CMP XO3 Del Ozone Spa Generator Instruction Manual
- June 12, 2024
- CMP
Table of Contents
CMP XO3 Del Ozone Spa Generator
Product Information
The product is the DEL Ozone Spa XO3, a spa sanitizing system. It is designed to dissolve ozone into the water circulation line of a spa to sanitize the water. The system must be installed and maintained properly to ensure safe and effective operation. Important safety information: It is crucial to read and follow all instructions provided in the installation, operating, and maintenance manual. Improper installation, adjustment, alteration, service, or lack of maintenance can cause injury or property damage. The DEL Ozone Spa XO3 can be used by children aged 8 years and above and individuals with reduced physical, sensory, or mental capabilities if they have been given supervision or instruction on safe usage. Children should not play with the appliance, and user maintenance should not be performed by children without supervision.
Product Usage Instructions
Section 1: Installation
-
Overview:
- Mount the DEL Ozone Spa XO3 in a space with at least 1 inch (25mm) clearance all around, except for the back mounting surface.
- The system must be mounted horizontally with the ozone tubing connection pointing down. Use both mounting flanges.
- Mount the system using the provided tabs on the DEL Ozone Spa XO3, spacing them 3.8 inches (96 mm) horizontally.
- Mount the system as high as possible within the protected equipment area.
-
Plumbing – DEL Mixing System:
-
For optimal dissolution of ozone into the water, install the
DEL mixing system in the water circulation line as shown in Figure 1. -
Connect the ozone generator, check valve, spa controller, ozone tubing, ozone flow, and spa supply pump according to the diagram.
-
-
Plumbing – Ozone Generator:
- Connect ozone compatible tubing (1/4 internal diameter) to the check valve on the DEL Ozone Spa XO3.
- Run the tubing to the ozone injector or appropriate vacuum source.
- If the ozone generator is mounted above the water line, tubing may be run directly to the vacuum source.
- If the ozone generator is mounted below the water line, run the tubing to a point above the water line and back down to the vacuum source.
Please refer to the complete user manual for more detailed instructions on installation and maintenance. Contact Customer Service for assistance with installation kits for different circulation systems.
THE COMPLETE MODERN SPA® C-M-P.COM/SPA-SANITIZERS
IMPORTANT SAFETY INFORMATION: READ AND FOLLOW ALL INSTRUCTIONS
Save these instructions. Leave manual with homeowner after installation.
Improper installation, adjustment, alteration, service, or lack of maintenance
can cause injury or property damage. Read the installation, operating, &
maintenance instructions thoroughly before installing or servicing this
equipment.
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
Read this manual completely before attempting installation. All permanent
electrical connections should be made by a qualified electrician. Follow all
applicable electrical codes.
DANGER Be sure the electrical power is shut OFF at the main circuit
breaker before installing the DEL Ozone® Spa XO3.
NOTICE If the DEL Ozone® Spa XO3 electrical connection is to be attached
to the spa controls, be sure the spa controls are protected by a Ground Fault
Circuit Interrupter (G.F.C.I.). If the DEL Ozone® Spa XO3 is connected to an
independent electrical supply, then a G.F.C.I. must be installed between the
DEL Ozone® Spa XO3 and the electrical supply.
WARNING To reduce the risk of electrical shock, if the power cord is
damaged, replace the entire unit immediately. The DEL Ozone® Spa XO3 must be
located or fixed so that it cannot fall into the spa.
NOTICE The DEL Ozone® Spa XO3 must be mounted indoors or sheltered, under
a cover, from natural elements (rain, sun, sprinklers). Mount the DEL Ozone®
Spa XO3 so that it is inaccessible to anyone in the spa.
NOTICE Plastic ozone supply tubing is available with the DEL Ozone® Spa
XO3. Never replace this tubing with metal tubing.
CAUTION Do not operate the DEL Ozone® Spa XO3 unless sufficient air flow
is being drawn through the unit.
WARNING Short term inhalation of high concentrations of ozone and long
term inhalations of low concentrations of ozone can cause harmful
physiological effects. Do not inhale ozone gas produced by this device.
NOTICE This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
SAVE THESE INSTRUCTIONS
SECTION 1
Installation
Overview
Achieve The Complete Modern Spa® by choosing sanitizing components that work
together, creating the best possible installation. The DEL Ozone Spa XO3 is a
high-end, modern ozone product for spas. The unit is compact, completely self-
contained and easy to install.
Mounting
- Mount DEL Ozone Spa XO3 in a space with at least 1 inch (25mm) clearance all around, except for the back mounting surface.
- The DEL Ozone Spa XO3 must be mounted horizontally with ozone tubing connection pointing down. Use both mounting flanges.
- Mount using the tabs are provided on the DEL Ozone Spa XO3, spaced 3.8 inches (96 mm) horizontally.
- Mount as high as possible within the protected equipment area.
Plumbing – DEL Mixing System
- For optimal dissolution of ozone into the water, install the DEL mixing system in the water circulation line as generally shown in Figure 1.
- For other circulation systems, CMP provides a wide range of installation kits. Contact Customer Service for assistance.
Plumbing – Ozone Generator
- Connect ozone compatible tubing (1/4” internal diameter) to the check valve on the DEL Ozone Spa XO3.
- Run tubing to the ozone injector or appropriate vacuum source.
- If the ozone generator is mounted above the water line, tubing may be run directly to the vacuum source.
- If ozone generator is mounted below the water line, run tubing to a point above the water line and back down to the vacuum source.
- Secure all tubing connections with hose clamps.
Electrical
- Verify that there is no power to the spa and connect the DEL Ozone Spa XO3 cord into the mating connector(s) on the spa control box.
- Where possible, route the DEL Ozone Spa XO3 power cord away from other electrical lines. Avoid routing the power cord parallel to any low-voltage signal wires.
Operation
- With the spa filled to the proper level, run the spa controller through several cycles.
- Verify that the green light on the DEL Ozone Spa XO3 turns on and off as required by the controller.
- Verify that gas is flowing into the injector (there should be no water in the tubing and very small bubbles at the return).
- Verify that water does not push past the check valve during any spa cycle.
- Check for and correct any leaks in the ozone tubing.
Maintenance
System Maintenance
- Ordering Information:
- To locate the dealer nearest you call 1-800-733-9060
- Be prepared with the following information:
- Name • Date Purchased
- Address • Dealer Name
- Model #
- Standard Replacement Parts List:
- Ozone Check Valve (7-2108-01)
- Ozone Tubing (7-0075)
- The ozone check valve and tubing should be replaced annually.
- Regularly inspect ozone supply tubing for cracks or wear. Also check to make sure no water is present between the check valve and the ozone generator. This indicates check valve failure. Replace the ozone check valve and tubing immediately.
WARNING Trace amounts of nitric acid may be present in the check valve or tubing and could be mildly corrosive. If condensation is present shut off the ozone generator and allow the moisture to be drawn out or dried up prior to servicing.
SUPPORT
SAVE THESE INSTRUCTIONS
Record Information on this System Below & Keep for Your Records
- Installer __
- System Purchased From _____
- Installation Date _____
- Serial Number ___
- Model Number __
CMP Customer Service & Tech Support
- Toll Free: 1-800-733-9060
- FAX: 770-632-7115
- support@c-m-p.com
Warranty
Warranty Questions
CMP, LLC
- 36 HERRING ROAD, NEWNAN, GA 30265
- WWW.C-M-P.COM/DEL