CLF LIGHTING TURBINE Powerful Touring Fan Instruction Manual

June 4, 2024
CLF LIGHTING

CLF LIGHTING TURBINE Powerful Touring Fan LOGO

CLF LIGHTING TURBINE Powerful Touring Fan

MACHINE OVERVIEW

CLF LIGHTING TURBINE Powerful Touring Fan 1

  1. LCD display
  2. Fan grill
  3. 3-pin OMX socket
  4. 5 pin OMX socket
  5. Grip
  6. Fan protector
  7. Adjusting knob
  8. PowerCon input
  9. PowerCon output

SAFETY INSTRUCTION

The following symbols are used to identify important safety information on the product.

DANGER
Safety hazard. Risk of severe injury or death DANGER
Hazardous voltage
Risk of lethal or severe electric shock. WARNING
Fire hazard WARNING
LED light Burn hazard
Hot emission
Risk of surface. Do not eye injury. touch WARNING
Wear protective eyewear. WARNING
Refer to user manual.

USING FOR THE FIRST TIME

This product is for professional use only. It is not for household use. This product presents risks of severe injury or death due to fire and burn hazards, electric shock and falls.
before installing, powering or servicing the fixture, follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture safely, please contact your supplier.

PROTECTION FROM ELECTRIC SHOCK

  • Disconnect the machine from AC power before removing or installing any cover or part and when not in use
  • Always ground (earth) the fixture electrically.
  • Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault earth fault protection.
  • Before using the machine check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices.
  • Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm 16 AWG minimum conductor size and an outer cable diameter of 5 – 15 mm .
  • Cables must be hard usage type (SJT or equivalent) and heat-resistant to 90° C minimum.
  • Use only PowerCON® cable connectors to connect to power input sockets.
  • Use only PowerCON cable connectors to connect to power through put sockets.
  • Isolate the machine from power immediately if the power plug or any seal, cover, cable, or other component is damaged, defective, deformed, wet or showing signs of overheating.
  • Do not reapply power until repairs have been completed.
  • DO NOT EXPOSE THE FIXTURE TO RRIN OR MOISTURE
  • CLF Turbine has an IP20 rating, indoor use only.

PROTECTION FROM BURNS RNO FIRE

  • Do not operate the machine if the ambient temperature Ta exceeds 45 ° C.
  • The exterior of the machine becomes hot during use.
  • Avoid contact by persons and materials.
  • Allow the machine to cool for at least 1 0 minutes before handling.
  • Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm away from the nozzle
  • Keep flammable materials well away from the machine
  • Ensure that there is free and unobstructed airflow around the machine
  • Do not place objects within 200 mm of the machine
  • Do not attempt to bypass thermostatic switches or fuses.
  • If you relay power from one machine to another using power throughput sockets, do not connect more than machines in total to each other in an interconnected chain.
  • Connect only other machines to fixture power throughput sockets.
  • Do not connect any other type of device to these sockets.
  • Do not connect any other type of device to these sockets.
  • Do not stick filters, masks or other materials onto any optical component.
  • Do not modify the machine in any way not described.
  • Do not connect machine to a dimme

PROTECTION FROM INJURY

  • Fasten the fixture securely to a fixed surface or structure when in use.
  • The fixture is not portable when installed.
  • Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices they support.
  • Allow enough clearance around the head to ensure that it cannot collide with an object or another fixture when it moves.
  • Check that all external covers and rigging hardware are securely fastened.
  • Block access below the work area and work from a stable platform whenever installing, servicing or moving the machine.
  • Do not operate the machine with missing or damaged covers, shields or any optical component.

RC POWER

POWER VOLTAGE

Check that the voltage range specified on the machine serial number label matches the local AC mains power voltage before applying power to the fixture. The machine accepts AC mains power at 100-240 V nominal. 50/60 Hz. Do not apply AC mains power to the machine at any other voltage than specified.

POWER CABLES

Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm 2 16 AWG minimum conductor size and an outer cable diameter of 5 – 15 mm. Cables must be hard usage type SJT or equivalent and heat resistant to so·c minimum. In the EU the cable must be HAR approved or equivalent. If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 20 A minimum. Follow the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes and some possible pin identification schemes; if pins are not clearly identified, or if you have any doubts.

Wire color EU models| Wire color US models| Conductor| Symbol| Screw US
---|---|---|---|---
Brown| Black| Live| L| Yellow or Brass
Blue| White| Neutral| N| Silver
Yellow / green| Green| Ground earth| | Green

ORTALINI

A DMX 512 data link is required in order to control a machine via DMX. The machine has 3 & 5-pin XLR connectors for DMX data
input and output. The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot(+) Pins 4 and 5 in the 5-pin XLR
connectors are not used.

TIPS FOR RELIABLE DATR TRANSMISSION

To connect the machine to data

  1. Connect the DMX data output from the controller to the closest machines male 3 & 5 pin XLR DMX input connector.
  2. Connect the DMX output of the machine closest to the controller to the DMX input of the next machine and continue connecting machines output to input.

PHYSICAL INSTALLATION

Warning
The machine must be either fastened to a flat surface such as a stage or wall, or clamped to a truss or similar structure in any orientation using a rigging clamp warning.At all times machine can cause injury or damage it if falls, attach an approved safety cable to one of the safety cable attachment points on the base  overview. Check that all surfaces more far aways then a minimum of 200 mm. from the machine, that combustible materials wood, fabric, paper, etc.) are minimum 100 mm. from the nozzle, that there is free airflow around the machine and that there are no flammable materials nearby.

FRSTENING THE MRCHINE TO R FLRT SURFRCE

The machine can be fastened to a fixed flat surface that is oriented at any angle. Check that the surface can support at least 10 times the weight of all machines and equipment to be installed on it. The supporting surface must be flat otherwise the air vents in the base may be blocked, which will cause overheating. Fasten the machine securely. Do not place it on a surface or leave it where it can be moved or can fall over. Attach a securely anchored safety cable to the safety cable attachment point. If the machine is installed in any location where ii may fall and cause injury or damage if the primary attachment fails

  • Block access under the work area. Working from a stable platform.
  • Secure the machine with a secondary attachment such as an approved safety cable that is rated for the weight of the machine using one of the attachment points at the edges of the base.
  • Do not use any other part of the machine as a safety cable attachment point.

OPERATING INSTRUCTIONS

  1. After checking that all the parts are intact and complete, position the machine on a flat surface.
  2. Connecting the power cord. Before power on, make sure it is connected with the rated voltage.
  1. MENU button: Press “menu” button to enter the page “ADDR”
  2. UP button: Increase the relevant value of each page
  3. DOWN button: Decrease the relevant value of each pag
  4. ENTER button: Enter or exit each page.
  • MENU: Scroll through setting menu
  • UP:Increase, multiplex TIMER button
  • DOWN:Decrease, multiplex VOLUME button
  • ENTER:In/Out, multiplex stop button

Press MENU button to switch different pages, 5 pages in total

  1. Ready To Work: The machine is ready to work
  2. DMX512 Address: The DMX address can be set up from 1 to 512
  3. Volume out: Set the haze fog output from 1 – 100% under Volume mode
  4. Vllireless Set: Set the wireless function ON or OFF
  5. Language: Select the language saved by Enter

OMX CHANNELS

Channel Function Value Percentage Remark
CH 1 FAN output 006- 255 0-100% 000 – 009 = OFF

EXPLODED VIEW

CLF LIGHTING TURBINE Powerful Touring Fan 11

No. Desription Part number CLF
Handle CLF-70-002
Handle fixing plate CLF-70-003
Safety eye CLF-70-004
Plastic ring for safety eye CLF-70-005
Fan cover front CLF-70-006
Knob CLF-70-007
Base (stand) CLF-70-008
5-pin OMX PCB (maleffemale) CLF-70-009
PowerCON output socket white CLF-70-010
10 PowerCON input socket blue CLF-70-011
11 Main PCB/ power supply CLF-70-012
12 Wireless board CLF-70-013
13 over base CLF-70-014
14 Display sticker CLF-70-015
15 LCD support plate CLF-70-016
16 Plastic display support CLF-70-017
17 Display PCB CLF-70-018
18 3-pin OMX PCB (male/female) CLF-70-019
19 Quick lock pedestal CLF-70-020
20 Quick lock cover CLF-70-021
21 Brackets 2pcs each fixture CLF-70-022
22 Name plate CLF-70-023
23 Cable gland base CLF-70-024
24 Power cable base / fan CLF-70-025
25 Fan housing CLF-70-026
26 Fan CLF-70-027
27 Fan motor cover CLF-70-028
28 Schuko-PowerCON connection cable 3×1,5mm2, 1,8 mtr length 911140
29 Wireless remote CLF-70-029

SPECIFICATIONS

Power 150W
Voltage I frequency AC1DOV – 240V – 50/60Hz
Fuse 2A/250V
Stand by power consumption <15W
AC power input PowerCON
DMX data in/out 5 pin & 3 pin locking XLR
Netto weight 11kg
Size 443x250x470mm
Control DMX
Channel 1 channel
Output 1350R/min to 1S00R/min Airflow 0Pa m3/hour ±10%: 2200
Settings and addressing Control panel with backlit character LCD
Protocol USITT DMX512-A
Color Black
Housing High strenght die casting aluminium and metal
Protection rating IP20
Orientation Floor & hanging
Min distance to combustable materials 300mm from machine
Min distance to iluminated surfaces 400mm from machine
Wireless remote None
Air angle 0° to 270°

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CLF LIGHTING User Manuals

Related Manuals