Product Information
The product is a kitchen appliance with the following dimensions:
- Side View: 21 7/8″ (555) *
- Front View: 83 9/16″ (2123) + 1/4(6)
- 74 3/8″ (1890)
- 83 9/16″ (2123) + 1/4(6)
The cutout dimensions for installation are as follows:
- Side View: b
- Front View: a
- Front View: a
- 84″
- 30″
- 2134 mm
- 762 mm
- Minimum depth required
The electrical and water connection requirements are as follows:
A properly-grounded, horizontally-mounted electrical receptacle should be
installed according to the provided drawing. To connect to the water supply
system, use a 1/4″ waterline with a minimum length of 60″ (1500 mm). The
placement of the connections within the opening may require additional cabinet
depth.
Product Usage Instructions
If the appliance is not connected through the side profile trims to secured cabinetry, anti-tip brackets must be installed. Ensure that the appliance is securely connected to prevent tipping. For a flush inset depth of 25″ (635 mm), the maximum door panel thickness should be 15/16″ (24 mm). The maximum door panel weight should not exceed 66 lbs (30 kg). Please refer to the Door Panel Specs, Built-in Food Preservation Design Guide, or Installation Manual for panel dimensions available.
PRODUCT DIMENSIONS
CUTOUT DIMENSIONS
For a 25″ (635) flush inset depth, max door panel thickness is 15/16″ (24).
Max door panel weight is 66 lbs (30 kg).
- (a) Anti-tipping brackets – included with appliance
- (b) Panel dimensions available on Door Panel Specs, Built-in Food Preservation Design Guide or Installation Manual
ELECTRICAL & WATER CONNECTION
- A properly-grounded, horizontally-mounted electrical receptacle should be installed according to this drawing.
- To connect to the water supply system, use a 1/4” waterline with a minimum lenght of 60″ (1500).
- Connection(s) placement within the opening may require additional cabinet depth.
INSTALLATION REQUIREMENTS
If the appliance(s) is not connected through the side profile trims to secured cabinetry anti-tip brackets must be installed.
Dimensions in parentheses are millimeters unless otherwise specified.