CLF-Lighting Poseidon Mirror User Manual

June 12, 2024
CLF LIGHTING

CLF Lighting logo POSEIDON MIRROR
MANUALCLF Lighting Poseidon Mirror V1.0 JUN 2023
WWW.CLF-LIGHTING.COM

DIMENSIONS IN MILLIMETERS

CLF Lighting Poseidon Mirror - DIMENSIONS

SAFETY INSTRUCTION

WARNING!
Read the safety precautions in this section before installing, powering, operating or servicing this product.

The following symbols are used to identify important safety information on the product and in this manual:

| | | | |
---|---|---|---|---|---
DANGER!
Satety hazard. Riskof  severs injury or death.| DANGER!
Hazardous voliage.  Risk of lethal orsevere:  electric shock.| WARNING!
Fire hazard| WARNING!
Bum hazard. Hot sutace.  Dot touch.| WARNING!
Wear protectve eyewear.| WARNING!
Rofer fo user mancal.

This product is for professional use only. Itis not for household use.
‘This product presents risks of severe injury or death due to fire and burn hazards, electric shock and falls.
Read this manual before installing, powering or servicing the fixture, follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture safely, please  contact your supplier.

PROTECTION FROM ELECTRIC SHOCK

| |
---|---|---

  • Disconnect the fixture from AC power before removing or installing any cover or part,
  • Aways ground (earth) the fixture electrically.
  • Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault (earth-fault) protection.
  • Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices.
  • Power input and throughput cables must be rated 20A minimu, have three conductors 1.5 mm? (16 AWG) ‘minimur conductor size and an outer cable diameter of 5 – 15 mm. Cables must be hard usage type (SJT or equivalent) and heat-resistant to 90°C  minimum.
  • Use only PowerCON TRUE 1€ cable connectors to connect to power input sockets. Use only PowerCON TRUE1 ® cable connectors to connect to power throughput sockets.
  • Isolate the fixture from power immediately ifthe power plug or any seal, cover, cable, or other component is damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power untilrepairs have been completed.
  • Refer any service operation not described in this manual to a qualified technician.
  • Socket outlets used to supply fixture fixtures with power or external power swiches must be located near the fixtures and easily accessible 5o that the fixtures can easily be disconnected from power.

PROTECTION FROM BURNS AND FIRE

|
---|---

  • The exterior of the fixture becomes hot during use. Avoid contact by persons and materials.
    Allow the fixture to cool for at least 5 minutes before handiing,

  • Keep all combustible materials (e.g. fabric, wood, paper) at least 1 metres away from the fixture.

  • Keep flammable materials well away from the fixture.

  • Ensure that there s free and unobstructed airflow around the fixture.

  • Donotilluminate surfaces within 8 metres of the fixture.

  • Donotattempt to bypass thermostatic switches or fuses.

  • Ifyou relay power from one fixture to another using power throughout sockets, do not connect more than fixtures in total to eachother in an interconnected chain.

  • Connect only other fixtures to fixture power throughout sockets.

  • Do not stick fiters, masks or other materials onto any optical component

  • Do not modify the fixture in any way not described in this manual.

PROTECTION FROM INJURY

|
---|---

  • Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when installed.
  • Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices they support.
  • Allow enough clearance around the head to ensure that it cannot collide with an object or another fixture when it moves.
  • Check that all external covers and rigging hardware are securely fastened.
  • Block access below the work area and work from a stable platform whenever installing, servicing or moving the fixture.
  • Do not operate the fixture with missing or damaged covers, shields or any optical component.

FIXTURE OVERVIEW

CLF Lighting Poseidon Mirror - Overview

INTRODUCTION

POWERFUL OUTDOOR MIRROR

  • 1P65 DUAL SIDED MIRROR MOVINGHEAD
  • CLEAR MIRROR AND 24 PCS SHAPED MIRROR
  • 540° PAN AND INFINITE TILT
  • 3 PRISMS (LINEAR, 4-FACET & 8-FACET)
  • MIRROR SHAKE EFFECT

USING FOR THE FIRST TIME
Warning! Read “Safety Information” before installing, powering, operating or servicing the fixture. Before applying power to the fixture:
Check that the local AC mains power source is within the fixture’s power voltage and frequency ranges.
See “Power cables and power plug” on page 6. Install a PowerCON TRUE1 ® power input connector power cable.

AC POWER

|
---|---

Warning! Read “Safety Information” starting on before connecting the fixtures to AC mains power.
Warning! For protection from electric shock, the fixture must be grounded (earthed). The power distribution circuit must be equipped with a fuse or circuit breaker and ground-fault (earth-fault) protection.
Warning! Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power.
Important! Do not insert or remove live PowerCON TRUE 1 ® connectors to apply or cut power, as this cause arcing at the terminals that will damage the connectors.
Important! Do not use an external dimming system to supply power to the fixture, as this may cause damage to the fixture that is not covered by the product warranty.
The fixture can be hard wired to a electrical installation if you want to install it permanently, or a power plug that is suitable for the local power outlets can be installed on the power cable.

POWER VOLTRGE
Warning! Check that the voltage range specified on the fixture serial number label matches the local AG mains power voltage before applying power to the fixture.
The fixtures accepts AC mains power at 100-240V nominal, 50/60 Hz. Do not apply AC mains power to the fixture at any other voltage than specified.

POWER CRBLES
Power input and throughput cables must be rated 16A minimum, have three conductors 1.5 mm* (16 AWG) minimum conductor size and an outer cable diameter of 5 – 15 mm. Cables must be hard usage type (SJT or equivalent) and heat- resistant to 90°C  minimum. In the EU the cable must be HAR approved or equivalent If you install a power plug on the power cable, install a grounding-type (earthed) plug that s rated 16A minimum. Follow the plug manufacturer’s instructions. Table 1 shows standard wire  color-coding schemes and some possible pin identification schemes; f pins are not dlearly identified. CLF Lighting Poseidon Mirror - Wire cloureRELAYING POWER T0 OTHER DEVICES
Warning! Do not connect more than five fixtures in total in one interconnected chain. Power can be relayed to another device via the PowerCON TRUE 1 ® throughput socket.
I you daisy chain the fixtures in a chain so that they all draw AC mains power via the first fixture, certain points must be respected:
Aheavy duty, three-conductor, 16 AWG or 1.5 mm2 cable with SJT or equivalent cable jacket must be used to connect the first fixture to AC mains power. PowerCON TRUE1 ® connectors must be used o draw AC mains power from the fixtures power throughput  socket and yellow PowerCON TRUE 1 ® connectors must be used to supply power at the fixture’s power input sockets.

A DMX 512 data link is required in order to control a fixture via DMX. The fixture has 5-pin XLR connectors for DMX data input and outpu The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+) Pins 4 and 5 in the 5-pin XLR connectors are not in use.

TIPS FOR RELIABLE DATA TRANSMISSION
To connect the fixture to data

  1. Connect the DMX data output from the controller to the 5-pin XLR connector of the nearest fixture.
  2. Connect the DMX output of the first fixture to the DMX input of the next fixture and continue connecting fixtures.

PHYSICAL INSTALLATION

Warning! The fixture must be either fastened to a flat surface such as a stage or wall, or clamped to a truss or similar structure in any orientation using a rigging clamp.
Warning! Always attach an approved safety cable to one of the safety cable attachment points on the base.
Do ot luminate surfaces within 6 meters of the fixture. Ensure that flammable materials (wood, fabric, paper, etc.) are minimum 1 meters from the fixture and allow a free airflow around the fixture.

FASTENING THE FIXTURE TO A FLAT SURFACE
The fixture can be fastened to a fixed flat surface that is oriented at any angle. Check that the surface can support at least 10 times the weight of allfixtures and equipment to be installed.
Warning! The supporting surface must be hard and flat or cooling may be blocked, which will cause overheating.
Fasten the fixture securely. Do not place it on unstable surfaces. Always attach a securely anchored safety cable to the safety cable attachment point.
Block access under the construction area. Work from a stable platform, hang the fixture on a truss with the arrow on the base towards the area to be illuminated. Tighten the rigging clamp.

QOUTDOOR IP-RATED FIXTURES
CLF products are applied to official classified IP norm levels. For this product the IP rate is IP65 when using the covers for the chassis parts. IP65 means according classified norm: shielded against dust and pressurized water from any side. Typical use for  outdoor rated stage events with normal weather acceptance. So no heavy rain, because then the water pressure over exceeds the IP norm, CLF Lighting Poseidon Mirror - IP norm

CONDENSATION/MOISTURE INSIDE HOUSING
Because of high humidity levels during production condensation can occur inside the housing. This is mostly visible on the coldest parts of the fixture, like the front glass or display. To prevent this problem we work with special conditioned areas for outdoor  fixtures. Because of the breathing air valves itis stil possible to get humidity inside the fixture. This will evaporate slowly. Do not put wet fixtures in a fightcase, this will help humidity enter the fixture.
FIXTURES TEMPERATURE SPECIFICATION
Make sure the fixture is used within its working temperature range. Outside this range we cannot guarantee correct operation,
TEMPORARY USRGE:
Stage event equipment is designed for temporary outdoor use. Materials are not designed for long-term exposure to heavy weather conditions. Rubber covers will be negatively affected by long-term UV exposure and should be checked by qualified service  technicians over time. Tightening screws too hard will negatively affect the IP-rating.

SETUP

Warning! Read “Safety Information” before installing, powering, operating the fixture.

CONTROL PANEL AND MENU NRVIGRTION
The onboard control panel and backit graphic display are used to adjust the DMX address, fixture settings (personality), service utiities See “Onboard control menus” for a complete list of menus and commands.

Using the control buttons :

  • Toenter the menu select [ENTER]
  • Press [UP], [DOWN], [LEFT] AND [RIGHT] to scroll within a menu or adjust values.
  • Toenteramenu, select a function or apply a selection, press [ENTER]
  • Toescape a function or move back one level in the menu structure, press [LEFT]

DMX ADDRESS SETTING

The DMX address is the first channel used to receive instructions from the controller. For independent control, each fixture must be assigned to a separate channel. The DMX address can be configured by using the DMX ADDRESS menu in the control panel.

  • NODMX: Display flashes and shows at ‘DMX: X’
  • DMX: Display backlight tums off and shows ‘DMX: V”
  • Thefixture is fully RDM ready. For RDM functions please refer to the ANSIESTA E1.20-2006 standard.

ONBOARD CONTROL MENUS

CLF Lighting Poseidon Mirror - CONTROL MENEUCLF
Lighting Poseidon Mirror - CONTROL MENEU 2

DMX PROTOCOL

CLF Lighting Poseidon Mirror - DMX PROTOCOL

CIRCUIT CONNECTION DIRGRAM

CLF Lighting Poseidon Mirror - CIRCUIT CONNECTION
DIAGRAM

SPECIFICATIONS

Power

Input voltage & rate| AC100-240V~, 50/60HZ
Nominal total power consumption (at nominal voltage 100v)| 60w
Typical current (at nominal voltage 100V)| 0.6A
Cos @| 0.95
Power plug type| Seetronic Powercon TRUE 1
Configuration
Pan| 540°
it| Endless
Heat management
MAX ambient temp (Ta max)|
MIN ambient temp (Ta min)|
MAX housing temp. (ta=40°C)|
Menu
Auto program| Manual program and Auto test program
Manual calibration| Service—calibration— function (0-255)
Factory calibration| Yes
Control
Control protocol| DMX512
DMX channel range| 8CH
RDM| Yes
WDMX| WDMX from Lumen Solution
ACN| No
5-pin
Data input (artnet, SACN)| No
Hardware
Interface| LCD Display
Software upload method| DMX, via special box
Installation
IP rating| 1P65
Orientation| Any
Housing
Safety attachment point| Bottom
Lock| Tilt lock
Physical
Net product weight| 15.5Kg
Machine dimensions – length| 372mm
Machine dimensions – depth| 242mm
Machine dimensions – height| 619mm
Carton size| 475’325’750mm
Gross weight| 18.9Kg
Accessories
Included items| Manual, Power cable, DMX cable, Safety cable
Approvals
Approved certifications| CE and RoHs.
Information
Article number| 160042

CLF Lighting logoCLF Lighting Poseidon Mirror - Icon
7WWW.CLF-LIGHTING.COM

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals