AO Smith Multi Flue Commercial Gas Water Heater with Booster Two Temperature Instructions
- June 12, 2024
- AO Smith
Table of Contents
AO Smith Multi Flue Commercial Gas Water Heater with Booster Two
Temperature
Product Information
This product is a multi-flue booster heater with two temperature settings. It is designed to provide hot water for various applications.
The product features several components, including:
- Temperature & Pressure Relief Valve
- Pressure Relief Valve
- Full Port Ball Valve Check Valve
- Circulating Pump
- Temperature Gauge
- Tank Temperature Control
- Water Flow Switch
- Drain
- Hot Outlet at Stored Temperature
- Pre-Heater
- Finished Floor
- Boosted Water Outlet
- Typical Booster Heater
- Booster Return (if used)
- Hot Water Return
- Cold Water Supply
- Expansion Tank
Please note that this diagram shows a suggested pipingconfiguration and other devices. It is important to check withlocal codes and ordinances for any additional requirements specific to your location.
Product Usage Instructions
Before using the booster heater, ensure that all necessary components are properly installed according to the local codes and ordinances.
- Connect the cold water supply to the designated inlet on the booster heater.
- If using a booster return, connect it to the appropriate connection on the booster heater.
- Connect the hot water return line to the designated outlet on the booster heater.
- If applicable, connect the pre-heater to the appropriate connection on the booster heater.
- Ensure that all connections are secure and leak-free.
- Set the tank temperature control to the desired temperature.
- Verify that the temperature and pressure relief valve is properly set within the pressure rating of the system components.
- Check that the circulating pump is functioning correctly.
- Monitor the temperature gauge to ensure that the water is being heated to the desired temperature.
- If necessary, adjust the tank temperature control to achieve the desired hot water temperature.
Please refer to the product manual or contact A. O. Smith Corporation at 800-527-1953 or visit their website at www.hotwater.com for further technical information or assistance.
WARNING : THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS
WIRING DIAGRAM
LEGEND
-
TEMPERATURE & PRESSURE RELIEF VALVE
-
PRESSURE RELIEF VALVE
-
CIRCULATING PUMP
-
TANK TEMPERATURE CONTROL
-
DRAIN
-
FULL PORT BALL VALVE
-
CHECK VALVE
-
TEMPERATURE GAGE
-
WATER FLOW SWITCH
NOTES:
- Preferred piping diagram.
- The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system.
- Service valves are shown for servicing unit. However, local codes shall govern their usage.
November 2009 | Printed in U.S.A. | © A. O. Smith
For Technical Information and Automated Fax Service, call
800-527-1953 or visit
www.hotwater.com. A. O. Smith Corporation reserves
the right to make product changes or improvements without prior notice.
http://waterheatertimer.org/Booster-heater.html