in. [711 mm]
O 23.5 in. [597 mm]
NOTE: Exhaust openings are 4 inch [102 mm] metal ducting. * With

leveling legs turned into base.

Installation

Before You Start Supplies
For most installations, the basic supplies you will need are:

  1. Wrench
  2. Screwdriver
  3. Level
  4. Duct Tape
  5. Teflon Tape (Gas Models)

WARNING
Any disassembly requiring the use of tools must be performed by a suitably qualified service person.

Order of Installation Steps

  1. Position and level the dryer.
  2. Connect dryer to exhaust system.
  3. For gas models only, connect the gas supply pipe. Check for gas leaks.
  4. For electric models only, connect the electrical cord.
  5. Reverse the door, if desired.
  6. Wipe out the inside of the dryer.
  7. Plug in the dryer.
  8. Recheck steps.
  9.  Check heat source.

Position and Level the Dryer

  1. Install dryer before washer. This allows room for attaching exhaust duct.

  2. Select a location with a solid floor. Dryers installed in residential garages must be elevated 18 inches [457 mm] above the floor.
    No other fuel burning appliance should be installed in the same closet with the dryer.
    The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
    Leveling legs can be adjusted from inside the dryer with 1/4 in. driver. All four legs must rest firmly on the floor so the weight of the dryer is evenly distributed.
    The dryer needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances are shown in Figure 3 ).
    The dryer must not be installed behind a lockable door, a sliding door or a door with a hinge on the opposite side to that of the dryer, in such a way that a full opening of the dryer door is restricted.

  3. Place the dryer in position, and adjust the legs until the dryer is level from side to side and front to back. The dryer must not rock.

  4. Dryer Base

  5. Level

  6. Leveling Leg

Front View (Without Closet Door) Side View (Closet Door) Front View (Closet Door)

  1. Closet Door
  2. Centered Air Openings (G) (2 Openings minimum)
  3. Outer Wall of Enclosure

Area

|

Description

| Free Standing/Alcove Installation|

Closet Installation

---|---|---|---
A| Dryer sides and rear clearance| 0 in. [0 mm]| 0 in. [0 mm]
B| Dryer top clearance| 12 in. [305 mm]| 12 in. [305 mm]
C| Dryer front clearance| Not Applicable| 2 in. [51 mm]
D| Exhaust duct clearance to combustible material| 2 in. [51 mm]| 2 in. [51 mm]
E| Weather hood to ground clearance| 12 in. [305 mm]| 12 in. [305 mm]
F| Distance from floor or ceiling to air opening edge| Not Applicable| 3 in. [76 mm]
G| Area of centered air openings in closet door. Louvered door with equivalent air openings is acceptable. (Minimum clearan- ces are shown.)| Not Applicable| 40 sq. in./open [260 sq. cm/ open]
H| For new installations, locate top of wall vent 42 inches [1067 mm] above floor to make venting easier to connect.| 42 in. [1067 mm]| 42 in. [1067 mm]
| Rear clearance is minimum. 2 inches [51 mm] is recommended for utility connection. 6 inches [152 mm] is recommended when venting through rear of unit.

NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting easier to connect.

IMPORTANT: In mobile home installations, gas dryers MUST be permanently attached to the floor at the time of installation. Order No. 526P3 Dryer Installation Kit  (available at extra cost) for a manufactured (mobile) home installation. Follow the instructions supplied with the kit.

Connect Dryer Exhaust System

WARNING
To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.

WARNING
A clothes dryer produces combustible lint. To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors.

WARNING
This gas appliance contains or produces a chemical or chemicals which can cause death or serious ill-ness and which are known to the State of California to cause cancer, birth defects, or other reproductive harm. To reduce the risk from substances in the fuel or from fuel combustion, make sure this appliance is installed, operated, and maintained according to the instructions in this manual.

WARNING
To reduce the risk of fire, DO NOT use plastic or thin foil ducting to exhaust the dryer.

WARNING
Risk of fire. Do not install a booster fan in the exhaust duct.

NOTE: The booster fan warning does not apply to clothes dryers intended to be installed in a multiple clothes dryer system, with an engineered exhaust duct system that is installed per the clothes dryer manufacturer’s guidelines.

  1. Correct
  2. Incorrect
  • DO NOT use plastic, thin foil or type B ducting. Rigid metal duct is recommended.

  • Locate dryer so exhaust duct is as short as possible.

  • Be certain old exhaust ducts are cleaned before installing your new dryer.

  • Use 4 inch [102 mm] diameter rigid or flexible metal duct.

  • The male end of each section of duct must point away from the dryer.

  • Use as few elbows as possible.

  • Use of duct tape or pop-rivets on all seams and joints is recommended, if allowed by local codes. DO NOT use sheet metal screws or fasteners on exhaust pipe joints which extend into the duct and catch lint.

  • For proper operation, it is important that the dryer has an ample amount of outside make-up air. The free area of any opening for the introduction of outdoor air must be at least 25 in.2 [163 cm2] .

  • When exhausting the dryer to the outdoors, the dryer can be installed with “0” inch clearance at sides and rear. Clearance of the duct from combustible construction must be a mini-mum of 2 inches [5.08 cm] .

  • Ductwork that runs through unheated areas must be insulated to help reduce condensation and lint build-up on pipe walls.
    In mobile home installations, dryer exhaust duct must be se-cured to mobile home structure.
    Dryer exhaust duct MUST NOT terminate under mobile home.
    Exhaust duct must not be connected to any other duct, vent, or chimney.
    Never install flexible duct in concealed spaces, such as a wall or ceiling.

  • Dryer exhausts 220 cfm (measured at back of dryer).

  • Energy efficient buildings with low air infiltration rates should be equipped with an air exchanger that can accommodate on demand make-up air needs in the laundry room. These devices can be obtained through your building contractor or building material suppliers.

  • Static pressure in exhaust duct should not be greater than 0.6 inches water column [1.5 cm water column] measured with manometer placed on exhaust duct two feet [610 mm] from dryer (check with dryer running and no load).

  • Exhausting dryer in hard-to-reach locations can be done by installing 521P3 Flexible Metal Vent Kit (available as option-al equipment at extra cost).

  • Failure to exhaust dryer properly will void warranty.

  • The air that is expelled should not be discharged into a conduit that is used to discharge fumes from of appliances that burns gas or other fuels.

NOTE: Venting materials are not supplied with the dryer (obtain locally).

IMPORTANT: DO NOT block the airflow at the bottom of the dryer’s front panel with laundry, rugs, etc. Blockage will decrease airflow through the dryer, thus reducing the efficiency of the dryer.

Exhaust Direction
The dryer can be exhausted to the outdoors through the back, left, right or bottom of the dryer. EXCEPTION: Gas dryers cannot be vented out the left side because of the burner housing.
Dryer is shipped from factory ready for rear exhaust.
Exhausting the dryer through sides or bottom can be accomplished by installing a Directional Exhaust Kit, 528P3, available as optional equipment at extra cost.

Exhaust System
For best drying results, recommended maximum length of exhaust system is shown in Table 2 .
To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally).

NOTE: Weather hood should be installed at least 12 inches [305 mm] above the ground. Larger clearances may be necessary for installations where heavy snow- fall can occur.

Number of 90° Elbows Weather Hood Type
Recommended Use Only for Short Run Installations
****

D673I_SVG
1. 4 in. [102 mm]

| ****

1
D802I_SVG
1. 2.5 in. [64 mm]

Maximum length of 4 in. [102 mm] diameter rigid metal duct.
0| 65 feet [19.8 m]| 55 feet [16.8 m]
1| 55 feet [16.8 m]| 47 feet [14.3 m]
2| 47 feet [14.3 m]| 41 feet [12.5 m]
3| 36 feet [11.0 m]| 30 feet [9.1 m]
4| 28 feet [8.5 m]| 22 feet [6.7 m]

Table 2

NOTE: Deduct 6 feet [1.8 m] for each additional elbow.
NOTE: The maximum length of a 4 in. [102 mm] diameter flexible metal duct must not exceed 7.87 ft. [2.4 m] , as required to meet UL2158, clause 7.3.2.A.

Gas Dryers – Connect Gas Supply Pipe

WARNING
To reduce the risk of gas leaks, fire or explosion:

The dryer must be connected to the type of gas as shown on nameplate located in the door recess.
Use a new flexible stainless steel connector. Use pipe joint compound insoluble in L.P. (Lique-fied Petroleum) Gas, or Teflon tape, on all pipe threads.
Purge air and sediment from gas supply line be-fore connecting it to the dryer. Before tightening the connection, purge remaining air from gas line to dryer until odor of gas is detected. This step is required to prevent gas valve contamination. Do not use an open flame to check for gas leaks. Use a non-corrosive leak detection fluid.
Any disassembly requiring the use of tools must be performed by a suitably qualified service per-son.

  1. Make certain your dryer is equipped for use with the type of gas in your laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8 inch NPT gas connection.
    NOTE: The gas service to a gas dryer must conform with the local codes and ordinances, or in the ab-sence of local codes and ordinances, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CAN/CSA-B149.1 Natural Gas and Propane Installation Code.
    Natural Gas, 1000 Btu/ft3 [37.3 MJ/m3 ] , service must be sup-plied at minimum 5.0 inch [127 mm] water column pressure to maximum 10.5 inch [267 mm] water column pressure.
    For proper operation at altitudes above 3000 feet [915 m] the nat-ural gas valve spud orifice size must be reduced to ensure com-plete combustion. Refer to Table 3 . Natural Gas Altitude Adjustments

    Alti tude| Orifice Size| ****





Part No.

feet [m]| No.| inches [mm]
3000 [915]| 43| 0.0890 [2.26]| D503778
6000 [1830]| 44| 0.0860 [2.18]| 58719
8000 [2440]| 45| 0.0820 [2.08]| D503779
9000 [2740]| 46| 0.0810 [2.06]| D503780
10000
[3050]| 47| 0.0785
[1.99]| D503781

Table 3

  1. Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap.
  2. Connect to gas supply pipe.

NOTE: When connecting to a gas line, an equipment shut-off valve in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the Natural Gas and Propane Installation Code, CSA B149.1 must be installed within 6 feet [1.8 m] of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to Figure 5 .

  1. 1. New Stainless Steel Flexible Connector – (Use design CSA certified connector) Use only if allowed by local co-des

  2. 1/8 in. NPT Pipe Plug

  3. Equipment Shut-Off Valve

  4. Black Iron Pipe:
    Shorter than 20 ft. [6.1 m] – Use 3/8 in. [9.5 mm] pipe. Longer than 20 ft. [6.1 m] – Use 1/2 in. [12.7 mm] pipe.

  5. 3/8 in. NPT Gas Connection

Figure 5
Tighten all connections securely but don’t overtighten to avoid breaking or bending the gas valve bracket. Turn on gas and check all pipe connections (internal & external) for gas leaks with a non-corrosive leak detection fluid.

NOTE: The dryer and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pres-sures in excess of 1/2 psi [3.45 kPa] . Refer to Check Heat Source.
NOTE: DO NOT connect the dryer to L.P. Gas Service without converting the gas valve. Install L.P. Gas Con-version Kit 649P3, available at extra cost.
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft.3 [93.1 MJ/m3 ] , service must be supplied at 10 ± 1.5 inch water column pressure.
For proper operation at altitudes above 3000 feet [915 m] the L.P. gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Table 4 .

  • © Copyright, Alliance Laundry Systems LLC –
  • DO NOT COPY or TRANSMIT

L.P. Altitude Adjustments

Altitude| Orifice Size| Part No.
feet [m]| No.| inches [mm]
3000 [915]| 55| 0.0520
[1.32]| 58755
8000 [2440]| 56| 0.0465
[1.18]| D503786

Table 4

Connect Electrical Plug (Electric Dryer Only)

Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 wire electrical supply. Refer to serial plate for specific electrical re-quirements.

IMPORTANT: Use only a new U.L. listed No. 0 (copper wire only) three conductor power supply cord kit rated 240 Volts (minimum) 30 Amperes and labeled as suita-ble for use in a clothes dryer.

NOTE: The wiring diagram is located in the control hood.

WARNING
To reduce the risk of fire, electric shock, serious in-jury or death, all wiring and grounding MUST con-form with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer.

Grounding Information
This dryer must be properly connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.
The dryer has its own terminal block that must be connected to a separate branch, 60 Hertz, single phase circuit, AC (alternating current) circuit, fused at 30 Amperes (the circuit must be fused on both sides of the line). Electrical service for the dryer should be of maximum rated voltage (208 or 240 Volt, depending on heat-Installation ing element) listed on the nameplate. Do not connect dryer to 110, 115, or 120 Volt circuit.
Heating elements are available for field installation in dryers which are to be connected to electrical service of different volt-age than that listed on serial plate, such as 208 Volt.

NOTE: Branch circuit wire size requirements to laundry room outlet are shown in table below.

Wire Length Wire
Less than 15 ft. [4.5 m] Listed No. 10 AWG Copper wire only
Longer than 15 ft. [4.5 m] Listed No. 8 AWG Copper wire only

Table 5
The power cord connection between wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of power cord and gauge of wire must conform to local codes.

Connecting Power Cord with Three-Wire Plug

NOTE: Four-wire cord is required for new branch-cir-cuit installations, mobile homes or where codes do not permit grounding through neutral.
NOTE: The power cord is NOT supplied with the elec-tric dryer. Type of power cord and gauge of wire must conform to local codes and instructions. The method of wiring the dryer is optional and subject to local code requirements.
NOTE: Connect the dryer to the power supply with the MAXIMUM RATED VOLTAGE listed on the serial plate.
NOTE: Use COPPER WIRE only.

  • Shorter than 15 ft. (4.5 m) – use 10 AWG
  • Longer than 15 ft. (4.5 m) – use 8 AWG
  1. A typical 30-Amp Three-Wire Receptacle NEMA Type 10-30R
  2. 120 ± 12 V.A.C.
  3. 240 ± 12 V.A.C.
  4. Intermediate Fuse Box (may be omitted if service entrance box is fused)
  5. Wall Receptacle
  6. Power Supply
  7. 3-Wire Earth/Ground Neutral 120/240 Volt, 60 Hertz AC 1 Phase Service Entrance Switch Box (Refer to NOTE above)
  8. 30 Ampere Fuses or Circuit Breaker
  9. Neutral Wire
  10. Metallic or Non-Metallic Sheathed Cable (Copper Wire Only)
  11. Power Cord (Not supplied with dryer)
  12. Neutral
  13. Terminal Block in Dryer
  14. Intermediate Shut-Off Box (may or may not be fused)
  15. Direct Connection
  16. Power Cord Connection

Figure 6

  1. Disconnect power to dryer.

  2. Remove access cover from rear of dryer. Figure 7

  3. Use a strain relief and insert end of power cord through power supply hole. Figure 8

  4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 9 .

  5. “L1” Terminal

  6. Neutral Terminal

  7. “L2” Terminal
    Figure 9

  8. Tighten all screws firmly.
    IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.

  9. Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.

  10. Check the continuity of the earth/ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center earth/ground pin of the plug and the green screw on the back of the cabinet.

  11. Reinstall access cover and screw.

Connecting Power Cord with Four-Wire Plug

NOTE: Four-wire cord is required for new branch-cir-cuit installations, mobile homes or where codes do not permit grounding through neutral.

  1. Typical Four-Wire Receptacle
  2. Power Cord – Not Supplied with Dryer
  3. Strain Relief Nut
  4. Strain Relief
  5. 0 V.A.C.
  6. 240 ± 12 V.A.C.
  7. 120 ± 12 V.A.C.

Figure 10

  1. Disconnect power to dryer.

  2. Remove access cover from rear of dryer. Figure 11

  3. Remove the three screws holding the three wires to the terminal block terminals. Save these screws. Loosen the strain relief screw and pull the cord or wires out through the rear of the dryer. Figure 12

  4. Remove earth/ground screw save for use in Step 6. Remove wire and use in Step 7.

  5. Ground Screw
    Figure 13

  6. Use a strain relief and insert end of power cord through power supply hole. Figure 14

  7. Attach power cord earth/ground (green) wire to rear bulkhead using earth/ground screw removed in Step 4.

  8. White

  9. “L2” Terminal

  10.  Black

  11. Green

  12. Red

  13. Neutral Terminal

  14. “L1” Terminal
    Figure 15

  15. Use the three screws from the accessories bag to attach the re-maining power cord wires to the terminal block as follows:

    • a. Red wire to “L1” terminal.
    • b. Black wire to “L2” terminal.
    • c. White wire to Neutral terminal.
      NOTE: When installing the white wire, loop the free eyelet end of the earth/ground to neutral wire (re-moved in Step 4) and attach along with the white wire to the neutral (center) terminal on the terminal block.
  16. Tighten all screws firmly.
    IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.

  17. Check the continuity of the ground connection before plug-ging the cord into an outlet. Use an acceptable indicating de-vice connected to the center grounding pin of the plug and the green screw on the back of the cabinet.

  18. Reinstall access cover and screw.

Reverse Door, if Desired
The door on this dryer is completely reversible. To reverse door proceed as follows:

  1. Remove four hinge attaching screws. Figure 16
  2. Remove all nine screws. Figure 17
  3. Pull bottom of door liner out, then pull down, removing door liner from door panel. Figure 18
  4. Rotate door panel 180 degrees as shown. Figure 19
  5. Remove door strike from door liner and reinstall on opposite Figure 20
  6. Insert liner under flange on bottom of door, then push top of door liner into place. Figure 21
  7. Reinstall nine screws removed in Step 2. Figure 22
  8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. Figure 23
  9. Reinstall four hinge attaching screws, removed in Step 1.

Figure 24

Wipe Out Inside of Dryer
Before using dryer for the first time, use an all-purpose clean-er, or a detergent and water solution, and a damp cloth to re-move shipping dust from inside dryer drum.

Figure 25

 Plug In the Dryer

Electric Dryer
Connect the dryer to an electrical power source. Refer to Electric Dryer Only – Connect Electrical Plug for information on con-necting power cord.

  • © Copyright, Alliance Laundry Systems LLC –
  • DO NOT COPY or TRANSMIT

Figure 26

Gas Dryers
Dryer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong grounding plug. Refer to serial plate for specific electrical requirements.

NOTE: The wiring diagram is located in the control hood.

WARNING
To reduce the risk of fire, electric shock, serious in-jury or death, all wiring and grounding MUST con-form with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer.

When plugging in the dryer:

  • Do not overload circuits.
  • Do not use an adapter.
  • Do not use an extension cord.
  • Do not operate both a washer and gas dryer on the same cir-cuit. Use separately fused 15 amp circuits.

The dryer is designed to be operated on a separate branch, polar-ized, three- wire, effectively grounded, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or circuit breaker.
The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 120 Volts AC (alternating current) 15 Amps. Re-fer to Figure 27 to determine correct polarity of the wall recepta-cle.

Grounding Information
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The dryer Installation
is equipped with a cord having an equipment-grounding conduc-tor and a 3 prong grounding plug. The three-prong grounding plug on the power cord should be plugged directly into a polar-ized three-slot effectively grounded receptacle rated 110/120 Volts AC (alternating current) 15 Amps.

WARNING
This dryer is equipped with a three-prong (ground-ing) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or re-move the grounding prong from this plug.

WARNING
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded.

Do not modify the plug provided with the dryer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that listed on the dryer’s nameplate, the qualified electrician should correct the problem.
Do not operate other appliances on the same circuit when this ap-pliance is operating.

WARNING
To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source.
Plug cord into separately fused 15 Amp circuit.

  1. “L1”
  2. Earth/Ground
  3. Neutral Side
  4. Neutral Side
  5. Round Earth/Ground Prong
  6. 0 V.A.C.
  7. 120±12 V.A.C.
  8. 120±12 V.A.C.

Figure 27

Recheck Steps
Refer to Installer Checklist on the back cover of this manual and make sure that dryer is installed correctly.

Check Heat Source

Electric Dryers

  1. Close the loading door and start the dryer in a heat setting (re-fer to the operation instructions).
  2. After the dryer has operated for three minutes, the exhaust air or exhaust pipe should be warm.

Gas Dryers

IMPORTANT: This operation is to be conducted by qualified personnel only.

  1. To view the burner flame, remove the lower front panel of the dryer.

  2. Close the loading door and start the dryer in a heat setting (re-fer to the operation instructions). The dryer will start, the ig-niter will glow red and the main burner will ignite. IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition.
    IMPORTANT: If igniter does not light, make sure gas is turned on.
    After the dryer has operated for approximately five minutes, observe burner flame through lower front panel.
    Adjust the air shutter to obtain a soft, uniform blue flame. (A lazy, yellow- tipped flame indicates lack of air. A harsh, roar-ing, very blue flame indicates too much air.) Adjust the air shutter as follows:

    • a. Loosen the air shutter lockscrew.
    • b. Turn the air shutter to the left to get a luminous yellow-tipped flame, then turn it back slowly to the right to obtain a steady, soft blue flame.
    • c. After the air shutter is adjusted for proper flame, tighten the air shutter lockscrew securely.
  3. Reinstall the lower front panel.
    WARNING
    To reduce the risk of serious injury or death, low-er front panel must be in place during normal op-eration.

  4. After the dryer has operated for approximately three minutes, exhaust air or exhaust pipe should be warm.

Shut-off Valve Only Applicable on Certain Models

  1. Air Shutter Lockscrew
  2. Air Shutter
  3. 1/8 in. [3.1 mm] Pipe Plug (For checking manifold pressure)
  4. Shut-off Valve Open Position
  5. Shut-off Valve Closed Position
  6. Shut-off Valve Handle

Installer Checklist

Fast Track for Installing the Dryer

1| Position and Level the Dryer.| ****

**** DRY2634N_SVG

| 6| Wipe Out Inside of Dryer.| ****

D618I_SVG1

---|---|---|---|---|---
| CHECK| | CHECK
2| Connect Dryer Exhaust System.| ****

DRY1915N_SVG1

| 7| Plug In the Dryer.| Electric


D275I_SVG1


Gas


D254I_SVG

| CHECK| | CHECK
3| GAS ONLY

•       Connect Gas Sup- ply Pipe.

•       Check for Gas Leaks.

| ****| 8| Recheck Steps.
| CHECK| | CHECK
4| ELECTRIC ONLY

•       Connect Electrical Cord.

| ****

D699I_SVG1

| 9| Check Heat Source| ****

D702I_SVG1

| CHECK| | CHECK
5| Reverse Door, if De- sired.| ****

**** D675I_SVG1

|
| CHECK

Refer to the manual for more detailed information

  • © Copyright, Alliance Laundry Systems LLC
  • DO NOT COPY or TRANSMIT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Speed Queen User Manuals

Related Manuals