POLAR CF760 G-Series Triple Tank Chilled Drinks Dispenser Instruction Manual
- June 12, 2024
- Polar
Table of Contents
Chilled Drinks
Dispenser
**Instruction manual
Chilled Drinks Dispenser
Handleiding
Model
CF760 / CF761 / GG753
**
Safety Instructions
-
Position on a flat, stable surface.
-
Install the appliance where it can be overseen by trained personnel.
-
Always carry, store and handle the appliance in a vertical position.
-
A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
-
Consult Local and National Standards to comply with the following:
– Health and Safety at Work Legislation
– BS EN Codes of Practice
– Fire Precautions
– IEE Wiring Regulations
– Building Regulations -
DO NOT immerse in water, or use jet/pressure washers to clean the appliance.
-
Not suitable for outdoor use.
-
Always switch off and disconnect the power supply to the appliance before cleaning.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
-
Por lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
-
Keep all packaging away from children. Dispose of the packaging in accordance to the regulations of local authorities.
-
Polar recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection,
Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing. -
If the power cord is damaged, it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard.
-
POLAR recommend that this product is connected to a circuit protected by an appropriate RCD (Residual Current Device).
Caution: Risk of Fire
-
Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
Warning: Keep all ventilation openings clear of obstruction. Unit should not be boxed in without adequate ventilation. -
Warning: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
-
Warning: Do not damage the refrigerant circuit.
-
Warning: Do not use electrical appliances inside the food storage compartments of the appliance.
Product Description
CF760 – Single Chilled Drinks Dispenser
CF761 – Double Chilled Drinks Dispenser
GG753 – Triple Tank Chilled Drinks Dispenser
Introduction
Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.
Pack Contents
The following is included:
- Polar Chilled Drinks Dispenser
- Tank, tank Gasket & Lid (CF760 x 1, CF761 x 2, GG753 x 3)
- Tap Assembly (CF760 x 1, CF761 x 2, GG753 x 3)
- Spare Tank Gasket and O-ring (CF760 x 1, CF761 x 2, GG753 x 3)
- Instruction Manual
- Mixing Paddle (CF760 x 1, CF761 x 2, GG753 x 3)
- Drip Tray (CF760 x 1, CF761 x 2, GG753 x 3)
POLAR prides itself on quality and service, ensuring that at the time of unpacking the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR dealer immediately.
Installation
Note: Not for use in vans or trailers, food trucks or similar vehicles.
If the unit has not been stored or moved in an upright position, let it stand
upright for approximately 12 hours before operation.
If in doubt allow to stand.
- Remove the appliance from the packaging and remove the protective film from all surfaces.
- When positioning the dispenser, maintain a distance of 20cm (7 inches) between the appliance and walls or other objects for ventilation. Increase this distance if the obstacle is a heat source.
- If necessary, adjust the screw legs of the dispenser to stabilise it.
Assembly/Disassembly
-
Insert the large rubber gasket into the bottom of the tank [Fig. 1].
-
Holding the top and bottom of the tap lever, gently bend the lever in the middle [Fig. 2].
-
Push the two hooks at the back of the tap lever into the slot in the front of the tank and drop into place [Fig. 3].
-
Lower the tank on to the cooling column. Locate the four feet on the bottom of the tank to the mounts on top of the cooling unit.
Note: Lubricate the gasket with a small amount of water if the gasket is too tight. -
Roll the O-ring down the tap shaft [Fig. 4] and insert thin end first into the hole in the tank.
-
Ensure the bottom of the tap slots into the gap in the tap lever.
-
Hang the drip tray from the slots on the front of dispenser [Fig. 5].
-
Securely fix the lid to the tank.
Operation
Filling
- Switch Off the dispenser.
- Remove the lid and pour the liquid into the tank.
- Replace the lid.
WARNING: Do not fill the tank with hot liquid.
Do not let the level exceed the ‘MAX’ level line displayed on the front of the
tank.
Note: CF761/GG753 Only – If only one tank is to be filled, it must be the
left tank. To use left tank only, you just need to switch left stirring switch
ON (I position). Meanwhile, the righttank does not chill and the paddle does
not run.
Using the Dispenser
- Turn On the Power switch on the side of the dispenser
- Switch the stirring switchto the ‘On’ position [I].
- Once the liquid is sufficiently cooled, push the receptacle against the tap lever to dispense theliquid.
Note: Should the paddle encounter any resistance in the liquid, it will
reverse direction.
Adjusting the Beverage tank temperature
To adjust the temperature of beverage tank(s), lift up the plastic cover(s).
As CF761/GG753 has more than one tank, Tank 1 is the one on the left hand side
of the unit when looking from the front.
- Turn on the main switch on the right hand of the unit. The power indicator light (A) illuminates on the controller.
- To set the temperature of Tank 1, press button twice. The indicator light (1) on the top will illuminate and the current temperature will flash. Press the arrow buttons ( , ) to set the desired temperature. Then press button to confirm. (Temp range: 0°C – 10°C)
- Repeat above operations to set the temperature of tank 2/3, if desired (for CF761/ GG753).
- During use, the unit will automatically display the actual temperature of the tank for 2 seconds, with the corresponding tank indicator light illuminating.
- To switch off the cooling of a certain tank, press the corresponding tank button for 3 seconds. “OFF” will be displayed. To switch on cooling, press and hold the tank button again.
Emptying the Dispenser
Drain the dispenser by using the tap lever(s) to empty the tank(s).
Note: Do not drain the dispenser by tipping the appliance.
Cleaning, Care & Maintenance
- Switch off and disconnect from the power supply before cleaning.
- Warm, soapy water is recommended for cleaning. Cleaning agents may leave harmful residues. DO NOT wash the base unit, instead wipe the exterior with a damp cloth.
- Empty and clean the drip trays regularly.
- Unit should be de-scaled regularly. Note that scale may cause premature failure of the machine and it could invalidate your warranty.
Cleaning the Condenser
POLAR recommend the condenser is cleaned at least once a month.
Note: The condenser is the black (CF760) or silver (CF761/GG753) metal
grid behind the side panel.
To clean the condenser:
-
Unscrew the two screws from beneath the Temperature controller side panel.
-
Lift the side panel up and over Temperature controller to remove.
-
Clean the condenser with a soft cloth or brush.
WARNING: Take care when cleaning the condenser; sharp edges may cut. -
Replace the panel and two screws.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault | Probable Cause | Solution |
---|---|---|
The appliance is not working | The unit is not switched on | Check the unit is |
plugged in correctly and switched on
Plug or power cord is damaged| Replace plug or lead
Fuse in the plug has blown| Replace the fuse
Mains power supply fault| Check mains power supply
The dispenser is not cooling| Coolant leak| Consult a qualified technician
Fan motor failed| Consult a qualified technician
Airflow obstructed to the condenser| Increase the gap between appliance and
obstacles/heat source
Condenser is clogged| Remove side panels and clean condenser
The mixing paddles are not working| Mixing motor has failed| Consult a
qualified technician
The tank is leaking| Gasket problem| Check the gaskets and replace if
necessary
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be subject to change without notice.
Model| Voltage| Power
(W)| Current
(A)| Tanks| Capacity
(litres)| Refrigerant| Dimensions
H x W x D mm| Weight
(kg)
---|---|---|---|---|---|---|---|---
CF760| 220-240V- 50Hz| 290W| 1.9A| 1| 12| R290| 635 x 220 x 450| 20
CF761| 220-240V- 50Hz| 370W| 2.2A| 2| 24| R290| 635 x 420 x 450| 28
GG753| 220-240V- 50Hz| 450W| 2.55A| 3| 36| R290| 635 x 650 x 450| 36
Electrical Wiring
POLAR appliances are supplied with a 3 pin BS1363 plug and lead.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
- Live wire (coloured brown) to terminal marked L
- Neutral wire (coloured blue) to terminal marked N
- Earth wire (coloured green/yellow) to terminal marked E
This appliances must be earthed.
If in doubt consult a qualified electrician.
**** Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Disposal
EU regulations require refrigeration product to be disposed of by specialist
companies who remove or recycle all gasses, metal and plastic components.
Consult your local waste collection authority regarding disposal of your
appliance. Local authorities are not obliged to dispose of commercial
refrigeration equipment but may be able to offer advice on how to dispose of
the equipment locally.
Alternatively call the POLAR helpline for details of national disposal
companies within the EU.
Compliance
The WEEE logo on this product or its documentation indicates that the product
must not be disposed of as household waste. To help prevent possible harm to
human health and/or the environment, the product must be disposed of in an
approved and
environmentally safe recycling process. For further information on how to
dispose of this product correctly, contact the product supplier, or the local
authority responsible for waste disposal in your area.
POLAR parts have undergone strict product testing in order to comply with
regulatory standards and specifications set by international, independent, and
federal authorities.
POLAR products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or
transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to
press, however, POLAR reserve the right to change specifications without
notice.
DECLARATION OF CONFORMITY
Equipment Type | Model |
---|
G-Series Chilled Drinks Dispenser
G-Series Twin Tank Chilled Drinks Dispenser
G-Series Triple Tank Chilled Drinks Dispenser|
CF760 (-E & -A)
CF761 (-E & -A)
GG753 (-E & -A)
Application of Territory Legislation
& Council Directives(s)| Machinery Directive 2006/42/EC
(BS) EN 60335-1:2012 +A11:2014 +A13:2017
+A1:2019 +A14:2019
(BS) EN 60335-2-75:2004 +A1:2005 +A11:2006
+A2:2008 +A12:2010
(BS) EN 62233:2008
Electro-Magnetic Compatibility (EMC) Directive
2014/30/EU – recast of 2004/108/EC
(BS) EN IEC 55014-1:2021
(BS) EN IEC 55014-2:2021
(BS) EN IEC 61000-3-2:2019 +A1:2021
(BS) EN 61000-3-3:2013 +A1:2019 +A2:2021
Restriction of Hazardous Substances Directive
(RoHS) 2015/863 amending Annex II to Directive
2011/65/EU
| Electrical Safety
IEC 60335-1:2010 +A1:2013
+A2:2016
IEC 60335-2-75:2012 +A1:2015
EN 62233:2008
Electromagnetic Compatibility
AS/NZS CISPR 14.1:2021
| |
Producer Name| Polar|
I, the undersigned, hereby declare that the equipment specified above conforms
to the above Territory Legislation, Directive(s) and Standard(s).
Date
Signature
Full Name
Position
Producer Address
Ashley Hooper | Eoghan Donnellan | Brendan Denmeade |
---|---|---|
Technical & Quality Manager | Commercial Manager/ Importer | Commercial Manager/ |
Responsible Supplier
Fourth Way,
Avonmouth,
Bristol,
BS11 8TB
United Kingdom| Unit 9003,
Blarney Business Park,
Blarney,
Co. Cork
Ireland| 15 Bagdally Road, Campbelltown NSW 2560
+44 (0)845 146 2887
http://www.polar-refrigerator.com/
CF760_CF761_GG753_ML_A5_v10_2023/02/28
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>